Ade ZW50-210903 Bruksanvisning

Ade Vågen ZW50-210903

Läs nedan 📖 manual på svenska för Ade ZW50-210903 (24 sidor) i kategorin Vågen. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/24
OPERATING INSTRUCTIONS
Electronic counting scale
ZW50 Series Counting Scale
ZW50-210903-Rev006- -UM en
2 ZW50- -Rev006-210903 UM- en
Contents
1. Applications ............................................................................................................... 3
2. Warnings ................................................................................................................... 3
3. Scope of Supply ......................................................................................................... 4
4. Setting Up the Scale .................................................................................................. 4
4.1 Setting Up the Local Scale ......................................................................................... 4
4.2 Setting Up the Remote Scale ..................................................................................... 5
5. Display Overview ....................................................................................................... 6
6. Key Functions ............................................................................................................ 7
7. Displays ..................................................................................................................... 8
7.1 Weight Display (WEIGHT) ......................................................................................... 8
7.2 Unit Weight Display (UNIT WEIGHT) ......................................................................... 8
7.3 Count Display (COUNT) ............................................................................................ 9
7.4 Battery Charge Indicator ............................................................................................ 9
8. Operation ..................................................................................................................10
8.1 General .....................................................................................................................10
8.2 Switching On the Scale .............................................................................................10
8.3 Zeroing the Display ...................................................................................................10
8.4 Taring .......................................................................................................................10
8.5 Determining / Entering the Unit Weight .....................................................................11
8.6 Piece Counting .........................................................................................................13
8.7 Check Weighing ........................................................................................................13
8.8 Summation Memory ..................................................................................................14
8.9 PLU (Product Look Up) .............................................................................................14
9. Parameters ...............................................................................................................17
10. RS-232 Data Output .................................................................................................19
11. Care, Maintenance, and Warranty ............................................................................19
11.1 Care and Cleaning ....................................................................................................19
11.2 Error Messages ........................................................................................................19
11.3 Storage and transportation conditions .......................................................................20
11.4 Disposal ....................................................................................................................20
11.5 Warranty ...................................................................................................................20
12. Technical Data ..........................................................................................................21
13. Declaration of Conformity .........................................................................................22
ZW50- -Rev006- - 3210903 UM en
1. Applications
This symbol means: “Observe operating instructions.” Read these operating
instructions carefully and observe the information contained therein. Keep
these operating instructions handy for future reference.
The ZW50 series digital counting scale oers accurate, fast, and versatile counting and check
weighing and is intended for use in areas not regulated by law.
This scale features an auxiliary connection, enabling you to connect an additional weighing
base (e.g., platform, pallet, or oor scale) for weighing heavier weights or counting larger quan-
tities.
The ZW50 series comprises four models with capacities of up to 30 kg.
All models are equipped with stainless steel weighing platforms and ABS plastic housings.
All scales feature sealed keypads with color-coded membrane switches and three large,
easy- -read liquid crystal displays (LCD). The LCD display has a backlight that can be to
enabled or disabled.
All scales have an automatic zero function, an acoustic alarm for preset weights, automatic
taring, preset taring, and a summation memory that allows storing and recalling total quan-
tities.
The scale oers a memory capacity for 100 unit weight items (PLU), the tare function, and
the alphanumeric description of frequently used items.
The scale oers a choice between kg and lbs units.
The ZW50 series is tted with a bidirectional RS232 data interface, enabling you to connect
a PC or printer.
The scale can be powered from a 230 V power outlet or a 6 V 4 Ah rechargeable battery.
2. Warnings
The scale complies with the directives and standards for electrical equipment, electromagnetic
compatibility, and the stipulated safety requirements. Improper use of the scale may cause
personal injury and material damage.
Read these operating instructions carefully before using the appliance for the rst time. This
will prevent damage to the appliance. Keep the operating instructions in a safe place.
Observe the following instructions to ensure safe and smooth operation of the
scale:
Never expose the scale to extreme temperatures, direct sunlight, or other
sources of heat. This may adversely aect the liquid crystal display.
Electronic scales must not come into contact with water. Only use the scale
in a dry place. Wipe the scale with a damp cloth. If you accidentally spill
water onto the scale, switch it o immediately and let it dry thoroughly.
Never use harsh or abrasive cleaning agents to clean the scale. They can
damage the shiny surface of the housing and make it more prone to soiling.
Before connecting the included mains cable to the scale, ensure the voltage
on the rating plate corresponds to that of your local power grid. Connect the
mains cable to the local mains supply.
Never attempt to open the scale! If you have any problems, contact the cus-
tomer service of your authorized dealer.