OPENING THE SAFE WITH ACCESS KEY
For Large & Standard Keypad Depository Safe
1. To expose the key access, remove logo plate screws with
provided Allen wrench
2. Insert access key into key access, and turn clockwise to open
For Compact Keypad Depository Safe
1. To expose the key access, gently lift off the key cover
2. Insert access key into key access, and turn clockwise to open
NOTE: Store keys in a secure place. NOT inside of the safe
BATTERIES
1. Remove battery cover on the inside of the safe door
2. Insert 4 new AA batteries into the battery compartment and
pay attention to the polarity of the batteries
3. Replace compartment cover
CREATING PERSONAL PIN CODES
Safe retains only two 3-8 digit pin codes
1st Personal Pin Code
1. With safe open, press and release the initialization button
located on the inside of the safe door. Yellow indicator light will
be on.
2. On the key pad input your 3-8 digit pin code and press and
release either "A" or "B" to confirm. Yellow indicator light will
turn off.
2nd Personal Pin Code
1. On the key pad press and release “0” twice. Press and
release the initialization button located on the inside of the
safe door. Yellow indicator light will be on.
2. On the key pad input your 3-8 digit pin code and press and
release either "A" or "B" to confirm. Yellow indicator light will
turn off.
TESTING PERSONAL PIN CODES
1. With safe door open, and the handle/lock knob in the lock
position. Enter in 1st personal pin code on the key pad and
press and release either "A" or "B" to confirm.
Successful Save
- You will hear 2 short beeps
- The green indicator light will flash
- Move handle to the right to retract bolts
Unsuccessful Save
- You will hear 3 short beeps
- Handle will not move and bolts will stay extended
- Repeat steps CREATING PERSONAL PIN CODES
2. To test 2nd personal pin code, enter in 2nd personal pin code
on the key pad and press and release either "A" or "B"
to confirm. See “Successful Save” and
“Unsuccessful Save” above
3. Test a pin code that is not registered to make sure the safe
does not open to complete testing process
OPENING & CLOSING SAFE WITH PERSONAL PIN
CODES
OPEN:
1. On the key pad enter in either of your 3-8 digit pin codes and
press and release either "A" or "B" to confirm.
2. Turn the handle/lock knob to the unlock position and pull the
safe door open
NOTE
After entering pin, you have 5 seconds to turn the knob before
the mechanism re-locks automatically
CLOSE:
To close safe, close door and turn knob to the lock position
LOCK OUT
Lock out mode is activated when the wrong personal pin code is
entered
- 4 consecutive times, Lock out mode will last 20 seconds
- 6 consecutive times, Lock out mode will last 5 minutes
CHANGING PERSONAL PIN CODES
Follow steps in “CREATING PERSONAL PIN CODES”
Parts of the Control Panel
C. Indicator Lights
D. Key Pad
A. Handle
B. Logo Plate and Key Access
Parts of the Control Panel
C. Indicator Lights
D. Key Pad
A. Lock Knob
B. Key Cover and Key Access
Parts of the Inside of the Safe Door
E. Initialization Button F. Battery Compartment
A
F
B
C D
C
B
D
E
WARNING: Avoid leaving door open and unattended; it will
allow unauthorized individuals to reprogram the safe,
gaining full access to the safe and contents.
User Manual For Depository Safe
1 2 3 A
4 5 6 0
7 8 9 B
A
Large & Standard Keypad Depository Safe
Compact Keypad Depository Safe
1 2 3 A
4 5 6 0
7 8 9 B
* Actual models may vary
L
o
c
k
P
o
s
i
t
i
o
n
U
n
l
o
c
k
P
o
s
i
t
i
o
n
L
o
c
k
P
o
s
i
t
i
o
n
U
n
l
o
c
k
P
o
s
i
t
i
o
n
See reverse side for more information 10/12
BC250
© 2012 BARSKA
®
1721 Wright Ave | La Verne, CA 91750 | USA
(t) 888.666.6769 | (f) 909.445.8169 | www.barska.com
BARSKA warrants this new safe to be free of original defects in
material and/or workmanship under normal use for a period of
twelve (12) months from the date product is received by purchaser.
This warranty does not include damage caused by improper
installation or maintenance. Damage from misuse, abuse, accident
(such as dropping), normal wear and tear, excessive fire, flood, or
acts of nature. Damage from service or repairs other than those
performed by BARSKA. Labor, cost and shipping charges for the
removal and replacement of defective parts beyond the initial
twelve-month warranty period. All transportation and shipping
charges. Removing or altering the seal under any circumstances
will automatically void the warranty.
This warranty is limited to original purchaser and is not transferable.
This warranty applies only to products purchased in the United
States.
Please email info@barska.com or call 1.888.666.6769 for Return
Merchandise Number (RMA#) before any returns. The RMA
number must appear on the outside of the shipping package.
Product must be packed carefully and sturdily in its original
packaging to prevent damage in transit and returned freight
pre-paid to:
BARSKA OPTICS
Repair Department
1721 Wright Avenue
La Verne, CA 91750
Please include all of the following when returning BARSKA
products for service and/or replacement:
1. Please write your complete details
(Name, Address, Telephone #, E-mail address, RMA#, etc.)
2. Purchase receipt or Proof of Purchase. (Original/Copy)
3. A brief explanation of the defect
4. A Check/Money Order of cover inspection, shipping and
handling. Charges are as follows:
Large Keypad Depository Safe = $60.00
Standard Keypad Depository Safe = $40.00
Compact Keypad Depository Safe = $40.00
*Please allow 6-8 weeks for delivery.
BARSKA will examine and test returned product and repair or
replace defective part(s) or units with new part(s) or a new unit if
necessary within the warranty period. Purchaser is required to remit
above charges to BARSKA for return shipping and handling at time
product is returned. If repair is required after warranty period
expiration, purchaser will be charged for replacement parts and
return shipping.
BARSKA® Optics shall not be liable for any consequential,
incidental and/or contingent damages whatsoever. We will not pay
shipping, insurance or transportation charges from you to us, or any
import fees, duties and or taxes. This warranty supersedes all
previous BARSKA® Optics warranties.
SAFES
1 YEAR LIMITED WARRANTY
9/12BC247
LOW BATTERY WARNING
After entering correct personal code and the green and red indicator
lights are flashing this indicates that the batteries are low.
Follow steps in “BATTERIES”
NOTE
Safe may still be opened in low battery state depending on battery
voltage. If safe cannot be opened please use emergency key.
All registered pin codes remain stored
CARE AND MAINTENANCE
- If necessary use a damp cloth to clean the safe. DO NOT use
chemicals or cleaning agents
- Keep liquids away from the control panel. Spills on the control
panel will cause damage and possibly electric shock
- Secure safe in a proper area to prevent it from falling and
causing damage or injury
- DO NOT over stuff the contents of the safe, it can damage the
motor mechanism or the contents
- DO NOT disassemble the product. For all repairs and maintenance,
contact BARSKA Customer Service
- DO NOT place emergency keys inside of safe
User Manual For Depository Safe

Produktspecifikationer

Varumärke: Barska
Kategori: Valv
Modell: AX11934

Behöver du hjälp?

Om du behöver hjälp med Barska AX11934 ställ en fråga nedan och andra användare kommer att svara dig




Valv Barska Manualer

Valv Manualer

Nyaste Valv Manualer