CP34, CP35 AND CP37 SERIES
HB0078
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 12 AND 13.
READ AND SAVE THESE INSTRUCTIONS
BEST; Hartford, Wisconsin www.BestRangeHoods.com 800-558-1711
To register your product online or for additional information visit www.BestRangeHoods.com
SV08544 rev. 11
! !
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturers guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn power pack ON when cooking at high heat or
when flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your power pack motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the power pack serviced.
5. The minimum hood distance above cooktop must not be less
than 24”. A maximum of 30” above cooktop is recommended for
best capture of cooking impurities.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. This product is equipped with a thermostat which may start
blower automatically. To reduce the risk of injury and to prevent
power from being switched on accidentally, switch power off at
service panel and lock or tag service panel.
9. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
10. To reduce the risk of fire and electrical shock, the Best models
CP34, CP35 and CP37 Series should only be installed with
their own built-in blowers. Other blowers cannot be substituted.
11. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
!
3
HL0122
- CP34, CP35 AND CP37 POWER PACK SYSTEMS -
M 634 644ODEL OR
(R )OOF CAP
M 643ODEL
(8” R )OUND WALL CAP
M 418 ODEL
(10” R OUND
ADJUSTABLE ELBOW )
M 410 ODEL
(10” R OUND DUCT
— 2 )FT. SECTIONS
10” ROUND VERTICAL
IN LINE DAMPER SUPPLIED WITH- (
DUAL BLOWER POWER PACK )
MODEL 437
(HIGH CAPACITY
ROOF CAP)
MODEL 441
(10’ ROUND
WALL CAP)
10” ROUND ADAPTER
( SUPPLIED WITH DUAL BLOWER
POWER PACK )
DUAL BLOWER CFM (1200 )
S 48” UPPLIED WITH WIDTH
POWER ONLY PACK
S INGLE BLOWER CFM (600 )
S 30’, 36 UPPLIED WITH AND
42” WIDTH POWER PAC K ONLY
*300 CFM AIR FLOW REDUCER
INTEGRATED ON ODEL CP34 M
CP37
POWER PACK
CP34
POWER PACK*
CP35
POWER PACK
A /DAPTER DAMPER
8” ( ROUND SUPPLIED WITH
SINGLE BLOWER POWER PACKS )
8” ROUND
STANDARD DUCT
8” R OUND
ADJUSTABLE ELBOW
6
6. REMOVE GREASE DRIP RAIL
A. Lift grease drip rail to disengage it from the bottom
panel.
B. Slide grease rail all the way to the left or right ( ) and
lift the opposite end to disengage the other end from
the bottom panel (). Remove it from the power pack
and set aside for later use.
7. REMOVE BOTTOM PANEL
Using a Phillips screwdriver, remove both bottom panel retaining
screws and set aside.
8. REMOVE KNOCK-OUT OPENING
From inside the power pack, remove the wiring cover by removing 2 retaining screws and set
aside. Punch out the electrical knockout hole on top of the power pack. Install the wire clamp
(included in parts bag).
9. INSTALL ADAPTER/DAMPER (CP34 AND CP35 MODELS)
Using 4 no. 8 x 3/8” screws from parts bag, assemble the adapter/damper on the top of the power
pack. To ensure proper opening of the dampers, remove shipping tape if present. Seal all joints
with metal foil duct tape to eliminate air leaks.
HD0291
A
HD0292
B
Disassemble bottom panel from power pack and set aside.
HO0110
RETAINING SCREW LOCATIONS
HO0111 S IDE VIEW
HR0027
HJ0016
MOUNTING SCREW LOCATIONS
8
12. REMOVE BLOWER(S)
In order to ease the power pack alignment with existing ductwork, unplug and disassemble the blower(s) from the power pack before
installing the custom hood.
For each blower, using a 5/16” socket, remove all blower mounting screws from the inner top of the
power pack front and rear brackets. Set the screws aside.
HE0085
Unplug the blower(s)
CP34 CP35 MAND ODELS
HD0269
L EFT SIDE MOUNTING
SCREWS LOCATION
Using a 5/16” socket, remove all blower mounting
screws from the inner top of the power pack. Set
the screws aside.
HD0282
R IGHT SIDE
MOUNTING SCREWS
LOCATION
Slide the blower to disengage its flange from the
retaining bracket. Set the blower aside.
HD0270
CP37 MODEL
For each blower, slide it to disengage its flanges from the retaining brackets. Set the blowers aside.
BLOWERS FRONT BRACKET
BLOWERS REAR BRACKET
HD0297
HD0298
10
14. REINSTALL BLOWER(S) (CONT D’ )
Plug the blower(s) in.
HE0085
A LL MODELS
15. REINSTALL BOTTOM PANEL
Lift the bottom panel and engage the power pack metal tabs in
bottom panel slots, as shown in details and below.A B
Secure the bottom panel to the power pack using its screws
previously removed in step 7.
HO0110
RETAINING SCREW LOCATIONS
A B
HO0112
S IDE VIEW
16. REINSTALL GREASE DRIP RAIL
A. Insert one end of grease rail in power pack side ()
while lifting the other end over the bottom panel
edge ( ).
B. Center the grease drip rail over the bottom panel
edge and flip it to snap in place.
HD0291
B
HD0292
A
11
17. REINSTALL BAFFLE FILTERS
CAUTION
Remove protective plastic film covering filters before installing them.
It is recommended to install side filters first and finish with center one(s).
1. Insert one end of the filter into the upper channel
of the power pack.
2. Raise the other end toward the inside of power
pack and insert in the grease drip rail of the
power pack.
1
HD0299
2
18. LIGHT BULBS
This power pack requires shielded halogen lamps (120 V, 50 W, MR16 with GU10 base or PAR16 with GU10 base), included.
NOTE: Before using lamps, remove shipping tape on them (if present).
1. Install the lamps by placing the bulb leads into their grooves in the socket.
2. Gently push upwards and turn clockwise until secure.
To remove lamps, gently push upwards and turn counterclockwise to disengage bulb leads
from their grooves.
NOTE: To ease removal of the bulbs, use a rubber dishwashing glove or use suction cup
tool available from Best. Contact Best Customer Service at 1-800-558-1711 to order
suction cup tool, part no. 99526707.
WARNING
!
!
!
!!
Do not touch lamps during or soon after operation. Burns may occur. In order to prevent the risk of personal injury,
only install shielded halogen lamps. Also, never install a cool beam, a dichroic lamp, a lamp not suitable for use in
recessed luminaires or identified for use in enclosed fixtures.
1 2
HO0090

Produktspecifikationer

Varumärke: Best
Kategori: Fläktkåpa
Modell: 5810005
Färg på produkten: Wit
Vikt: 2950 g
Bredd: 700 mm
Djup: 700 mm
Höjd: 220 mm
Förpackningens vikt: 5520 g
Förpackningens bredd: 720 mm
Djuppackning: 715 mm
Förpackningshöjd: 230 mm
Husmaterial: Aluminium, Silicone
siffra: 1
Kompatibilitet: Mikrotik mANT30

Behöver du hjälp?

Om du behöver hjälp med Best 5810005 ställ en fråga nedan och andra användare kommer att svara dig




Fläktkåpa Best Manualer

Fläktkåpa Manualer

Nyaste Fläktkåpa Manualer