EVPK90 Linear Extractor
Manual for Installation, Use and Maintenance
2
Important
The manufacturer cannot be held responsible for injuries or losses caused by incorrect use or installation of this product.
Please note that the manufacturer reserves the right to invalidate the guarantee supplied with this product following incorrect
installation or misuse of the appliance or use in a commercial environment.
This appliance is not designed to be used by people (including children) with reduced physical, sensorial or mental capacity, or
who lack experience or knowledge about it, unless they have had supervision or instructions on how to use the appliance by
someone who is responsible for their safety.
Under no circumstances should any external covers be removed for servicing or maintenance except by suitably qualied
personnel.
Appliance information:
Please enter the details on the appliance rating plate below for reference, to assist CDA Customer Care in the event of a fault with
your appliance and to register your appliance for guarantee purposes.
Appliance Model
Serial Number
CE Declarations of Conformity:
This appliance has been manufactured to the strictest standards and complies with all applicable legislation, including Gas safety,
Electrical safety (LVD) and Electromagnetic interference compatibility (EMC).
IMPORTANT INFORMATION FOR CORRECT DISPOSAL OF THE PRODUCT IN ACCORDANCE WITH EC DIRECTIVE
2002/96/EC.
At the end of its working life, the product must be taken to a special local authority waste collection centre or to a dealer
providing appliance recycling services.
Disposing of a household appliance separately avoids possible negative consequences for the environment and health. It also
enables the constituent materials to be recovered, saving both energy and resources. As a reminder of the need to dispose of
household appliances separately, the product is marked with a crossed-out wheeled dustbin.
Please note:
Under no circumstances should the extractor be connected to any gas ventilation system, ue system or hot air
ducting system.
Do not vent the extractor into an attic or loft space.
Only house the extractor in rooms with adequate ventilation. Remember that the extractor is powerful and whatever air is
extracted needs to be replaced.
Do not tile the extractor in. It should be removable for service or maintenance.
Do not use silicone sealant to secure the hood to the wall.
You must be able to isolate the extractor from the mains electrical supply after installation.
Steam cleaners must not be used when cleaning this appliance.
The performance of your extractor will vary depending on a number of factors. These include: type of extraction, length of
ducting, room volume, ventilation available and cleanliness of the lters.
3
Using your Extractor
For best performance, you should switch on the extractor 15 minutes before starting to cook and leave it to run for approximately
15 minutes after the end of cooking.
Control Panel
A - Light key
B - Decrease speed key
C - Display
D - Increase speed key
E - Timer key
To switch the extractor light on and o
Touch key A.
To switch on the extractor
Touch either key B or D. The appliance will switch on at the rst speed.
To increase the speed touch key D.
To switch the extractor o, touch and hold key B for two seconds when the extractor is working at higher speeds, or touch
key B at speed one.
The intensive function
The extractor is equipped with an intensive function which runs for ten minutes before returning to the previous selected
speed. To activate the intensive function, touch key D at speed three. The display will blink whilst the intensive function is on.
The timer
The extractor is equipped with a timer that allows the extractor to run for 15 minutes before switching o automatically.
To activate the timer, touch key E. The display will ash a decimal point when the timer is on.
Please note
The timer cannot be activated when the intensive function is on.
The clean air function
The extractor is equipped with a clean air function that switches on the motor for ten minutes every hour at speed one.
To activate the clean air function, touch key E for two seconds when the appliance is o. To return to normal function, touch
either key B or D. To switch o the clean air function, touch key E. The display C will light up in sections whilst the motor is
running, and will show the letter C during the fty minutes when the motor is not running.
Fig. 1
A B C D E

Produktspecifikationer

Varumärke: CDA
Kategori: Fläktkåpa
Modell: EVPK90

Behöver du hjälp?

Om du behöver hjälp med CDA EVPK90 ställ en fråga nedan och andra användare kommer att svara dig




Fläktkåpa CDA Manualer

CDA

CDA CCA52BL Bruksanvisning

16 September 2024
CDA

CDA EVP62SS Bruksanvisning

14 September 2024
CDA

CDA EGA60BL Bruksanvisning

14 September 2024
CDA

CDA EVPK90 Bruksanvisning

4 September 2024
CDA

CDA EKN70BL Bruksanvisning

3 September 2024
CDA

CDA EVP121SS Bruksanvisning

3 September 2024
CDA

CDA EXA80SI Bruksanvisning

3 September 2024
CDA

CDA EDD62BL Bruksanvisning

2 September 2024
CDA

CDA ECH63BL Bruksanvisning

1 September 2024
CDA

CDA ECH101SS Bruksanvisning

31 Augusti 2024

Fläktkåpa Manualer

Nyaste Fläktkåpa Manualer