Celestron C6-NGT Computerized Bruksanvisning
Läs nedan 📖 manual på svenska för Celestron C6-NGT Computerized (8 sidor) i kategorin Teleskop. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/8

NexStar Communication Protocol
This document describes the serial commands supported by the Celestron NexStar hand control. This information
applies to the NexStar GPS, NexStar GPS-SA, NexStar iSeries, NexStar SE Series, NexStar GT, CPC, SLT, Advanced-
GT, and CGE mounts.
Communication to the hand control is 9600 bits/sec, no parity and one stop bit via the RS-232 port on the base of the
hand control.
Note: the GT hand control prior to version 104.0 should be treated as version 1.2 in the tables below. Version 104.0
should be treated as version 4.03.
Get Position Commands
The following commands retrieve the position of the telescope in either RA/DEC or AZM-ALT coordinates.
The position is returned as a hexadecimal value that represents the fraction of a revolution around the axis. Two
examples are given below:
• If the Get RA/DEC command returns 34AB,12CE then the DEC value is 12CE in hexadecimal. As a percentage
of a revolution, this is 4814/65536 = 0.07346. To calculate degrees, simply multiply by 360, giving a value of
26.4441 degrees.
• If the precise GET AZM-ALT command returns 12AB0500,40000500 then the AZM value is 12AB0500 in
hexadecimal. As a percentage of a revolution, this is 313197824/4294967296 = 0.0729 or 26.252 degrees.
The standard commands offer a precision of 1/65536 * 360 * 60 * 60 = about 19.8 arcseconds per unit while the precise
commands offer a precision of 1/16777216 * 360 * 60 * 60 = about 0.08 arcseconds per unit (only the upper 24 bits are
used).
Note: if the telescope has not been aligned, the RA/DEC values will not be meaningful and the AZM-ALT values will
be relative to where the telescope was powered on. After alignment, RA/DEC values will reflect the actual sky,
azimuth will be indexed to North equals 0 and altitude will be indexed with 0 equal to the orientation where the optical
tube is perpendicular to the azimuth axis.
Command Function PC Command Hand Control
Response
Applies to
Versions
Get RA/DEC “E” “34AB,12CE#” 1.2+
Get precise RA/DEC “e” “34AB0500,12CE0500#” 1.6+
Get AZM-ALT “Z” “12AB,4000#” 1.2+
Get precise AZM-ALT “z” “12AB0500,40000500#” 2.2+
GOTO Commands
The following commands direct the telescope to GOTO a specified RA/DEC or AZM-ALT position. As with the Get
Position commands, the values are in hexadecimal and represent the fraction of a rotation around the axis.
Note: GOTO RA/DEC commands will not work unless the telescope is aligned.
Command Function PC Command Hand
Control
Response
Applies to
Versions
GOTO RA/DEC “R34AB,12CE” “#” 1.2+
GOTO precise RA/DEC “r34AB0500,12CE0500” “#” 1.6+
GOTO AZM-ALT “B12AB,4000” “#” 1.2+

GOTO precise AZM-ALT “b12AB0500,40000500” “#” 2.2+
Sync
To Sync to an object via serial commands, the user should center a known object in an eyepiece. Then the Sync serial
command should be sent, using the celestial coordinates (RA and DEC) for that object. This causes future GOTO or
Get Position commands to use coordinates relative to the Sync’d position, improving pointing accuracy to nearby
objects. (we probably don't need to mention "from the planetarium package" since it also improves pointing accuracy if
they GoTo objects via the hand control.) The format for the RA/DEC positions in the Sync command is identical to the
GOTO RA/Dec command.
Command Function PC Command Hand
Control
Response
Applies to
Versions
Sync RA/DEC “S34AB,12CE” “#” 4.10+
Sync precise RA/DEC “s34AB0500,12CE0500” “#” 4.10+
Tracking Commands
The following commands retrieve or set the tracking mode.
Depending on the mount type, following tracking modes are available:
0 = Off
1 = Alt/Az
2 = EQ North
3 = EQ South
Note: On the CGE and Advanced GT hand control versions 3.01 through 3.04 the value for EQ North is 1 and EQ
South is 2. This has been corrected to match the other models in current hand control versions.
Command Function PC Command Hand Control
Response
Applies to
Versions
Get Tracking Mode “t” chr(mode) & “#” 2.3+
Set Tracking Mode “T” & chr(mode) “#” 1.6+
Slewing Commands
The following commands allow you to slew (move) the telescope at fixed or variable rates.
For variable rates, multiply the desired rate by 4 and then separate it into a high and low byte. For example if the
desired tracking rate is 150 arcseconds/second, then:
trackRateHigh = (150 * 4) \ 256 = 2, and
trackRateLow = (150 * 4) mod 256 = 88
For fixed rates, simply use a value from 1-9 (or 0 to stop) to mimic the equivalent hand control rates.
Note: in most configurations, issuing the slew commands will override (or conflict with) the tracking mode of the
mount. Hence it is always best to disable tracking first using the Tracking Commands, issue the slew command, then
re-enable tracking. The main exception to this is when tracking equatorially - the fixed rate slews at 1 or 2 will not
override tracking. This can be useful to simulate autoguiding.
Note: on GT models, the fixed rate slews at rate 9 move at 3 degrees per second instead of the maximum rate.

Command Function PC Command Hand Control
Response
Applies to
Versions
Variable rate Azm (or
RA) slew in positive
direction
“P” &
chr(3) &
chr(16) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
“#” 1.6+
Variable rate Azm (or
RA) slew in negative
direction
“P” &
chr(3) &
chr(16) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
“#” 1.6+
Variable rate Alt (or
Dec) slew in positive
direction
“P” &
chr(3) &
chr(17) &
chr(6) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
“#” 1.6+
Variable rate Alt (or
Dec) slew in negative
direction
“P” &
chr(3) &
chr(17) &
chr(7) &
chr(trackRateHigh) &
chr(trackRateLow) &
chr(0) &
chr(0)
“#” 1.6+
Fixed rate Azm (or RA)
slew in positive
direction
“P” &
chr(2) &
chr(16) &
chr(36) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
“#” 1.6+
Fixed rate Azm (or RA)
slew in negative
direction
“P” &
chr(2) &
chr(16) &
chr(37) &
chr(rate) &
chr(0) &
chr(0) &
chr(0)
“#” 1.6+
Fixed rate Alt (or DEC) “P” & “#” 1.6+
Produktspecifikationer
Varumärke: | Celestron |
Kategori: | Teleskop |
Modell: | C6-NGT Computerized |
Behöver du hjälp?
Om du behöver hjälp med Celestron C6-NGT Computerized ställ en fråga nedan och andra användare kommer att svara dig
Teleskop Celestron Manualer

20 Oktober 2024

20 Oktober 2024

5 September 2024

2 September 2024

25 Augusti 2024

25 Augusti 2024

24 Augusti 2024

23 Augusti 2024

23 Augusti 2024

23 Augusti 2024
Teleskop Manualer
- Teleskop Carson
- Teleskop GlobalTronics
- Teleskop Marquant
- Teleskop Auriol
- Teleskop Bresser
- Teleskop Barska
- Teleskop Konig
- Teleskop Orion
- Teleskop Vivitar
- Teleskop Meade
- Teleskop Levenhuk
- Teleskop Vixen
- Teleskop Discovery
- Teleskop Danubia
- Teleskop SVBONY
- Teleskop DayStar Filters
- Teleskop Mizar
- Teleskop Sky-Watcher
- Teleskop National Geographic
- Teleskop IOptron
- Teleskop ZWO
- Teleskop Uniprodo
- Teleskop Zhumell
- Teleskop ExploreOne
Nyaste Teleskop Manualer

27 Mars 2025

4 Januari 2025

4 Januari 2025

1 Januari 2025

1 Januari 2025

27 December 2024

11 December 2024

27 Oktober 2024

16 Oktober 2024

16 Oktober 2024