Quick Reference Guide
English EN
Español ES
Français FR
Deutsch DE
Nederlands NL
1
EN
QUICK REFERENCE GUIDE
ÉPIX Flex Drive QRG Rev. 3
About This Guide
The ÉPIX Flex Drive Quick Reference Guide (QRG) has basic product information such as connection, mounting, menu
options, and control values. Download the User Manual from www.chauvetprofessional.com for more details.
Disclaimer
The information and specifications contained in this QRG are subject to change without notice.
LIMITED WARRANTY
FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE.
For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and
Germany: www.chauvetlighting.eu/warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the
period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This
warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this
warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows
the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This
warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to
country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands,
Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance.
DO NOT open this product. It contains no user-serviceable parts.
DISCONNECT from power before cleaning or replacing the fuse.
To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid
ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow
product to fully acclimate to the surrounding environment before connecting it to power.
CAUTION: This product’s housing may be hot when lights are operating.
Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
DO NOT leave any flammable material within 50 cm of this product while operating or connected to power.
USE a safety cable when mounting this product overhead.
DO NOT operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect
it. (IP20)
DO NOT operate this product if the housing, ports, or cables appear damaged.
DO NOT connect this product to a dimmer or rheostat.
Replace the fuse with one of the same type and rating.
ONLY connect this product to a grounded and protected circuit.
In the event of a serious operating problem, stop using immediately.
The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or
return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included
AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz.
AC Plug
ÉPIX Flex Drive Power Cord Quick Reference Guide
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the
product from power via breaker or by unplugging it.
EN
2
ÉPIX Flex Drive QRG Rev. 3
QUICK REFERENCE GUIDE
Fuse Replacement
1. Disconnect the product from power.
2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
3. Pry the safety cap out of the housing.
4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type
and rating.
5. Re-insert the fuse holder and reconnect power.
Signal Connections
The ÉPIX Flex Drive can link to a controller or controller software using an ethernet or 5-pin DMX connection. If using
other Art-Net™, sACN, or DMX-compatible products with the ÉPIX Flex Drive, they can all be controlled individually on a
single network. See the User Manual for information about how to connect and configure the product for these signals.
Control Personalities
The ÉPIX Flex Drive uses DMX, Art-Net™, and sACN for its control personalities:
Art-Net™ Connection
Art-Net™ is an Ethernet protocol that uses TCP/IP that transfers large amount of DMX512 data using an ethernet
connection over a large network. An Art-Net™ protocol document is available from www.chauvetprofessional.com.
Art-Net™ Designed by and Copyright Artistic Licence Holdings Ltd.
sACN Connection
Also known as ANSI E1.31, Streaming-ACN is an Ethernet protocol that uses the layering and formatting of Architecture
for Control Networks to transport DMX512 data over IP or any other ACN compatible network.
DMX Connection
The ÉPIX Flex Drive will work with a DMX controller using a 5-pin DMX data connection. A DMX Primer is available from
www.chauvetprofessional.com.
RDM (Remote Device Management)
Remote Device Management, or RDM, is a standard for allowing DMX-enabled devices to communicate bi-directionally
along existing DMX cabling. The ÉPIX Flex Drive supports RDM protocol that allows feedback to make changes to menu
map options. Download the User Manual from www.chauvetprofessional.com for more details.
The ÉPIX Flex Drive also supports RDM over Art-Net™.
Mounting
Before mounting this product, read the Safety Notes. Make sure the mounting clamp is capable of supporting the weight
of the product. For our CHAUVET Professional line of mounting clamps, go to http://trusst.com/products.
Mounting Diagram
Personality Channels Description
17 Channel 17 Dimmer, foreground and background RGB control, strobe, auto
programs, program speed, and offset, test mode
34 Channel 17 per output Enables output ports to be addressed separately for individual 17-
channel control
Pixel 720 per ÉPIX Flex 20 Complete pixel control. Only 170 LEDs are accessible by DMX. An
ethernet protocol (Art-Net™ or sACN) with multiple universes must be
used to access all connected LEDs.
Safety Cable
(such as CH-05 from
Chauvet)
Mounting Clamp
(such as CLP-15 from
Chauvet)
Ears for Rack
Mounting
M12 Threaded
Mounting Hole

Produktspecifikationer

Varumärke: Chauvet
Kategori: Inte kategoriserad
Modell: ÉPIX Flex Drive

Behöver du hjälp?

Om du behöver hjälp med Chauvet ÉPIX Flex Drive ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Chauvet Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer