Citizen CAL 775X Bruksanvisning

Citizen Titta CAL 775X

Läs nedan 📖 manual på svenska för Citizen CAL 775X (2 sidor) i kategorin Titta. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
CITIZEN QUARTZ
Analog Alarm
Model No. AQXXX
Cal. No. 775
Instruction Manual
CTZ-B6807
A. NAME OF PARTS
B. SETTING THE TIME AND
INITIAL SETTING FOR ALARM
Set the time and initial setting for the alarm by
following the procedure described below.
The alarm function will not operate correctly unless
the initial alarm setting procedure is performed.
1. Pull the crown out so that the second hand stops
at the “0” position (12:00).
2. Set the hour and minute hands to the current time
by turning the crown.
3. Set the alarm hour and minute hands to the
current time by pressing button Aor B.
Pressing and releasing button Bmoves the
hands counterclockwise in one minute steps.
3. Pressing and releasing button Amoves the
hands clockwise in one minute steps.
Press and hold button Aor Bto advance the
hands rapidly.
4. Push the crown back into the normal position.
C. USING THE ALARM
This alarm is set on the 12-hour system.
When the alarm set time is reached, the alarm will
sound for 10 seconds.
After the alarm sounds, the alarm hands will change
to indicate the current time.
Press button Aor B to stop alarm sound.
Setting the Alarm
(Perform this
procedure with the
crown in the normal
position.)
Press button Ato set
the alarm hour and
minute hands to the desired time.
Pressing and releasing button Amoves the hands
clockwise in one minute steps.
Press and hold button Ato advance the hands rapidly.
When the hour/minute hands and alarm hour/
minute hands are indicating different times:
Alarm is on
When the hour/minute hands and alarm hour/
minute hands are indicating the same time:
Alarm is off
<Alarm ON and OFF>
Once the alarm time has been set, it will remain in
the memory until alarm set time is changed. When
button B is pressed once when the alarm is off, the
alarm will be turned on and sound at the set time
stored in memory. Each time button B is pressed,
the alarm will switch between on and off. At this
time, the alarm will sound as indicated below
When alarm is switched to on: sounds twice
When alarm is switched to off: sounds once
D. LOW BATTERY WARNING FUNCTION
When the battery is low, the battery warning function
causes the second hand to move in 2 second
increments. Replace the battery as soon as possible.
*Even when this happens, the watch will still maintain
the correct time.
E. SPECIFICATIONS
1.Type: Analog quartz watch
2. Frequency: 32,768Hz
3. Accuracy: Within ±15 seconds per
month at normal
temperatures (5°C~35°C /
41°F~140°F)
4. Operating
temperature range: 10°C ~ +60°C
(14°F ~ 140°F)
5. Additional functions: Alarm function (12 hour
system)
Low battery warning
function
6. Battery No.: 280-72 (SR626W)
7. Battery life: Approx. 2 years
*These specifications are subject to change without
prior notice.
F. Precautions for long term use
1. Water-resistant
Check the chart to determine the
water resistant properties of this
watch.
• Always set the crown in the
normal position.
2. Avoid extreme temperatures
Avoid leaving your watch in extremely warn or cold
locations for long periods of time.
3. Avoid strong shocks
4. Avoid strong magnetic fields
5. Avoid chemicals and gasses
Avoid wearing this watch in the presence of
chemicals and gasses. If mercury or any chemical
(such as fuel, gasoline, thinner, alcohol. spray liquid
of cosmetics or the like), attaches, discolouration,
deterioration or damage to case, band or other
components may occur.
6. Avoid static electricity
The integrated circuits used in this watch are
sensitive to static electricity. If exposed to intense
static electricity, the watch’s display may loose
accuracy.
7. Keep the watch clean
It may become difficult to pull out the crown due to
dirt and dust getting caught between the crown and
case when the watch is worn for long periods of
time. To prevent this from happening, turn the crown
freely back and forth occasionally while it is in the
normal set position. Any dirt left on the case or band
may cause skin rash. A watchband will easily become
soiled with dust and perspiration because it is in
direct contact with the skin. Even a stainless or gold-
plated band may begin to corrode if it has not been
cleaned for a long period of time.
8. Periodic inspection
Getting your watch checked once every two or three
years is recommended to ensure long use and
trouble free operation.
9. Be sure to keep the battery away from infants or
small children: should accidental ingestion occur,
consult a doctor at once.
Indication Minor exposure to
water (washing
face, rain, etc.)
Watch face
NON
WATER RESIST
W.R ★★★/★★
BAR OR No
INDICATION
Case
(Case back)
WATER
RESIST(ANT)
WATER
RESIST(ANT)
Specifications
3 bar water
resistant watch
5 bar water
resistant watch
10/20 bar water
resistant watch
OK
OK
OK
NO
OK
OK
NO
NO
OK
NO
NO
NO
NO
NO
NO
Moderate
exposure to water
(washing, kitchen,
work swimming,
etc.)
Marine sports
(skin diving) Scuba diving
(with air tank)
Operation of the
crown with
moisture visible
Examples of use

Produktspecifikationer

Varumärke: Citizen
Kategori: Titta
Modell: CAL 775X

Behöver du hjälp?

Om du behöver hjälp med Citizen CAL 775X ställ en fråga nedan och andra användare kommer att svara dig




Titta Citizen Manualer

Titta Manualer

Nyaste Titta Manualer