KM28 THERMOMETER
1. GETTING STARTED
Attach the probe to the instrument. Note that the
connector is polarised with a “thin” pin and a “wide”
pin, care needs to be taken to insert the probe the
correct way.
To turn the instrument on/off press and release the
on/off button on the left of the case.
2. AUTO OFF FEATURE
If you do not turn the instrument off manually it will
switch off automatically after approximately 5/6
minutes.
3. SCALE SELECTION
Press the right hand button to change from °F to °C or
vice versa. The scale is displayed in the top right hand
of the window and is retained when switched off.
4. REPLACING THE BATTERY
Remove the battery cover by unscrewing the screw
on the rear of the unit. Do this away from the food
preparation area, taking care not to lose the screw.
The KM28 uses any standard 9 volt size battery and
these are readily available. Alkaline versions are
recommended for longest life.
Fit the battery and replace the cover. Take care not to
overtighten the screw or to leave too loose.
5. ACCESSORIES
PK19M Hypodermic needle probe
PK24M Penetration probe
CRS/5 Boot
6. SPECIFICATION
Sensor Type Thermocouple Type K
Measurement Range -40 to 1000°F /-40 to
500°C
Resolution 0.1° up to approx 195, 1°
above
Instrument Accuracy ±2°F / ±1°C
Ambient Temperature 32° to 122°F
Range 0° to 50°C
Battery 9V IEC 6LF22 standard/
alkaline
WARNINGS
TO AVOID DAMAGE OR BURNS, DO NOT MAKE TEMPERATURE
MEASUREMENTS IN MICROWAVE OR NORMAL OVENS.
DO NOT PLACE THE THERMOMETER IN A DISHWASHER AS IT IS NOT
DISHWASHER SAFE.
DO NOT PLACE THE THERMOMETER IN A FRIDGE OR FREEZER AS
DAMAGE MAY OCCUR DUE TO CONDENSATION FORMING WHEN THE
INSTRUMENT IS REMOVED.
REGULAR CLEANING OF THE THERMOMETER AND PROBES IS
RECOMMENDED USING A DAMP CLOTH AND NORMAL KITCHEN
CLEANER. DO NOT USE ANY FORM OF SOLVENT.
THIS IS A PRECISION INSTRUMENT AND SHOULD BE TREATED WITH
CARE IF LONG TERM PERFORMANCE IS TO BE ATTAINED.
© Comark Instruments Stock No. 16771 Issue 4
Comark Instruments
PO Box 500,
Beaverton, OR 97077, USA
Tel: (503) 643 5204
Email: sales@comarkusa.com
www.comarkusa.com
Comark Instruments
52 Hurricane Way,
Norwich, Norfolk, NR6 6JB, UK
Tel: +44 (0) 207 942 0712
Email: sales@comarkinstruments.com
www.comarkinstruments.com
Produktspecifikationer
Varumärke: | Comark |
Kategori: | Mattermometer |
Modell: | KM28 |
Behöver du hjälp?
Om du behöver hjälp med Comark KM28 ställ en fråga nedan och andra användare kommer att svara dig
Mattermometer Comark Manualer
9 September 2024
9 September 2024
9 September 2024
9 September 2024
8 September 2024
8 September 2024
8 September 2024
8 September 2024
8 September 2024
8 September 2024
Mattermometer Manualer
- Mattermometer Taylor
- Mattermometer Emerio
- Mattermometer Extech
- Mattermometer Hendi
- Mattermometer Patton
- Mattermometer Velleman
- Mattermometer La Crosse Technology
- Mattermometer Weber
- Mattermometer AcuRite
- Mattermometer Nutrichef
- Mattermometer Technoline
- Mattermometer Inkbird
- Mattermometer Switel
- Mattermometer TFA
- Mattermometer Reer
- Mattermometer Char-Broil
- Mattermometer Napoleon
- Mattermometer Tepro
- Mattermometer Fluke
- Mattermometer Xavax
- Mattermometer HQ
- Mattermometer Outdoorchef
- Mattermometer Laserliner
- Mattermometer Testo
- Mattermometer Rösle
- Mattermometer Maverick
- Mattermometer TFA Dostmann
- Mattermometer Emga
- Mattermometer Ooni
- Mattermometer Grill Eye
- Mattermometer GrillEye
- Mattermometer PCE Instruments
- Mattermometer FCC BBQ
- Mattermometer MEATER
- Mattermometer Tescoma
- Mattermometer Mastrad
- Mattermometer ETI
Nyaste Mattermometer Manualer
4 Januari 2025
29 December 2024
27 December 2024
9 December 2024
8 December 2024
8 December 2024
21 Oktober 2024
21 Oktober 2024
6 Oktober 2024
26 September 2024