Daikin 3MXM68N2V1B9 Bruksanvisning

Daikin Luftkonditionering 3MXM68N2V1B9

Läs nedan 📖 manual på svenska för Daikin 3MXM68N2V1B9 (84 sidor) i kategorin Luftkonditionering. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/84
Installer reference guide
R32 Split series
2MXM68N2V1B
3MXM40N2V1B9
3MXM40N2V1B8
3MXM40N2V1B7
3MXM52N2V1B9
3MXM52N2V1B8
3MXM52N2V1B7
3MXM68N2V1B9
3AMXM52N2V1B9
3AMXF52A2V1B9
3MXF52A2V1B9
3MXF68A2V1B9
4MXM68N2V1B9
4MXM80N2V1B9
5MXM90N2V1B9
Table of contents
Installer reference guide
2
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1D – 2021.03
Table of contents
1 About the documentation 4
1.1 About this document ...................................................................................................................................................... 4
2 General safety precautions 5
2.1 About the documentation .............................................................................................................................................. 5
2.1.1 Meaning of warnings and symbols ................................................................................................................ 5
2.2 For the installer............................................................................................................................................................... 6
2.2.1 General ........................................................................................................................................................... 6
2.2.2 Installation site ............................................................................................................................................... 7
2.2.3 Refrigerant — in case of R410A or R32.......................................................................................................... 10
2.2.4 Electrical ......................................................................................................................................................... 12
3 Specific installer safety instructions 15
4 About the box 20
4.1 Overview: About the box................................................................................................................................................ 20
4.2 Outdoor unit ................................................................................................................................................................... 20
4.2.1 To unpack the outdoor unit ........................................................................................................................... 20
4.2.2 To remove the accessories from the outdoor unit........................................................................................ 21
5 About the unit 23
5.1 Overview: About the unit ............................................................................................................................................... 23
5.2 Identification ................................................................................................................................................................... 23
5.2.1 Identification label: Outdoor unit .................................................................................................................. 23
6 Unit installation 24
6.1 Preparing the installation site......................................................................................................................................... 24
6.1.1 Installation site requirements of the outdoor unit........................................................................................ 25
6.1.2 Additional installation site requirements of the outdoor unit in cold climates............................................ 27
6.2 Opening the unit ............................................................................................................................................................. 28
6.2.1 About opening the unit .................................................................................................................................. 28
6.2.2 To open the outdoor unit............................................................................................................................... 28
6.3 Mounting the outdoor unit............................................................................................................................................. 28
6.3.1 About mounting the outdoor unit ................................................................................................................. 28
6.3.2 Precautions when mounting the outdoor unit.............................................................................................. 29
6.3.3 To provide the installation structure ............................................................................................................. 29
6.3.4 To install the outdoor unit ............................................................................................................................. 30
6.3.5 To provide drainage........................................................................................................................................ 30
6.3.6 To prevent the outdoor unit from falling over .............................................................................................. 31
7 Piping installation 32
7.1 Preparing refrigerant piping ........................................................................................................................................... 32
7.1.1 Refrigerant piping requirements.................................................................................................................... 32
7.1.2 Refrigerant piping insulation.......................................................................................................................... 33
7.1.3 Refrigerant piping length and height difference ........................................................................................... 34
7.2 Connecting the refrigerant piping .................................................................................................................................. 35
7.2.1 About connecting the refrigerant piping ....................................................................................................... 35
7.2.2 Precautions when connecting the refrigerant piping.................................................................................... 35
7.2.3 Guidelines when connecting the refrigerant piping...................................................................................... 36
7.2.4 Pipe bending guidelines ................................................................................................................................. 37
7.2.5 To flare the pipe end ...................................................................................................................................... 37
7.2.6 Connections between outdoor and indoor unit using reducers................................................................... 38
7.2.7 Using the stop valve and service port............................................................................................................ 40
7.2.8 To connect the refrigerant piping to the outdoor unit ................................................................................. 42
7.3 Checking the refrigerant piping...................................................................................................................................... 42
7.3.1 About checking the refrigerant piping........................................................................................................... 42
7.3.2 Precautions when checking the refrigerant piping........................................................................................ 43
7.3.3 To check for leaks........................................................................................................................................... 43
7.3.4 To perform vacuum drying............................................................................................................................. 44
8 Charging refrigerant 46
8.1 About charging refrigerant ............................................................................................................................................. 46
8.2 About the refrigerant...................................................................................................................................................... 47
8.3 Precautions when charging refrigerant.......................................................................................................................... 48
8.4 To determine the additional refrigerant amount .......................................................................................................... 48
8.5 To determine the complete recharge amount .............................................................................................................. 48
8.6 To charge additional refrigerant..................................................................................................................................... 49
Table of contents
Installer reference guide
3
2MXM68+3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
4P600463-1D – 2021.03
8.7 To fix the fluorinated greenhouse gases label ............................................................................................................... 49
9 Electrical installation 50
9.1 About connecting the electrical wiring .......................................................................................................................... 50
9.1.1 Precautions when connecting the electrical wiring....................................................................................... 50
9.1.2 Guidelines when connecting the electrical wiring......................................................................................... 52
9.1.3 Specifications of standard wiring components.............................................................................................. 53
9.2 To connect the electrical wiring to the outdoor unit..................................................................................................... 54
10 Finishing the outdoor unit installation 56
10.1 To finish the outdoor unit installation............................................................................................................................ 56
10.2 To close the outdoor unit ............................................................................................................................................... 56
11 Configuration 57
11.1 About standby electricity saving function...................................................................................................................... 57
11.1.1 To turn on standby electricity saving function .............................................................................................. 57
11.2 About priority room function ......................................................................................................................................... 58
11.2.1 To set the priority room function................................................................................................................... 58
11.3 About night quiet mode.................................................................................................................................................. 58
11.3.1 To turn on the night quiet mode.................................................................................................................... 58
11.4 About heat mode lock .................................................................................................................................................... 59
11.4.1 To turn on heat mode lock ............................................................................................................................. 59
11.5 About cool mode lock..................................................................................................................................................... 59
11.5.1 To turn on cool mode lock ............................................................................................................................. 59
12 Commissioning 61
12.1 Overview: Commissioning .............................................................................................................................................. 61
12.2 Precautions when commissioning.................................................................................................................................. 61
12.3 Checklist before commissioning ..................................................................................................................................... 62
12.4 Checklist during commissioning ..................................................................................................................................... 62
12.5 Trial operation and testing ............................................................................................................................................. 62
12.5.1 About wiring error check................................................................................................................................ 63
12.5.2 To perform a test run ..................................................................................................................................... 64
12.6 Starting up the outdoor unit........................................................................................................................................... 64
13 Hand-over to the user 65
14 Maintenance and service 66
14.1 Overview: Maintenance and service .............................................................................................................................. 66
14.2 Maintenance safety precautions.................................................................................................................................... 66
14.3 Checklist for yearly maintenance of the outdoor unit................................................................................................... 66
14.4 About the compressor .................................................................................................................................................... 67
15 Troubleshooting 68
15.1 Overview: Troubleshooting ............................................................................................................................................ 68
15.2 Precautions when troubleshooting ................................................................................................................................ 68
15.3 Solving problems based on symptoms ........................................................................................................................... 68
15.3.1 Symptom: Indoor units fall, vibrate or make noise ....................................................................................... 68
15.3.2 Symptom: The unit is NOT heating or cooling as expected........................................................................... 69
15.3.3 Symptom: Water leakage ............................................................................................................................... 69
15.3.4 Symptom: Electrical leakage .......................................................................................................................... 69
15.3.5 Symptom: Priority room setting does NOT function..................................................................................... 69
15.3.6 Symptom: Unit does NOT function or burn damage..................................................................................... 69
15.4 Solving problems based on LED behaviour .................................................................................................................... 70
15.4.1 Fault diagnosis using LED on outdoor unit PCB ............................................................................................. 70
16 Disposal 72
16.1 Overview: Disposal.......................................................................................................................................................... 72
16.2 To pump down ................................................................................................................................................................ 72
16.3 To start and stop forced cooling..................................................................................................................................... 73
17 Technical data 75
17.1 Wiring diagram................................................................................................................................................................ 75
17.1.1 Unified wiring diagram legend ....................................................................................................................... 75
17.2 Piping diagram: Outdoor unit......................................................................................................................................... 77
18 Glossary 82

Produktspecifikationer

Varumärke: Daikin
Kategori: Luftkonditionering
Modell: 3MXM68N2V1B9
Färg på produkten: Blauw
Vikt: 306 g
Bredd: 155 mm
Djup: 86 mm
Höjd: 26 mm
Husmaterial: Metaal
LED-indikatorer: Ja
Nuvarande: 1 A
På / Av knapp: Ja
Inkluderar AC-adapter: Ja
Strömförbrukning (max): 1.8 W
DC-spänningsingång: 5 V
Certifiering: FCC, CE
Plug and play: Ja
Nätverksstandard: IEEE 802.3, IEEE 802.3az, IEEE 802.3u, IEEE 802.3x
Förvaringstemperatur: -10 - 70 °C
Nätverksprotokoll som stöds: CSMA / CD
Förvaringsfuktighet: 5 - 95 procent
Rackmontering: Nee
Upphängningssystem för väggen: Ja
Auto MDI/MDI-X: Ja
Power over Ethernet (PoE): Nee
Växlingskapacitet: 1 Gbit/s
MAC-ställbar: 2000 entries
10G-stöd: Nee
Dataflödeshantering: Ja
Antal grundläggande switchande RJ-45 Ethernet-portar: 5
Nätkontakt: DC-in ingang
Typ grundläggande switchande RJ-45 Ethernet-portar: Fast Ethernet (10/100)
Genomströmning: 0.744 Mpps
Full duplex: Ja
Koppar Ethernet-kabelteknik: 10BASE-T, 100BASE-TX
Värmeavledning: 6.1 BTU/h
Automatisk förhandling: Ja
Drifttemperatur (TT): 0 - 50 °C
Relativ luftfuktighet i drift (VV): 5 - 95 procent
Harmoniserad systemkod (HS): 85176990
Lagra och vidarebefordra: Ja
MAC-adress självåldrande funktion: Ja
MAC-adress självlärande funktion: Ja
Halv duplex: Ja

Behöver du hjälp?

Om du behöver hjälp med Daikin 3MXM68N2V1B9 ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Daikin Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer