Dometic DFSD 16121 Bruksanvisning

Läs nedan 📖 manual på svenska för Dometic DFSD 16121 (28 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 10 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/28
INSTALLATION
MANUAL
DF Series Furnace
Models DFSAD12, DFSD12, DFSD16, DFSD20, DFMD16,
DFMD20, DFMD25, DFMD30, DFMD35, DFLD35,
DFLD40, DFLA35, DFLA40
USA & CANADA
SERVICE OFFICE
Dometic Corporation
5155 Verdant Drive
Elkhart, IN 46516
SERVICE CENTER &
DEALER LOCATIONS
Visit:
dometic.com/support
Rev A Form No. 33400 01/21
©2021 Dometic Corporation
LaGrange, IN 46761
INTRODUCTION 2
.............................................................................
IMPORTANT SAFETY INSTRUCTIONS AND DOCUMENT SYMBOLS 2
....................................
GENERAL INFORMATION 4
......................................................................
PRE-INSTALLATION 6
...........................................................................
INSTALLATION 16
..............................................................................
TESTING
...................................................................................
24
TROUBLESHOOTING 25
........................................................................
REPLACEMENT PARTS 25
........................................................................
Read these instructions carefully. These instructions MUST stay with this product.
WARNING: FIRE OR EXPLOSION HAZARD.
Failure to follow safety warnings exactly could result in serious injury, death, or
property damage.
WARNING:
If the information in these instructions is not followed exactly, a fire or
explosion may result causing property damage, personal injury, or loss of life.
Do not store or use gasoline or other flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service
agency, or the gas supplier.
WARNING
Cancer and Reproductive Harm
www.P65Warnings.ca.gov
2
INTRODUCTION
This manual is for use by an authorized service technician to install a Dometic DF Series Furnace. Should you require further
information, contact Dometic. The design of the DF Series Furnace (hereinaer referred to as “Furnace”) has been certified for
installation in a recreational vehicle (hereinaer referred to as “RV”) as an MSP Category III Furnace. Follow these instructions to
ensure the correct installation of the Furnace. Failure to install the Furnace according to these installation instructions nullifies the
Furnace warranty.
Dometic Corporation reserves the right to modify appearances and specifications without notice.
IMPORTANT SAFETY INSTRUCTIONS AND DOCUMENT SYMBOLS
This manual has safety information and instructions to help you eliminate or reduce the risk of accidents and injuries.
A. Recognize Safety Information
This is the safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow
this symbol to avoid possible injury or death.
B. Understand Signal Words
A signal word will identify safety messages and property damage messages, and will indicate the degree or level of hazard
seriousness.
indicates a hazardous situation that, if avoided, could result in death or serious injury.NOT
indicates a hazardous situation that, if avoided, could result in minor or moderate injury.NOT
is used to address practices related to physical injury.NOT
Indicates additional information that is not related to physical injury.
C. Supplemental Directives
Read and follow all safety information and instructions to avoid possible injury or death.
Read and understand these instructions before installation of this product.
Incorrect installation of this product can lead to serious injury or death.
The installation comply with all applicable local or national codes, including the latest edition of the following standards:MUST
U.S.A.
ANSI/NFPA70, National Electrical Code (NEC)
ANSI/RVIA LV, Low Voltage Systems in Conversion and
Recreational Vehicles
ANSI/NFPA 1192, Recreational Vehicles Code
ANSI Z223.1, NFPA 54 National Fuel Gas Code
ANSI 1195, Park Trailers
ANSI Z21.47-2016
ANSI Z21.86-2016
CANADA
CSA C22.1, Parts l & ll, Canadian Electrical Code
CSA Z240 RV Series, Recreational Vehicles
CAN/CGA B149, Natural Gas and Propane Installation
Code
CSA 2.3-2016
CSA 2.32-2016
FOR DFLA35 and DFLA40 Models Only
This Furnace is manufactured for use with Liquid Propane (LP) gas. A kit has been provided with the Furnace, so that a qualified
service technician can convert the Furnace for use with natural gas. Any conversion to natural gas must conform with local
codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 Natural Gas and Propane
Installation Code, in addition to the Standard for Recreational Vehicles NFPA1192 and CSA Z240 RV Recreational Vehicle Code.
3
IMPORTANT SAFETY INSTRUCTIONS AND DOCUMENT SYMBOLS
D. General Safety Messages
FIRE OR EXPLOSION HAZ ARD. Failure to obey the following warnings could result in property damage, serious
injury, or death:
Make sure that all intended components are attached to the Furnace aer installation. The Furnace should be used NEVER
without all intended components attached.
Do store gasoline, oil- or gasoline-soaked rags, or other flammable vapors and liq uids, inside storage compartment(s). NOT
refueling or parking near a gas oline pump, make sure LP gas appliances (vented to the outside of the RV) are BEFORE ALL
shut OFF. Oth erwise, fumes from gasoline pumps could come into contact with an LP gas appliance burner flame and ignite.
Turn OFF LP gas supply at tank.
Use only with the type of gas approved for the Furnace. Refer to the Furnace rating plate.
Use only Dometic replacement parts and components, which are specifically approved for use with the Furnace.
CARBON MONOXIDE HAZ ARD. Failure to obey the following warnings could result in property damage, serious
injury, or death:
This Furnace can produce carbon monoxide, which has no odor and can be life-threatening. The burner and vent assembly
system be kept clean.MUST
Doors be properly sealed and the dra cap and assemblies MUST MUST be adjusted and sealed correctly to prevent
carbon monoxide from entering the RV.
Do allow snow or any objects to block the exhaust system of the Furnace.NOT
Combustion products be properly vented to the atmosphere and all combustion air supplied to the burner MUST MUST be
drawn from the outside atmosphere.
Use only Dometic replacement parts and components, which are specifically approved for use with the Furnace.
ELECTRICAL SHOCK HAZ ARD. Failure to obey the following warnings could result in property damage, serious
injury, or death:
Make sure the AC power is dis connected from the Furnace during installation.
Furnaces with 12 VDC connection are for low-voltage battery or direct current only. DC Furnaces are designed for negative
ground 12 VDC only. Do attempt to alter the Furnace for a positive ground system or connect the Furnace directly to NOT
120 or 240 VAC.
Do use a battery charger to supply power to DC model Furnaces, even when testing.NOT
Use only Dometic replacement parts and components, which are specifically approved for use with the Furnace.
CRITICAL INSTALLATION WARNINGS. Failure to obey the following warnings could result in property damage,
serious injury, or death:
This Furnace be installed by a qualified service technician.MUST
Do modify this Furnace in any way. Modifi cation can be extremely hazardous.NOT
Do install this Furnace if any part has been underwater.NOT
Sheet metal edges are sharp; take care when handling or touching edges.
Protect Furnace electrical components from water.
Protect building materials from degrading from vent assembly gas exhaust.
Compartment be closed when operating the Furnace.MUST
Do install screens over the intake air or exhaust vents for any reason.NOT

Produktspecifikationer

Varumärke: Dometic
Kategori: Inte kategoriserad
Modell: DFSD 16121

Behöver du hjälp?

Om du behöver hjälp med Dometic DFSD 16121 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Dometic Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer