Electrolux EWF02 Bruksanvisning

Läs nedan 📖 manual på svenska för Electrolux EWF02 (1 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/1
10200 David Taylor Drive, Charlotte, NC 28262, 2018 ELECTROLUX HOME PRODUCTS, INC. 1-877-4ELECTROLUX (1-877-435-3287)
PN A02686306
NSF is a trademark of NSF International.
APPLICATION GUIDELINES ONDITIONS OF USE / C
Water Supply Potable Water
Water Temp. Max. 100°F (38°C), Min. 33°F (0.6°C)
Water Pressure 30 - 100 psi (206.8 - 689.5 kPa)
Service Flow 0.65 gpm maximum (2.46 lpm)
It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements
be carried out for the product to perform as advertised. See Use & Care Manual for Warranty information.
While testing was performed under standard laboratory conditions, actual performance may vary.
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standard 42,
Standard 53 and Standard 401.
The compounds certified under NSF 401 have been deemed as emerging compounds/incidental contami-
nants. Emerging compounds/incidental contaminants are those compounds that have been detected in
drinking water supplies at trace levels. While occurring at only trace levels, these compounds can affect the
public acceptance/perception of drinking water quality.
PERFORMANCE DATA SHEET
Model: PureAdvantage® Ultra Using Replacement Cartridge EWF02™
WARNING
Read entire manual. Failure to follow all guides and rules could cause personal injury or property damage.
Check with your local public works department for plumbing codes. You must follow their guidelines as you
install the Water Filtration system.
Your Water Filtration system will withstand up to 100 lbs/in2 (psi) water pressure.
To reduce the risk associated with choking:
DO NOT allow children under 3 years of age to have access to small parts during the installation of this product.
To reduce the risk associated with the ingestion of contaminants:
DO NOT use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after use of the system. Systems certified for cyst reduction may be used on disinfected water that
may contain filterable cysts.
REPLACEMENT CARTRIDGE INFORMATION
Replacement Element: EWF02™. For estimated cost of replacement
elements please call 1-877-4ELECTROLUX (1-877-435-3287) or visit us on the
web at ElectroluxAppliances.com
PERFORMANCE DATA
MODEL: PureAdvantage® Ultra. Use the replacement cartridge EWF02™.
System tested and certified by NSF International against NSF/
ANSI Standard 42, Standard 53, and Standard 401 for the
reduction of substances listed below.
SYSTEM SPECIFICATIONS
Capacity 125 gallons (473 liters)
Substance
Reduction
Average
Influent
NSF/ANSI Specified
Challenge
Concentration
Average %
Reduction/
Minimum
Reduction
Average Product
Water
Concentration
Maximum Permissible
Concentration
NSF Reduction
Requirements
NSF Test
Report
Chlorine 2.0 mg/L 2.0 mg/L ± 10% >97.4 / 97.4% 0.05 mg/L J-00297278N/A ≥ 50%
Nominal Particulate
Class I
4,600,000
pts/mL
At least 10,000 particles/mL 99.3 / 99.0% 38,000 pts/ml ≥85% J-00297279 N/A
Asbestos 290 MFL 10 to 100 MFL; fibers greater than 10
µm in length
>99 / >99% < 1MLF N/A
≥99% J-00297237
Atrazine 8.8 ug/L 9 ug/L ± 10% >94.3 / 94.3% 0.5 ug/L 3 ug/L J-00297270N/A
Benzene 14 ug/L 15 ug/L ± 10% 0.5 ug/L 5 ug/L J-00297271
>96.5 / 96.5% N/A
Carbofuran 80 ug/L 80 ug/L ± 10% >98.8 / 98.8% 1 ug/L 40 ug/L J-00297273N/A
Cysts* 140,000
cycst/L
Minimum 50,000 cysts/L >99.99 / 99.99% <1 cyst/L N/A ≥99.95% J-00297235
Endrin 5.7 ug/L 6 ug/L ± 10% 0.2 ug/L 2 ug/L J-00297646
96.4 / 94.8% N/A
Lead pH 6.5 150 ug/l 150 ug/L ± 10% 99.6 / 99.3% 0.5 ug/L 10 ug/L J-00297265 N/A
Lead pH 8.5 150 ug/l 150 ug/L ± 10% >99.7 / >99.7% 0.5 ug/L 10 ug/L J-00297266N/A
Lindane 2.0 ug/L 2 ug/L ± 10% >99.0 / 98.9% 0.02 ug/L 0.2 ug/L J-00297274N/A
Mercury pH 6.5 5.5 ug/L 6 ug/L ± 10% 0.2 ug/L 2 ug/L J-0029726896.3 / 96.3% N/A
Mercury pH 8.5 5.7 ug/L 6 ug/L ± 10% 94.5 / 89.5% 0.3 ug/L 2 ug/L J-00297267N/A
O-Dichlorobenzene 1800 ug/L 1800 ug/L ±10% >99.9 / 99.9% 0.5 ug/L 600 ug/L J-00297647N/A
P-Dichlorobenzene 200 ug/l 225 ug/L ± 10% >99.7 / 99.8% 0.5 ug/L 75 ug/L J-00297651N/A
Tetrachloroethylene 14 ug/L 15 ug/L ± 10% >96.4 / 95.8% 0.5 ug/L 5 ug/L J-00297648N/A
Toxaphene (Pesticide) 15 ug/L 15 ug/L ± 10% 1 ug/L 3 ug/L J-00297649
>93.2 / 93.1% N/A
2,4-D (Herbicide) 220 ug/L 210 ug/L ± 10% 1.6 ug/L 70 ug/L J-0029764599.3 / 97.4% N/A
Atenolol 220 ug/L 200 ng/L ± 20% >95.5 / 95.5% 10 ng/L 30 ng/L J-00297275N/A
Bisphenol A >99.1 / 99.1%2200 ng/L 2000 ng/L ± 20% 20 ng/L 300 ng/L J-00297276 N/A
Estrone 140 ng/L 140 ng/L ± 20% 5 ng/L 20 ng/L J-00297276
>96.6 / 96.4% N/A
Ibuprofen (Pharma) 440 ng/L 400 ng/L ± 20% >95.5 / 95.3% 20 ng/L 60 ng/L J-00297276 N/A
Naproxen 160 ng/L 140 ng/L ± 20% 5 ng/L 20 ng/L J-00297276
>96.8 / 96.7% N/A
Nonylphenol 1500 ng/L 1400 ng/L ± 20% 50 ng/L 200 ng/L J-00297276>96.7 / 96.6% N/A
Phenytoin 220 ng/L 200 ng/L ± 20% >95.5 / 95.5%
10 ng/L 30 ng/L J-00297276N/A
Trimethoprim 140 ng/L 140 ng/L ± 20% 5 ng/L 20 ng/L J-00297275>96.6 / 96.5% N/A
VOC 300 ug/L 300 ug/L ± 10% 99.8/99.2% 2.3 ug/L 15 ng/L J-00297650≥95%
* Based on the use of Cryptosporidium parvum oocystsContaminant reduction determined by NSF testing.
CAUTION
To reduce the risk associated with property damage due to water leakage
or flooding:
Read and follow the Use & Care Manual before installation and use of
this system.
Change the disposable filter cartridge at the recommended interval; You
MUST replace the disposable filter cartridge every 6 months or sooner.
Failure to replace the disposable filter cartridge at recommended
intervals may lead to reduced filter performance and failure of the filter,
causing property damage from water leakage or flooding.
Installation and use MUST comply with all state and local plumbing codes.
Protect from freezing, remove filter cartridge when temperatures are
expected to drop below 3F (4.4°C).
DO NOT install systems in areas where ambient temperatures may go
above 110°F (43.3°C).
DO NOT install on hot water supply lines. The maximum operating water
temperature of this filter system is 100°F (37.8°C).

Produktspecifikationer

Varumärke: Electrolux
Kategori: Inte kategoriserad
Modell: EWF02
Enhetsplacering: Vrijstaand
Färg på produkten: Wit
Dörrgångjärn: Rechts
Bredd: 600 mm
Djup: 630 mm
Höjd: 1850 mm
Nettoskatt: 100 W
Sladdlängd: 2.7 m
Frys nettokapacitet: 78 l
Fryskapacitet: 4 kg/24u
Kylskåpets nettokapacitet: 245 l
antal stjärnor: 4*
Inbyggd frys: Nee
Kylmedium: R600a

Behöver du hjälp?

Om du behöver hjälp med Electrolux EWF02 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Electrolux Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer