Elica Trento ETR634SS Bruksanvisning

Elica Fläktkåpa Trento ETR634SS

Läs nedan 📖 manual på svenska för Elica Trento ETR634SS (44 sidor) i kategorin Fläktkåpa. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/44
Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
Guía de
instalación, uso y
mantenimiento
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0180582
Printed in Mexico
Models: KIT0179549
2
English
APPROVED FOR RESIDENTIAL APPLIANCES
FOR RESIDENTIAL USE ONLY
READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn o power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V~ AC, 60 Hz. 15 or 20 A Branch Circuit.
Important Safety Notice 3
Electrical Requirements 4
Tools and parts 5
Product dimensions 6
Venting Requirements 6
Installation Instructions 7
Prepare location 7
Install In-Blower system 12
Make Electrical Connection for In-Line Blower Motor System 13
Make Electrical Connection Inside Range Hood Between In-Line Blower System and Range Hood 14
3
Important Safety Notice
I CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR
VAPOURS.
I WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning the unit, switch power o at
service panel and lock service panel disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag,
to the service panel.
C. Installation work and electrical wiring must be done by
qualified person(s) in accordance with all applicable codes
& standards, including fire-rated construction.
D. Sucient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting.
Follow the heating equipment manufacturers guideline and
safety standards such as those published by the national
fire protection association (NFPA), the american society
for heating, refrigeration and air conditioning engineers
(ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.
I CAUTION
To reduce risk of fire and to properly exhaust air, be sure to
duct air outside - do not vent exhaust air into spaces within
walls, ceilings, attics, crawl spaces, or garages.
I WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT
WORK.
Install this hood in accordance with all requirements specified.
I WARNING
To reduce the risk of fire or electric shock, do not use this
hood with any external solid state speed control device.
I WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (I.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for
the size of the surface element.
I WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:a
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
other metal tray, then turn o the gas burner or the electric
element. BE CAREFUL TO PREVENT BURNS. If the flames
do not go out immediately, EVACUATE AND CALL THE
FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and you
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
e) Ducted fans must always be vented to the outdoor.
aBased on “Kitchen Fire Safety Tips” published by NFPA.
CAUTIONI
Automatically Operated Device - To reduce the risk of
Injury disconnect from power supply before servicing.
For double Blower Motor Models (ELN136S2, ELN142S2, ELN148SS, ELI136S2, ELI142S2, EAR134S4, EAR140S4, EAR146S4,
ECL136S4, ECL142S4, ECL148S4, ETR134S1, ETR146SS)

Produktspecifikationer

Varumärke: Elica
Kategori: Fläktkåpa
Modell: Trento ETR634SS
Enhetsplacering: Volledig ingebouwd
Typ av operation: Knoppen
Inbyggd display: Ja
Vikt: 44000 g
Bredd: 598 mm
Djup: 570 mm
Höjd: 805 mm
Nettoskatt: 2100 W
Antal platsinställningar: 14 couverts
Dörrfärg: Niet van toepassing
Sladdlängd: 1.7 m
Fördröjd starttimer: Ja
Startfördröjning: 24 uur
Indikering av återstående tid: Ja
Torkningsklass: A
Cykelns längd: 226 min
Ljudnivå: 44 dB
Årlig-energiförbrukning: 213 kWu
Energieffektivitetsklass (gammal): A+++
Installationsfackets bredd: 600 mm
Installationsfack djup: 570 mm
Vattenförbrukning per cykel: 9.7 l
Nuvarande: 10 A
Installationsfack höjd (min): 805 mm
Integrerad timer: Ja
Djup när dörren är öppen: 116.5 mm
Produktstorlek: Volledige grootte (60 cm)
Typ av bästa fack: Lade
Varningssignal: Ja
LED-bakgrundsbelysning: Ja
Översvämningsskydd: Ja
Glasskydd: Ja
Halvlastad: Ja
Tvättprogram: Auto, Glass/delicate, Eco, Intensive, Quick
Energiförbrukning per cykel: 0.75 kWu
Årlig vattenförbrukning: 2716 l
Avloppsslangens längd: 1.5 m
Vattentillförselslangens längd: 1.5 m
Val av sensorprogram: Ja
Installationsfack höjd (max): 870 mm
Temperatur (max): 75 °C
Vattentillgång: Cold, Hot
Strömförbrukning (när avstängd): 0.2 W
Bakgrundsbelysning-färg: Wit
AC-ingångsspänning: 230 V
AC-ingångsfrekvens: 50 Hz

Behöver du hjälp?

Om du behöver hjälp med Elica Trento ETR634SS ställ en fråga nedan och andra användare kommer att svara dig




Fläktkåpa Elica Manualer

Fläktkåpa Manualer

Nyaste Fläktkåpa Manualer