SFAH
Flow sensor
Operating instruc-
tion
8185054
8185054
2023-08c
[8185056]
Translation of the original instructions
IO-Link is a registered trademark of its respective trademark holder in certain countries.
Festo — SFAH — 2023-08c
3
Table of contents
1 Applicable documents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Safety instructions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Intended use. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.3 Training of qualified personnel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 UL/CSA certification. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 Additional information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4 Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Structure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1.1 Product design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1.2 Display components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4.2 Function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2.1 Functional principle. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2.2 Operating statuses. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4.2.3 Switching outputs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
4.2.4 Standard switching condition for volume values - ‘REF’/‘Cond’. . . . . . . . . . . . 13
4.2.5 Filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.2.6 Analogue output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4.2.7 Minimum value and maximum value. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2.8 Replicate parameter function. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2.9 Offset adjustment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5 Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.1 Mounting the sensor on the H-rail. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
5.2 Mounting the sensor with wall mounting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.3 Mounting sensor on plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
5.4 Mounting sensor on plate at the side. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
5.5 Mounting sensor with front panel mounting kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.1 Pneumatic installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.1.1 Infeed situation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
6.2 Electrical installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
7 Commissioning. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.1 Switching on the sensor in RUN mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.2 Displaying parameters in SHOW mode. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
7.3 Configuring the sensor in EDIT mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.3.1 Entering security code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
7.3.2 Configuring the switching output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
7.3.3 Changing device settings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.3.4 Setting the volume pulse output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
7.3.5 Setting the analogue output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Festo — SFAH — 2023-08c
Safety
5
1 Applicable documents
All available documents for the product
èwww.festo.com/sp.
Document Content
IO-Link IODD Device description file
Tab. 1: Applicable documents
2 Safety
2.1 Safety instructions
Only use the product in its original condition without unauthorised modifications.
Only use the product if it is in perfect technical condition.
Observe labelling on the product.
Only use media in accordance with the specifications Technical data.è
The product may generate high frequency interference, which may require interference suppression
measures in residential areas.
2.2 Intended use
The flow sensor monitors the flow rate of gaseous media in pipe systems or terminals in industrial
applications.
2.3 Training of qualified personnel
Work on the product may only be carried out by qualified personnel who can evaluate the work and
detect dangers. The qualified personnel have skills and experience in dealing with electropneumatic
(open-loop) control technology.
2.4 UL/CSA certification
In combination with the UL inspection mark on the product, the information in this section must also
be observed in order to comply with the certification conditions of Underwriters Laboratories Inc. (UL)
for USA and Canada.
UL/CSA certification information
Product category code QUYX, QUYX7
File number E322346
Considered standards UL 61010-1
CAN/CSA C22.2 No. 61010-1
UL mark
Tab. 2: UL/CSA certification information
6
Festo — SFAH — 2023-08c
Product overview
The Front panel mounting kit SAMH-FH-F can be used only for mounting SFAH behind a plate. Cabinet
mounting was not evaluated by UL.
WARNING
The unit shall be supplied by a power source which fulfils the requirements on a limited-energy
circuit in accordance to IEC/EN/UL/CSA 61010-1 or on a Limited Power Source (LPS) in accordance to
IEC/EN/UL/CSA 60950-1 or IEC/EN/UL/CSA 62368-1 or a Class 2 circuit in accordance to NEC or CEC.
3 Additional information
Contact the regional Festo contact if you have technical problems
èwww.festo.com.
Accessories and spare parts èwww.festo.com/catalogue.
4 Product overview
4.1 Structure
4.1.1 Product design
4
5
6
3
1
2
1
Fig. 1: Product design
1
Pneumatic port; identification on the
product
2
Plug for electrical connection
3
Display
4
[A] key
5
[Edit] key
6
[B] key
Festo — SFAH — 2023-08c
Product overview
7
4.1.2 Display components
2
1
3
3
4
Fig. 2: LCD display
1
Status information
2
Main display, e. g. measured value
3
Output display
3
Output display
4
Sub-display, e.g. unit
Symbols on the display
Example for LCD display Description
Output display
‘OutA’ Switching output OutA selected/activated, flashes with active IO-
Link
‘OutA’ Switching output OutA set
‘OutB’ Switching output OutB selected/activated
‘OutB’ Switching output OutB set
‘Pulse’ Analogue output for volume pulse and mass pulse selected
Anlg’ Analogue output for flow rate selected/activated
Status information
‘Lock’ Security code activated
‘Spec’ Special menu selected
‘Option’ Parameters that influence the measured value display have been
changed from the factory setting: reference condition (standard) or
gas
Tab. 3: Output display and status information
8
Festo — SFAH — 2023-08c
Product overview
Example for LCD display Description
Main display Sub-display
Measured value indicator and unit in RUN mode
‘–0.53 ‘L.Min’ Measured value indicator and unit
Menu items for the OutA and OutB switching outputs
‘Edit’ ‘bin’ EDIT menu for the switching outputs
‘_|¯’ ‘Fctn’ Threshold value comparator
‘_|¯|_’ ‘Fctn’ Window comparator
d_|¯|_’ ‘Fctn’ Auto difference monitor
‘18.0’ ‘SP’ Switching point value
‘1.80 ‘SP.Lo Value of lower switching point
‘6.45’ ‘SP.Hi Value of upper switching point
‘0.50 ‘HY’ Hysteresis value
‘18’ ‘t.obS’/‘MSEC’1) Time interval for determination of the signal change,
which is used to establish the reference value.
‘0.25 d.SP’ Threshold value for determination of the monitoring
range
‘N/O’ ‘LOGC’ Switching characteristics of the switching outputs:
‘NO’ = N/O contact, ‘NC’ = N/C contact
‘bLUE’ ‘COLR’ Display colour
Extreme values, SHOW mode only
‘1.64’ MIN’ Minimum measured value since switching on the
supply voltage or since the last reset
‘8.50 ‘MAX Maximum measured value since switching on the
supply voltage or since the last reset
‘20.8’ ‘AVER’ Average of the flow rate measurement, filter time con-
stants
Additional settings
‘100’ ‘PULS’ Duration of the volume pulse or mass pulse at the
output
Analogue output
‘Edit’ ANLG’ EDIT menu for the analogue output
‘0...10’ ‘Out’/‘V1) Output function of the analogue output

Produktspecifikationer

Varumärke: Festo
Kategori: Inte kategoriserad
Modell: SFAH-100U-Q8S-PNLK-PNVBA-L1

Behöver du hjälp?

Om du behöver hjälp med Festo SFAH-100U-Q8S-PNLK-PNVBA-L1 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Festo Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer