INSTALLATION OF THE
ADK ADAPTER PLUG
ELECTRICAL SHOCK HAZARD. Turn off power to the area where you
will install this unit at the circuit breaker or fuse box before beginning
installation. Failure to turn off the power before installation may result in
serious electrical shock, injury or death. Do not restore power until all
Smoke Alarms are completely installed.
•
Installation of this unit must conform to the electrical codes in your
area; Article 760 of NFPA 70 (NEC), NFPA 72, NFPA 101; SBC (SBCCI);
UBC (ICBO); NBC (BOCA); OTFDC (CABO), and any other local or
building codes that may apply. Wiring and installation must be per-
formed by a licensed electrician. Failure to follow these guidelines
may result in injury or property damage.
•
This unit must be powered by a 24-hour, 120VAC
pure sine wave
60Hz
circuit. Be sure the circuit cannot be turned off by a switch, dimmer,
or ground fault circuit interrupter. Failure to connect this unit to a
24-hour circuit may prevent it from providing constant protection.
For all other Smoke Alarm information, instructions and warnings, refer to the
Smoke Alarm User’s Manual.
Independent evaluation of the
Adapter Plug and interconnect
compatibility was performed by
Intertek, a division of ETL SEMKO.
© 2007 BRK Brands, Inc., a Jarden Corporation company (NYSE: JAH)
3901 Liberty Street Road, Aurora, IL 60504-8122
All rights reserved.
Consumer Affairs: (800) 323-9005 • www.firstalert.com • www.brkelectronics.com
US Patent No.: 6,641,433 B2
BRK®is a registered trademark of BRK Brands, Inc.
First Alert®is a registered trademark of the First Alert Trust.
Lifesaver®is a registered trademark of Fyrnetics, Inc.
Printed in Mexico M08-0126-001 H06/07
INCOMPATIBLE POWER CONNECTORS:
DO NOT ATTEMPT
INSTALLATION
INSTALLATION INSTRUCTIONS
1. V
erify which MODELS are installed in your system to determine if they are
compatible with the ADK Adapter Plug (see part C below).
2. T
urn off AC power.
3. Remove unit. Remove old mounting bracket.
4. Install new mounting bracket (see part A below).
5. Connect the black end of the ADK Adapter Plug to the existing power
connector (connect part C to part D as shown below).
NOTE: There may not be enough room for the Adapter Plug and additional
wiring to fit in the junction box. If not, the old power connector must be
removed and replaced with a First Alert
®Power Connector.
6. Connect the other end of the Adapter Plug to the appropriate Smoke Alarm
(connect part C to part B as shown below).
7. Check all connections. Make sur
e all plugs are completely connected and
snapped together. Ensure the Adapter Plug is securely connected to the
existing Power Connector.
8. Install the base of the Smoke Alarm to the mounting bracket.
9. Restore power to the junction box.
10. Test each Smoke Alarm. Press and hold the test button until the unit alarms.
When testing a series of interconnected units you must test each unit
individually. Make sure all units alarm when each one is tested.
NOTE:
NOTE: Adapter Plug can be used on KIDDE/FYRNETICS/LIFESAVER®
Models manufactured on or before January 1, 2004.
COMPATIBLE BRK®AND FIRST ALERT®MODELS
All of the listed BRK®Alarms are compatible with the listed KIDDE/
FYRNETICS/LIFESAVER®Alarms and will work with the enclosed Adapter
Plugs.
BRK®Alarms
4120, 9120 Series – AC, AC/DC Ion, Silence
5919 – AC Photo
2002RAC – AC/DC Photo
7010 Series – AC, AC/DC Photo, Silence
SC6120B, SC9120B – AC/DC Smoke/CO Combo
HD6135FB – Heat Alarm
RM3 – Auxiliary Relay
KIDDE/FYRNETICS/LIFESAVER ®
1235 Series – AC Ion
1275 Series – AC/DC Ion, Hush
1285 Series – AC/DC Ion, Escape Light
1276 – AC/DC Ion, Hush, Front-Loading Battery
PE120E, PE120 – AC/DC Photo
PI2000 – AC/DC Ion/Photo
HD135F – Heat Alarm
• Maximum of 18 units total may be interconnected, (Maximum of 12
Smoke Alarms plus 6 other devices). Check for model numbers above.
A
B
C
D
NOTE: ADAPTER PLUG CANNOT BE USED TO CONNECT
KIDDE CARBON
MONOXIDE ALARMS.
THE ABOVE MODELS OF
KIDDE/FYRNETICS/LIFESAVER®
ARE THE ONLY
MODELS THAT MAY BE INTERCONNECTED USING ONE OF THE ADAPTER
PLUGS INCLUDED. IF THE MODEL IS NOT LISTED, IT MUST BE REMOVED
FROM THE SYSTEM.
3055574
RECOGNIZED
COMPONENT
CONFORMS TO
UL STANDARD 1977
The Parts of This Installation
Adapter Plug (ADK) Diagram for
KIDDE/FYRNETICS/LIFESAVER®Models:
White
Orange
Black
Side View
Plug Pin
V iew
NOTE: Twist tie should not be removed.
KIDDE
NOTE ROUND HOLES
A Mounting Bracket
B BRK® 4120, 9120 Series
Smoke Alarm
C ADK Adapter
D Existing compatible
power connector
Electrical Rating:
120V AC, 100mA Maximum
Not for Current Interruption
Produktspecifikationer
Varumärke: | First Alert |
Kategori: | Rökdetektor |
Modell: | ADK-12 |
Behöver du hjälp?
Om du behöver hjälp med First Alert ADK-12 ställ en fråga nedan och andra användare kommer att svara dig
Rökdetektor First Alert Manualer
24 December 2024
24 December 2024
24 December 2024
24 December 2024
14 Oktober 2024
2 Oktober 2024
29 September 2024
24 September 2024
24 September 2024
24 September 2024
Rökdetektor Manualer
- Rökdetektor Bosch
- Rökdetektor IKEA
- Rökdetektor Siemens
- Rökdetektor Abus
- Rökdetektor Alecto
- Rökdetektor AngelEye
- Rökdetektor Flamingo
- Rökdetektor Brennenstuhl
- Rökdetektor Nedis
- Rökdetektor Pyle
- Rökdetektor Vivanco
- Rökdetektor Blaupunkt
- Rökdetektor Elro
- Rökdetektor EMOS
- Rökdetektor KlikaanKlikuit
- Rökdetektor Ei Electronics
- Rökdetektor Hama
- Rökdetektor Smartwares
- Rökdetektor Marquant
- Rökdetektor Steren
- Rökdetektor ESYLUX
- Rökdetektor Malmbergs
- Rökdetektor Olympia
- Rökdetektor Dahua Technology
- Rökdetektor Kidde
- Rökdetektor Netatmo
- Rökdetektor Hager
- Rökdetektor FireAngel
- Rökdetektor Chacon
- Rökdetektor Sygonix
- Rökdetektor TFA
- Rökdetektor Clas Ohlson
- Rökdetektor Konig
- Rökdetektor BRK
- Rökdetektor Busch-Jaeger
- Rökdetektor Bavaria
- Rökdetektor Gira
- Rökdetektor Jung
- Rökdetektor FireX
- Rökdetektor DSC
- Rökdetektor Fito
- Rökdetektor FirstAlert
- Rökdetektor Fibaro
- Rökdetektor Nexa
- Rökdetektor Satel
- Rökdetektor EQ3
- Rökdetektor Homematic IP
- Rökdetektor Calex
- Rökdetektor Mobeye
- Rökdetektor FireHawk
- Rökdetektor X-Sense
- Rökdetektor Stabo
- Rökdetektor Chuango
- Rökdetektor ORNO
- Rökdetektor Mercury
- Rökdetektor Heatit
- Rökdetektor Ferguson
- Rökdetektor Fito Profi-line
- Rökdetektor Kogan
- Rökdetektor Gloria
- Rökdetektor H-Tronic
- Rökdetektor System Sensor
- Rökdetektor Schwaiger
- Rökdetektor Inovonics
- Rökdetektor Pyrexx
- Rökdetektor EQ-3
- Rökdetektor Pristine
- Rökdetektor Cavius
- Rökdetektor Jemay
- Rökdetektor Pentatech
- Rökdetektor Mircom
- Rökdetektor WisuAlarm
- Rökdetektor BRK DICON
- Rökdetektor Cordes
- Rökdetektor STI
- Rökdetektor Deltronic
- Rökdetektor Insafe
- Rökdetektor Gewiss
- Rökdetektor No-Flame
- Rökdetektor Egardia
- Rökdetektor GEV
- Rökdetektor Frient
- Rökdetektor Qolsys
- Rökdetektor SAVS
Nyaste Rökdetektor Manualer
31 December 2025
31 December 2025
31 December 2025
31 December 2025
30 December 2025
28 December 2024
28 December 2024
28 December 2024
28 December 2024
22 December 2024