R32
REFRIGERANT
This Air Conditioner contains and
operates with ref rigerant R32.
THIS PRODUCT MUST ON BE INSTALLED OR SERVICEDLY
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
Before using this product, read these instructions
thoroughly. Also, keep this manual for future
reference, together with the installation manuals for
the indoor and outdoor units.
PART No. 9378532113
MODEL:
□ AGTG09KVCA
□ AGTG12KVCA
□ AGTG14KVCA
* Please check the model name.
(Refer to the rating label.)
OPERATION MANUAL
AIR CONDITIONER
Floor type
En-1
1. SAFETY PRECAUTIONS
To prevent personal injury or property damage, read this section
carefully before you use this product, and be sure to comply
with the following safety precautions.
Incorrect operation due to failure to follow the instructions may
cause harm or damage, the seriousness of which is classied
as follows:
WARNING
This mark warns of death or serious injury.
CAUTION
This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this product uses a low
burning velocity material. If the refrigerant is leaked
and exposed to an external ignition source, there is a
risk of re.
CAUTION
This symbol shows that the operation manual should
be read carefully.
CAUTION
This symbol shows that a service personnel should
be handling this equipment with reference to the
installation manual.
CAUTION
This symbol shows that information is available such
as the operation manual or installation manual.
WARNING
• When installing this product to an unventilated area,
pay attention to prevent re and explosion caused
by the stagnated gas in case of refrigerant leakage.
(For products which contain more than 1.842 kg
refrigerant.)
• This product contains no user-serviceable parts.
Always consult authorized service personnel for
repairing, installation, and relocation of this product.
Improper installation or handling will cause leakage,
electric shock, or re.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning o󰀨 the
electrical breaker or disconnecting the power plug.
Then consult authorized service personnel.
• Take care not to damage the power supply cable.
If it is damaged, it should be replaced only by
authorized service personnel in order to avoid a
hazard.
• If a refrigerant leakage is suspected, all naked
ames shall be removed or extinguished, and consult
authorized service personnel.
• In the event of a thunder storm or any prior sign
of a lightning strike, turn o󰀨 the air conditioner via
the remote controller, and refrain from touching the
product or the power source to prevent any electrical
hazards.
• This product shall be stored in a room without
continuously operating ignition sources (for example:
open ames, an operating gas appliance or an
operating electric heater).
• This product shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• This product shall be stored so as to prevent
mechanical damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit,
pipes shall be covered with the wall hook bracket for
protection.
Do not move this product by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
• This product is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision
or instruction concerning use of this product by a
person responsible for their safety. Children should
be supervised to ensure that they do not play with this
product.
• Dispose of the packing materials safely. Tear and
dispose of the plastic packing bags so that children
cannot play with them. There is danger of su󰀨ocation
if children play with the original plastic bags.
Contents
1. SAFETY PRECAUTIONS 1 ..........................................
2. PREPARATION ......................................................... 2
3. NAME OF PARTS 3 .....................................................
3.1. Indoor unit 3 ........................................................
3.2. Remote controller 3 .............................................
3.3. Battery loading 5 .................................................
4. BASIC OPERATIONS 5 ...............................................
5. AIRFLOW SETTINGS 5 ...............................................
5.1. Fan speed setting 5 .............................................
5.2. Airow direction setting .................................... 6
6. TIMER OPERATIONS 6 ...............................................
6.1. Weekly timer 7 .....................................................
6.2. On timer or O󰀨 timer ......................................... 7
6.3. Program timer 7 ...................................................
6.4. Sleep timer 7 ......................................................
7. ENERGY SAVING OPERATION 8 ...............................
7.1. Economy operation 8 ..........................................
7.2. Fan control for energy saving 8 ...........................
8. OTHER OPERATIONS 8 .............................................
8.1. Powerful operation 8 ...........................................
8.2. Outdoor Unit Low Noise operation 8 ...................
8.3. 10 °C Heat operation 8 ........................................
9. SETTINGS ON INSTALLATION 9 ................................
9.1. Remote controller custom code setting 9 ............
10. CLEANING AND CARE 9 .............................................
11. GENERAL INFORMATION ..................................... 11
12. OPTIONAL PARTS ................................................. 11
12.1. Wired remote controller 11 ..................................
13. TROUBLESHOOTING ............................................ 11
[Original Instructions]
En-2
WARNING
Do not install the unit in area lled with mineral oil
such as a factory or area containing a large amount of
splashed oil or steam such as a kitchen.
• Do not start or stop the operation of this product by
inserting or pulling out the power plug, or by turning
on or o󰀨 the circuit breaker.
Do not use ammable gases near this product.
Do not expose yourself directly to the cooling airow
for many hours.
Do not insert your ngers or any other objects into
outlet port or inlet port.
• Do not operate with wet hands.
• Do not use means to accelerate the defrosting
process or to clean this product, other than those
instructed in this manual.
• Do not pierce or burn.
• Do not splash water over the product, to avoid safety
hazards.
CAUTION
• Provide occasional ventilation during use.
Always operate this product with air lters installed.
• Ensure that any electronic equipment is at least 1 m
(40 in) away from this product.
• After a long period of use, ensure to get the mounting
of the indoor unit checked to prevent this product from
falling down.
The airow direction and the room temperature should
be carefully considered when you use this product in a
room with infants, children, elderly or sick persons.
• Keep the surroundings of the outdoor unit clean and
tidy, and do not place items around it. Any objects
blocking or entering from the outlet ports may cause
product malfunction.
Do not direct the airow atreplaces or heating apparatus.
Do not block or cover the intake grille and the outlet port.
Do not apply any heavy pressure to radiator ns.
• Do not climb on or sit, place objects on, or hang
objects from this product.
• Do not place any other electrical products or
household belongings under this product. Dripping
condensation from this product might get them wet,
and may cause damage or malfunction of your
property.
• Do not use this product for preservation of food, plants,
animals, precision equipment, art work, or other objects.
This may cause quality deterioration of those items.
Do not expose animals or plants to the direct airow.
• Do not drink the drainage from the air conditioner.
• Do not pull the power supply cable.
Do not touch the aluminum ns of heat exchanger
built-in this product to avoid personal injury when you
maintain the unit.
• Do not stand on unstable steps when operating or
cleaning this product. It may overturn and can cause
injury.
Do not use ammable substances (such as pesticides
and hair sprays). Doing so may cause an electric
shock, re or wrong detection by the refrigerant
sensor.
• This product is equipped with a refrigerant leakage
sensor. Do not install the product at a location lled
with smoke, gases or chemicals.
CAUTION
Do not turn o󰀨 the breaker unless the product is under
repair, inspection, or cleaning. Otherwise, the sensor
is unable to detect refrigerant leak.
This product contains uorinated greenhouse gases.
2. PREPARATION
WARNING
• Take care to prevent infants and young children from
accidentally swallowing the batteries.
CAUTION
If leaking battery uid comes in contact with your skin,
eyes, or mouth, immediately rinse with plenty of clean
water, and consult your physician.
• Exhausted batteries must be removed immediately,
and be disposed according to the local laws and
regulations of your region.
• If the remote controller is to be stored unused for a long
period, the batteries should be removed.
• Batteries are to be inserted with the corrected polarity.
• Be aware of the risk of terminals of the battery-operated
appliance or battery being short-circuited by metal
objects.
• Do not attempt to recharge dry batteries.
• Do not use dry batteries that has been recharged.
• The supply terminals must not be short-circuited.
• Do not expose the remote controller or battery to
excessive temperatures.
Indoor unit accessories
Please check that the following accessories are included.
Remote controller Remote controller
holder
Tapping screws
Batteries Air cleaning lters
Remote controller holder installation
321
Insert
Screws Slide up
En-3
WARNING
• Keep out of reach of children. Swallowing the batteries
can lead to chemical burns, perforation of soft tissue,
and death. Severe burns can occur within 2 h of
ingestion. Seek medical attention immediately.
3. NAME OF PARTS
CAUTION
For appropriate signal transmission between the remote
controller and the indoor unit, keep the signal receiver
away from the following items:
- Direct sunlight or other strong lights
- Flat-panel television screen
In rooms with instantaneous uorescent lights, such as
inverter type ones, the signal may not be transmitted
properly. In such a case, consult the store of purchase.
3.1. Indoor unit
For Manual Auto operation
and Filter indicator reset
(Refer to page 13.)
Airow Direction
Louver
Air lter
Indicator lamps *2)
Remote controller
signal receiver
Drain hose
Air cleaning
lter
Vertical
louver
(behind Airow
Direction Louver
and Damper)
Front panel
Air Outlet Selection switch
(Refer to page 6.)
Rope
Intake grille
*1)
Damper
*1) Before starting operation, make sure that the intake grille is closed
completely. Incomplete closing may a󰀨ect the proper function or
performance of the product.
*2) Indicator lamps light in the following conditions. It cannot see when
the indicator lamp is o󰀨.
Name Color Operation or condition
TIMER Orange Timer operation
OPERATION Green Normal operation
ECONOMY Green Economy operation
10 °C Heat operation
3.2. Remote controller
When you use the optional remote controller, the appearance
and the operation procedure may di󰀨er.
For details, please refer to the operation manual of each remote
controller.
: The setting must be done while the setting screen is displayed
for each function.
: The button is controllable only when the air conditioner is
operating.
For Basic operations ..................... Refer to page 5.
Starts or stops the air conditioner operation.
Changes the operation mode.
Adjusts the setting temperature.
For Outdoor Unit Low Noise operation
Refer to page 8. ...
Activates or deactivates the Outdoor Unit Low
Noise operation.
For Energy saving operation ........ Refer to page 8.
Activates or deactivates the Economy
operation.
Do not press this button in normal use.
It starts the test run (for use by authorized service personnel only).
NOTES: If the test run starts unintentionally, press to quit the test
run.
For 10 °C Heat operation .............. Refer to page 8.
Activates the 10 °C Heat operation.
CAUTION
• To prevent malfunction or damage of the remote
controller:
- Place remote controller at where will not be
exposed to direct sunlight or excessive heat.
- Remove batteries if the product is not going to be
used for an extended period.
• Obstacles such as a curtain or wall between the
remote controller and the indoor unit may a󰀨ect the
appropriate signal transmission.
• Do not apply strong shocks to the remote controller.
• Do not pour water on the remote controller.
En-5
3.3. Battery loading
Battery type: R03/LR03/AAA x 2
5
7
6
4
8
1
2
3
1
~
3
Put batteries as shown in the gure above.
4
Press to start clock setting.
5
Press
( )
to set day of the week (Monday
to Sunday).
* By pressing , the time indicator can be
changed from a 24-hour to a 12-hour clock.
6
Press to continue.
7
Press
( )
to set the clock.
Press the buttons to change the clock by a minute.
Press down the buttons to change the clock by 10 minutes.
8
Press to complete the setting.
Be close to the indoor unit. If you press the button from a
distance, settings may not be properly sent.
NOTES:
Use specied type of batteries only.
Do not mix di󰀨erent types or new and used batteries together.
Batteries can be used about 1 year in ordinary use.
If the remote control range noticeably shortens, replace the
batteries, and press as shown in page 4.
4. BASIC OPERATIONS
3 steps to start operation
1. Press to start or stop the operation.
2. Press to select the operation mode.
The operation mode changes as follows.
AUTO COOL DRY FAN HEAT
3. Press to set the desired temperature.
The temperature changes by 0.5 °C increments.
Temperature setting range
Auto/Cooling/Dry 18.0 to 30.0 °C
Heating 16.0 to 30.0 °C
NOTES:
In the Cooling or Dry mode, set the temperature lower than the
current room temperature.
In the Cooling mode, the indoor unit fan may stop from time to time
to perform Fan control for energy saving that enables power-saving
operation by stopping the rotation of the indoor unit fan when the
outdoor unit is stopped.
In initial setting, this function is activated.
To deactivate the function, consult the installer or authorized service
personnel.
In the Heating mode,
- set the temperature higher than the current room temperature.
- at the beginning of the operation, the indoor unit fan rotates at very
low speed for 3-5 minutes.
- the Automatic defrosting operation overrides the Heating operation
when necessary.
In the Fan mode, temperature control is not available.
Temperature unit switching
1. Press until only the clock is displayed.
2. Press down for more than 5 seconds.
The current temperature unit will be displayed. (Factory setting: °C)
3. Press to switch the temperature unit. (°C °F)
4. Press to nish the setting.
If you do not press the button for 30 seconds, the displayed
temperature unit will be set.
5. AIRFLOW SETTINGS
5.1. Fan speed setting
) Press to control the fan speed.
The fan speed changes as follows.
(Auto) (High) (Med) (Low) (Quiet)
When is selected, the fan speed depends on the operating
condition.
To increase the air cleaning e󰀨ect, set the fan speed to High.
En-8
7. ENERGY SAVING OPERATION
7.1. Economy operation
It saves more electricity than other operation modes by changing the set
temperature to a moderate setting.
) Press to activate/deactivate the Economy
operation.
[ ] indicator on the indoor
unit will turn on.
Indicator Lamp
TIMER OPERATION ECONOMY
: Lighting : OFF
Operation
mode Room temperature
Cooling/Dry Few degrees higher than the set temperature
Heating Few degrees lower than the set temperature
NOTES:
In the Cooling, Heating, or Dry mode, the maximum output of this
operation is approximately 70 % of usual operation.
This operation cannot be performed during the temperature
monitoring by the Auto mode.
7.2. Fan control for energy saving
In the Cooling operation, when the room
temperature reaches the set temperature, the
indoor unit fan rotates intermittently to save
power. (This function is deactivated at the time of
purchase.)
To change the setting, use the following
steps;
1. Press until only the clock is displayed on the remote
controller display.
2. Press down for more than 5 seconds.
The current Fan Control status ( ) is displayed.
3. Press to switch between activated ( ) or
deactivated ( ).
4. Press to send the setting to the indoor unit.
The display will return to the original screen.
NOTES: If you do not press any buttons for 30 seconds after is
displayed, will turn o󰀨. In this case, repeat the setting from
step 2.
8. OTHER OPERATIONS
8.1. Powerful operation
In the Powerful operation, the air conditioner will operate at maximum
power and strong airow to cool down or warm up the room quickly.
NOTES: In multi connection, this function cannot be used.
) Press to activate/deactivate the Powerful operation.
When activated, the indoor unit will emit 2 short beeps.
When deactivated, the indoor unit will emit 1 short beep.
The Powerful operation will be turned o󰀨 automatically in the following
situations:
The Powerful operation runs for a certain amount of time and the
room temperature reaches the set temperature in the Cooling, Dry,
or Heating mode.
20 minutes after the Powerful operation has started.
NOTES:
The airow direction and the fan speed are controlled automatically.
The Powerful operation cannot be performed simultaneously with
Economy operation.
The Powerful operation overrides the following operations. If
the following operations are set, they will start after the Powerful
operation nishes.
- Outdoor Unit Low Noise operation
- Energy Saving program
If the wired remote controller (optional) is connected, this function is
restricted.
8.2. Outdoor Unit Low Noise operation
The Outdoor Unit Low Noise operation lowers noise from the outdoor
unit. During this operation, the rotation number of the compressor
decreases and the outdoor unit fan rotates slowly.
NOTES: In multi connection, this function cannot be used.
) Press to activate/deactivate the Outdoor Unit Low
Noise operation.
While the Outdoor Unit Low Noise operation is activated,
on the remote controller is displayed.
The setting is preserved even if the air conditioner is turned o󰀨.
NOTES:
This operation cannot be performed simultaneously with the Fan
mode, Dry mode, and Powerful operation.
If the wired remote controller (optional) is connected, this function is
restricted.
8.3. 10 °C Heat operation
10 °C Heat operation maintains the room temperature at 10 °C so as to
prevent the room temperature to drop too low.
) Press to activate the 10 °C Heat operation.
The indoor unit will emit 1 short beep and [ ] indicator on the
indoor unit will turn on.
) Press to turn o󰀨 the air conditioner.
[ ] indicator will turn o󰀨.
Indicator Lamp
TIMER OPERATION ECONOMY
: Lighting : OFF
NOTES:
During the 10 °C Heat operation, only is valid.
When the room temperature is warm enough, this operation will not
perform.
If the wired remote controller (optional) is connected, this function is
restricted.

Produktspecifikationer

Varumärke: Fujitsu
Kategori: Luftkonditionering
Modell: SET-AGTG14KVCA
Enhetsplacering: Aanrecht
Typ av operation: Knoppen
Färg på produkten: Zwart
Inbyggd display: Ja
Vikt: 2000 g
Bredd: 191 mm
Djup: 270 mm
Höjd: 353 mm
Vattennivåindikator: Ja
Förpackningens vikt: 2620 g
Förpackningens bredd: 240 mm
Djuppackning: 285 mm
Förpackningshöjd: 385 mm
Håll varm funktion: Ja
Lätt att städa: Ja
Tillgångar: 1000 W
Vattentankens kapacitet: 1.4 l
Automatisk avstängning: Ja
Kaffebryggare typ: Half automatisch
Kaffeinmatningstyp: Gemalen koffie
Reservoar för bryggkaffe: Kan
Kapacitet i koppar: 10 kopjes
Inbyggd kvarn: Nee
Justerbar kaffestyrka: Nee
Varmvattensystem: Nee
Antidroppfunktion: Ja
Avtagbar filterhållare: Ja
Göra kaffe: Ja
Att göra espresso: Nee
Gör cappuccino: Nee
Belyst på/av-knapp: Ja
Håll varm funktionslängd: 40 min
AC-ingångsspänning: 220-240 V
AC-ingångsfrekvens: 50/60 Hz
Typ produkt: Filterkoffiezetapparaat
Type beeldscherm: Analoog
Flera drinkar: Nee

Behöver du hjälp?

Om du behöver hjälp med Fujitsu SET-AGTG14KVCA ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Fujitsu Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer