GE SPLK10N01A Bruksanvisning

GE Torktumlare SPLK10N01A

Läs nedan 📖 manual på svenska för GE SPLK10N01A (4 sidor) i kategorin Torktumlare. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/4
31-8000282 Rev. 5 08-23 GEA
Tools you will need:
# 0 or #00 phillips screwdriver flat head scredriver
1+1 KIT (Model SPLK10N01A) contents:
1 - Gateway (Model SPLG10N01P)
1 - Sensor (2 AAA Batteries installed) (Model SPLS10N01P)
1 - USB-C Cable (1 ft.) 1 - USB-A power plug
1+3 KIT (Model SPLK30N01A) contents:
1 - Gateway (Model SPLG10N01P)
3 - Sensors (each sensor has 2 AAA Batteries installed) (Model
SPLS10N01P)
1 - USB-C Cable (1 ft.) 1 - USB-A power plug
Product Specications:
Gateway (WiFi)
Voltage* . . . . . . . . DC 5V (Input) Frequency . . . . . . .2.4 GHz
* Use UL listed supply with max output power of 5 W (included).
Water Leak Sensor
Voltage. . . . . . . . . . . . . . . . . . . .DC 3V (2x AAA = 1.5V x 2)
Frequency . . . . . . . . . . . . . . . . .2.4 GHz
Waterproof Rating . . . . . . . . . . .IP64
1A Install the SmartHQ App
Scan QR Code to install the SmartHQ app.
Launch the SmartHQ app and register your account.
1B Install the SmartHQ Management App
(commercial application only)
Select and scan the appropriate QR Code for your device to install
the SmartHQ Management app.
iOS - QR Code Android - QR Code
Launch the SmartHQ Management app and register your account.
2Powering Your Sensor
Hold the sensor in one hand, label facing up.
Pinch the battery insulator (pull tab) close to
the battery cover and slowly pull as shown
(sideways, parallel to the battery cover).
Discard the pull tab. Place the sensor aside
and proceed to Step 3, Powering your
Gateway.
7Replacing the AAA Batteries
When it is time to replace the batteries, use only new alkaline non-re-
chargeable AAA batteries.
Locate a clean table to work on and have the
tools ready.
Use a #0 or #00 phillips screwdriver and remove
one of the battery cover screws. Carefully place
the screw to the side.
Loosen the other screw ~3 turns, keep this
screw attached to the cover.
Place the sensor on the table with the
label facing up and place one hand on the
sensor as shown.
Place the flat head screwdriver under the
screw head and lift up the screw head. The battery
cover will lift up as well.
Remove the battery cover.
NOTE: The cover is designed to fit tightly in the
housing so this may take some force.
Install 2 new non-rechargeable AAA batteries
Replace the battery cover. Press down the cover
and then tighten the screws. DO NOT OVER TIGHTEN.
CAUTION Use care and follow the battery installation
instructions carefully to maintain the water tightness design of your
Water Leak Sensor.
Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries in accordance with local battery disposal
procedures.
4Connect your Gateway
Open the SmartHQ app and touch the “+” located at the top right-
hand corner of the app homepage.
Select GE brand.
Your Gateway should appear at the top. Touch Connect. Follow
the instructions from the app to complete the connection of your
gateway and to pair your sensor(s).
To avoid confusion, after pairing your sensor, it is recommended
that you give each sensor a custom nickname and place the sensor
in its appropriate location before proceeding to the next sensor.
3Powering your Gateway
Plug the USB-C cable (included) into
the USB-C port on the Gateway.
Plug the USB connector into a USB-A
power plug (included). Use UL listed supply
with max output power rating of 5 W.
5Placing your Sensor
Your sensor can be placed in locations where a
potential water leak may occur. For example, in your
laundry room, under your kitchen sink pipes, near
your water heater, etc.
For a water heater with catch pan:
Place the double sided tape (included) on the back of
the sensor. Remove the backing and place the sensor against your water
heater with the sensor probes on the bottom and the button at the top.
6Water Leak Notication/Alert
When the Sensor detects a water leak, a signal is sent to the
Gateway. You will then receive a notification/alert on your mobile
device that, A leak was detected”.
To clear the Leak from the app, remove the sensor from the leak
source and close and open the app after approximately 1 minute.
Installation
Instructions
Water Leak Detector
Congratulations on choosing the Water Leak Detector powered by SmartHQ
TM. For more information or assistance,
visit GEAppliances.com/connect or Call 800.220.6899.
USB
©2023 GE Appliances, a Haier company
Regulatory Module Integration Instructions
The Gateway device has been granted modular approval for a mobile application. And
the Water Leak Sensor communicates with the Gateway via BLE (Bluetooth Low Energy)
PHVK7KH*DWHZD\LVFHUWL¿HGE\)&&,&%OXHWRRWK6,*7KH:DWHU/HDN6HQVRULQFOXGHV
)&&,&%OXHWRRWK6,*FHUWL¿HGPRGXOHE\*($SSOLDQFHV7KHGHVFULSWLRQVDUHDVIROORZV
Product Name: Gateway for Water Leak Sensor, Model: FCC ID: SPLG10N01P
ZKJ-WCATA010 10229A-WCATA010, IC:
 3URGXFW1DPH:DWHU/HDN6HQVRU,QFOXGLQJDFHUWL¿HGPRGXOH0RGHO
SPLS10N01P CONTAINS FCC ID: ZKJ-BLEA004,
CONTAINS IC: 10229A-BLEA004
The Gateway and Water Leak Sensor devices comply with FCC/IC regulations.
'HYLFH&ODVVL¿FDWLRQV
6LQFHKRVWGHYLFHVYDU\ZLGHO\ZLWKGHVLJQIHDWXUHVDQGFRQ¿JXUDWLRQVPRGXOHLQWHJUDWRUV
VKDOOIROORZWKHJXLGHOLQHVEHORZUHJDUGLQJGHYLFHFODVVL¿FDWLRQDQGVLPXOWDQHRXV
transmission, and seek guidance from their preferred regulatory test lab to determine how
regulatory guidelines will impact the device compliance. Proactive management of the
regulatory process will minimize unexpected schedule delays and costs due to unplanned
testing activities.
The module integrator must determine the minimum distance required between their host
GHYLFHDQGWKHXVHU¶VERG\7KH)&&SURYLGHVGHYLFHFODVVL¿FDWLRQGH¿QLWLRQVWRDVVLVWLQ
PDNLQJWKHFRUUHFWGHWHUPLQDWLRQ1RWHWKDWWKHVHFODVVL¿FDWLRQVDUHJXLGHOLQHVRQO\VWULFW
DGKHUHQFHWRDGHYLFHFODVVL¿FDWLRQPD\QRWVDWLVI\WKHUHJXODWRU\UHTXLUHPHQWDVQHDU
body device design details may vary widely. Your preferred test lab will be able to assist
in determining the appropriate device category for your host product and if a KDB or PBA
must be submitted to the FCC.
Note, the module you are using has been granted modular approval for mobile
applications. Portable applications may require further RF exposure (SAR) evaluations. It
is also likely that the host / module combination will need to undergo testing for FCC Part
UHJDUGOHVVRIWKHGHYLFHFODVVL¿FDWLRQ<RXUSUHIHUUHGWHVWODEZLOOEHDEOHWRDVVLVWLQ
determining the exact tests which are required on the host / module combination.
CAUTION
&KDQJHVRUPRGL¿FDWLRQVQRWH[SUHVVO\DSSURYHGE\WKHSDUW\
responsible for compliance could void the user’s authority to
operate the equipment.
)&&'H¿QLWLRQV
Portable:²$SRUWDEOHGHYLFHLVGH¿QHGDVDWUDQVPLWWLQJGHYLFHGHVLJQHGWR
be used so that the radiating structure(s) of the device is / are within 20 centimeters of the
body of the user.
Mobile:E²$PRELOHGHYLFHLVGH¿QHGDVDWUDQVPLWWLQJGHYLFHGHVLJQHGWREH
XVHGLQRWKHUWKDQ¿[HGORFDWLRQVDQGWRJHQHUDOO\EHXVHGLQVXFKDZD\WKDWDVHSDUDWLRQ
distance of at least 20 centimeters is normally maintained between the transmitter’s
radiating structure(s) and the body of the user or nearby persons. Per §2.1091d(d)(4) In
some cases (for example, modular or desktop transmitters), the potential conditions of use
RIDGHYLFHPD\QRWDOORZHDV\FODVVL¿FDWLRQRIWKDWGHYLFHDVHLWKHU0RELOHRU3RUWDEOH,Q
these cases, applicants are responsible for determining minimum distances for compliance
IRUWKHLQWHQGHGXVHDQGLQVWDOODWLRQRIWKHGHYLFHEDVHGRQHYDOXDWLRQRIHLWKHUVSHFL¿F
DEVRUSWLRQUDWH6$5¿HOGVWUHQJWKRUSRZHUGHQVLW\ZKLFKHYHULVPRVWDSSURSULDWH
Simultaneous Transmission Evaluation
This module has not been evaluated or approved for simultaneous transmission
as it is impossible to determine the exact multi-transmission scenario that a host
manufacturer may choose. Any simultaneous transmission condition established
through module integration into a host product must be evaluated per the requirements in
KDB447498D01(8) and KDB616217D01,D03 (for laptop, notebook, netbook, and tablet
applications).
These requirements include, but are not limited to:
7UDQVPLWWHUVDQGPRGXOHVFHUWL¿HGIRUPRELOHRUSRUWDEOHH[SRVXUHFRQGLWLRQVFDQEH
LQFRUSRUDWHGLQPRELOHKRVWGHYLFHVZLWKRXWIXUWKHUWHVWLQJRUFHUWL¿FDWLRQZKHQ
The closest separation among all simultaneous transmitting antennas is >20 cm,
Or
Antenna separation distance and MPE compliance requirements for ALL simultaneous
WUDQVPLWWLQJDQWHQQDVKDYHEHHQVSHFL¿HGLQWKHDSSOLFDWLRQ¿OLQJRIDWOHDVWRQHRIWKH
FHUWL¿HGWUDQVPLWWHUVZLWKLQWKHKRVWGHYLFH,QDGGLWLRQZKHQWUDQVPLWWHUVFHUWL¿HGIRU
portable use are incorporated in a mobile host device, the antenna(s) must be >5 cm
from all other simultaneous transmitting antennas.
$OODQWHQQDVLQWKH¿QDOSURGXFWPXVWEHDWOHDVWFPIURPXVHUVDQGQHDUE\SHUVRQV
FCC Part 15 Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.
NOTE: This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions.
1) This device may not cause harmful interference, and
2) This device must accept any interference received, including interference that may
cause undesired operation.
a. That module is limited to OEM installation ONLY.
b. That OEM integrators are responsible for ensuring that the end-user has no manual
instructions to remove or install module.
F 7KDWPRGXOHLVOLPLWHGWRLQVWDOODWLRQLQPRELOHRU¿[HGDSSOLFDWLRQVDFFRUGLQJWR3DUW
2.1091(b).
G 7KDWVHSDUDWHDSSURYDOLVUHTXLUHGIRUDOORWKHURSHUDWLQJFRQ¿JXUDWLRQVLQFOXGLQJ
SRUWDEOHFRQ¿JXUDWLRQVZLWKUHVSHFWWR3DUWDQGGLႇHUHQWDQWHQQD
FRQ¿JXUDWLRQV
e. That grantee shall provide guidance to the host manufacturer for compliance with
Part 15 subpart B requirements.
This device complies with Industry Canada’s license-exempt RSSs. Operation is subject to
the following two conditions:
 7KLVGHYLFHPD\QRWFDXVHLQWHUIHUHQFHDQG
2) This device must accept any interference, including interference that may cause
undesired operation of the device.
Information
Le présent appareil est conforme aux CNR d’Industrie Canada applicable aux appareils
radio exempts de licence.
Lexploitation est autorisée aux deux conditions suivantes:
1) l’appareil ne doit pas produire de brouillage, et
2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
Cet équipement est conforme aux limites d’exposition aux rayonnements énoncées pour
un environnement non contrôlé et respecte les règles les radioélectriques (RF) de la FCC
lignes directrices d’exposition et d’exposition aux frequencies radioélectriques (RF) CNR-
102 de l’IC. Cet équipement émet une énergie RF très faible qui est considérée conforme
VDQVpYDOXDWLRQGXGpELWG¶DEVRUSWLRQVSpFL¿TXH'$6
For the period of GE Appliances covers
One year
From the date of the original purchase
If the water leak detector and/or gateway fails due to a defect in materials or
workmanship, during the limited one year warranty, GE Appliances will replace your
product with a new or remanufactured product.
GEAppliances.com
Please contact 800.220.6899 to initiate warranty process.
What GE Appliances will not cover:
Ŷ )DLOXUHRIWKHSURGXFWLILWLVDEXVHGPLVXVHGDOWHUHGRU
used for other than the intended purpose.
Ŷ 'DPDJHWRWKHSURGXFWFDXVHGE\DFFLGHQWOLJKWQLQJILUH
oods or acts of God.
Ŷ ,QFLGHQWDORUFRQVHTXHQWLDOGDPDJHFDXVHGE\SRVVLEOH
defects with this appliance, its installation or repair.
Ŷ ,ISURGXFWUHPRYHGIURPRULJLQDOLQVWDOODWLRQORFDWLRQ
Ŷ 'DPDJHPDOIXQFWLRQRUIDLOXUHFDXVHGE\WKHXVHRIUHSDLU
service not approved by GE Appliances.
Ŷ 'DPDJHPDOIXQFWLRQRUIDLOXUHFDXVHGE\WKHXVHRI
unapproved parts or components.
EXCLUSION OF IMPLIED WARRANTIES
Your sole and exclusive remedy is product replacement as provided in this Limited Warranty. Any implied warranties, including
the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period
allowed by law.
For sale in the 50 United States and the District of Columbia only: This limited warranty is extended to the original purchaser and
any succeeding owner for products purchased for home use within the USA. Some states do not allow the exclusion or limitation of
incidental or consequential damages. This limited warranty gives you specific legal rights, and you may also have other rights which vary
from state to state. To know what your legal rights are, consult your local or state consumer affairs office or your state’s Attorney General.
For product purchased outside of the US, contact your dealer for Warranty and Service information.
Warrantor: GE Appliances, a Haier company
Louisville, KY 40225
Water Leak Detector powered by SmartHQ
TM
Limited Warranty
Staple your receipt here. Proof of the original purchase
date is needed to process your warranty.
©2023 GE Appliances, a Haier company
31-8000282 Rev. 5 08-23 GEA
Herramientas que necesitará:
Destornillador Phillips # 0 o #00 Destornillador de punta plana
Contenidos del KIT 1+1 (Modelo SPLK10N01A):
1 - Puerta de Enlace (Gateway) (Modelo SPLG10N01P)
1 - Sensor (2 Baterías AAA instaladas) (Modelo SPLS10N01P)
1 - Cable USB-C (1 pie) 1 - enchufe de corriente del USB-A
Contenidos del KIT 1+3 (Modelo SPLK30N01A):
1 - Puerta de Enlace (Modelo SPLG10N01P)
3 - Sensor (cada sensor cuenta con 2 Baterías AAA instaladas)
(Modelo SPLS10N01P)
1 - Cable USB-C (1 pie) 1 - enchufe de corriente del USB-A
Especicaciones del Producto:
Puerta de Enlace (WiFi)
Voltaje*……CC 5V (Entrada) Frecuencia…..2.4 GHz
* Use el suministro que figura en la lista de UL con máxima energía de salida de
5 W. (incluido)
Sensor de rdidas de Agua
Voltaje . . . . . . . . . . . . . . . . . . . . . . . . . . .CC 3V (2x AAA = 1.5V x 2)
Frecuencia . . . . . . . . . . . . . . . . . . . . . . . .2.4 GHz
Clasificación de Resistencia al Agua . . .IP64
1A Instale la Aplicación SmartHQ
• Escanee el Código QR para instalar la aplicación
SmartHQ.
• Lance la aplicación SmartHQ y registre su cuenta.
2Alimente el Sensor
Sostenga el sensor en una mano, con la etiqueta
hacia arriba.
Pellizque el aislante de la batea (tire de la
lengüeta), cierre la tapa de la batea y de forma lenta tire como se
muestra (hacia los laterales, de forma paralela a la tapa de la batería).
Descarte la lengüeta retirada. Coloque el sensor a un costado y proceda
al Paso 3, Alimentación de la Puerta de Enlace.
7Reemplazo de las Baterías AAA
Cuando sea hora de reemplazar las baterías, use sólo baterías AAA
nuevas alcalinas no recargables.
Use una mesa limpia para trabajar y tenga sus
herramientas preparadas.
• Use un destornillador de cabeza Phillips #0 o #00 y
retire uno de los tornillos de la tapa de las baterías.
Con cuidado, coloque el tornillo a un costado.
Afloje el otro tornillo dando ~3 giros,
mantenga este tornillo adherido a la tapa.
• Coloque el sensor sobre la mesa con la
etiqueta hacia arriba y coloque una mano
sobre el sensor, como se muestra.
• Coloque el destornillador de punta plana
debajo de la cabeza del tornillo y levante la cabeza del
tornillo. La tapa de las baterías se levantará también.
• Retire la tapa de las baterías.
NOTA: La tapa fue diseñada para calzar de forma
ajustada en la carcasa, de modo que podrá ser
necesario hacer algo de fuerza.
Instale las 2 baterías AAA no recargables nuevas. Vuelva a colocar la
tapa de las baterías. Presione la tapa hacia abajo y luego ajuste los
tornillos. NO AJUSTE EN EXCESO.
PRECAUCIÓN Tenga cuidado y siga las instrucciones de
instalación de las baterías para mantener el diseño de ajuste
impermeable contra el agua de su Sensor de Pérdidas de Agua.
Existe riesgo de explosión si la batería es reemplazada por una de
un tipo incorrecto.
Descarte las baterías usadas de acuerdo con los procedimientos
locales de descarte de baterías.
4Conecte la Puerta de Enlace (Cont.)
Abra la aplicación SmartHQ y presione el “+” ubicado en la esquina
superior derecha de la página principal de la aplicación.
• Seleccione la marca GE.
La Puerta de Enlace deberá aparecer en la parte superior. Presione
Connect (Conectar). Siga las instrucciones de la aplicación para completar
la conexión de la puerta de enlace y para emparejar el sensor(es).
Para evitar confusiones, luego de emparejar el sensor, se recomienda
dar a cada sensor un apodo personalizado y colocar el sensor en su
ubicación correspondiente antes de proceder con el siguiente sensor.
3Alimentación de la Puerta de Enlace.
• Enchufe el Cable USB-C (incluido) en el
puerto USB-C de la Puerta de Enlace.
• Enchufe el conector USB en el enchufe
de corriente del USB-A (incluido). Use el
suministro de la lista de UL con la calificación
de corriente de salida máxima de 5 W.
5Colocación del Sensor
El sensor se podrá colocar en ubicaciones donde
se pueda producir una pérdida de agua. Por
ejemplo: en su lavadero, debajo de las tuberías
de la bacha de su cocina, cerca de su calentador
de agua, etc.
Para un calentador de agua con bandeja antiderrames:
Coloque la cinta adhesiva sobre ambos lados (incluida) en la parte
trasera del sensor. Retire el protector y coloque el sensor contra el
calentador de agua con las sondas del sensor en la parte inferior y el
botón en la parte superior.
6Noticación/ Alerta de Pérdida de Agua
Cuando el Sensor detecte una pérdida de agua, se enviará una señal
a la Puerta de Enlace. Usted recibientonces una notificación/ alerta
en su dispositivo móvil de que: “Se detecuna pérdida”.
Para eliminar la Pérdida desde la aplicación, retire el sensor de la fuente de
la pérdida y cierre y abra la aplicacn luego de aproximadamente 1 minuto.
Instrucciones
de Instalación
Detector de Pérdidas de Agua
Felicitaciones por elegir el Detector de Pérdidas de Agua energizado por SmartHQ
TM. Para más información o asistencia, visite
GEAppliances.com/connect o llame al 800.220.6899.
USB
©2023 GE Appliances, a Haier company
1B Instale la Aplicación SmartHQ Management
(aplicación comercial únicamente)
Seleccione y escanée el Código QR apropiado para que se instale
en su dispositivo la aplicación SmartHQ Management.
IOS – Código QR Android – Código QR
Lance la aplicación SmartHQ Management y registre su cuenta.