Operation Manual English
Door control
Door control
MiniMax 3 S
MiniMax 3 S
EN conform: EN12453
(Safety in use of power operated doors)
English
Operation Manual
The door control DC MiniMax 3 S is designed for hold to run control of power operated
doors. The basic version is designed for hold to run operation only,
but it can be extended individually by an optional module.
Safety Directions
•In case of using DC MiniMax 3 S with a permanent mains connection, an all-pole main switch
with an appropriate back-up fuse must be provided.
•With three phase motor connection an external fuse in the main supply should be
max. 10A delayed.
•Before operation, check whether the permissible mains voltage range of the device corresponds
to the local mains voltage.
•With three phase motor connection it must have right phase rotation.
During installation, initial operation, maintenance and testing of the DC MiniMax 3 S it is
necessary to observe the safety and accident prevention regulations valid for the specific
application. Only trained electrical craftsmen should work on electrical equipment.
Technical Data
Model DC MiniMax 3 S
Supply voltage 230 VAC or 400 VAC
Frequency 50 Hz
Protection class IP 54
A max. 10 A
Operation temperature - 10 C° to + 55 C°
Operation Manual
English
Main board DC MiniMax 3S
Klemme
Spannungswahl
Stecksockel für
ext. 3- fach Taster
Einstelltaster
AUF - ZU
PE
Netzanschluss
Klemmleiste
Motor + Sicherheitskette
Potentialfreier Schaltkontakt
für Ampel oder Hoflicht
Stecksockel
Spiralkabel
Steckleiste
Selbsthaltung
AUF + ZU
Klemmleiste
Befehlsgeräte
Klemmleiste
Endschalter
Stecksockel
ZM SKS Modul
Connector
Control Devices (X3)
Connector
Spiral cord (X8)
Relais output (NO)
Traffic light (X9)
Connector
Comfort module
(X7)
OPEN/CLOSE
for installation of
limit switches only
Connector
External push-
button station
(X6)
Selector supply
voltage (X4)
Mains supply (X1)
Connector
Motor + Safety Switch (X2)
Self-Hold OPEN
Self Hold CLOSE
(X10) Connector
Limit Switches (X5)
Produktspecifikationer
Varumärke: | Geba Tronic |
Kategori: | Garageportöppnare |
Modell: | DC MiniMax 3 S |
Behöver du hjälp?
Om du behöver hjälp med Geba Tronic DC MiniMax 3 S ställ en fråga nedan och andra användare kommer att svara dig
Garageportöppnare Geba Tronic Manualer
14 September 2024
12 September 2024
12 September 2024
12 September 2024
11 September 2024
11 September 2024
10 September 2024
10 September 2024
10 September 2024
10 September 2024
Garageportöppnare Manualer
- Garageportöppnare Aperto
- Garageportöppnare Chamberlain
- Garageportöppnare Somfy
- Garageportöppnare Craftsman
- Garageportöppnare Marantec
- Garageportöppnare Liftmaster
- Garageportöppnare Abon
- Garageportöppnare Berner
- Garageportöppnare Hormann
- Garageportöppnare Sommer
- Garageportöppnare Novoferm
- Garageportöppnare Tormatic
- Garageportöppnare FAAC
- Garageportöppnare MAC
- Garageportöppnare Superrollo
- Garageportöppnare Univer
- Garageportöppnare Dickert
- Garageportöppnare DITEC
- Garageportöppnare Profitech
- Garageportöppnare Seculux
- Garageportöppnare Homentry
- Garageportöppnare Doorsystems
- Garageportöppnare Novotecnica
- Garageportöppnare Entrematic
- Garageportöppnare Skylink
Nyaste Garageportöppnare Manualer
8 Januari 2025
8 Januari 2025
7 Januari 2025
31 December 2025
18 Oktober 2024
30 September 2024
30 September 2024
30 September 2024
28 September 2024
23 September 2024