Please read this operation manual before using the air conditioner.
Keep this operation manual for future reference.
SPLIT TYPE ROOM AIR CONDITIONER
OPERATION MANUAL
0010535076
Contents
1
2-4
5
7
6.7
CAUTIONS
PARTS AND FUNCTIONS
OPERATION
MAINTENANCE
TROUBLE SHOOTING
HSU-07LEK113
HSU-09LEK113
HSU-12LEK113
HSU-09HEK113
HSU-12HEK113
HSU-07HEK113
HSU-18LEK113
HSU-24LEK113
HSU-18HEK113
HSU-24HEK113
HSU-07LEK13/R2
HSU-09LEK13/R2
HSU-12LEK13/R2
HSU-18LEK13/R2
HSU-24LEK13/R2
1
Parts and Functions
Remote controller
If the unit which you purchased has healthy function,follow it.If not,please ignore.
NOTE:
Cooling only unit do not have displays and functions related with heating
Outdoor Unit
Display board
1 42 35
Signal receiver hole
ON/OFF display
4
2
3
1
5
TIMER ON\OFF display
SLEEP display
Ambient temp.display
When receiving the remote
control signal, display the set
displayed and this room
time the room temperature is
temperature and in the rest
temperature is only for reference.
Note to the power failure resume:
press the sleep button ten times in five seconds and
enter function after hearing four sounds.And press
the sleep button ten times within five seconds and
leave this function after hearing two sounds.
TIMER ON-OFF display
8
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
(adjust up and down air flow
Don't adjust it manually)
(adjust left and right air flow)
Vertical blade
COOL\HEAT\Dry\AUTO display
14
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
1
2
3
4
1
2
3
Remove the battery cover;
Load the batteries as
illustrated. 2 R-03 batteries,
resetting key(cylinder);
Be sure that the loading
is in line with the" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
so the distance to the indoor unit should be shorter.
wireless telephone is installed in the type fluorescent lamp or
room, the receiver is apt to be disturbed in receivingthe signals,
Note:
Full display or unclear display during operation indicates the
ries have been used up.Please change batteries.
If the remote controller can't run normally during operation,
reload several minutes later.
batte
remove the batteries and
Remove the batteries in case unit won't be in usage for a long period.
If there are any displayafter taking-out, just need to press reset key
Hint:
Loading of the battery
please
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press will
change quickly.
After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
increase or decrease 1min. If the
button is kept pressed,time will
1
25..
SWING button
9. ON/OFF button
10. TIMER ON display
11. FAN SPEED display
LOW HI MED AUTO
12. LOCK display
13. SWING display
14. SLEEP display
Operation mode AUTO FANCOOL DRY
Remote controller
16. Operation mode display
18. POWER/SOFT display
19.
20.
TEMP display
21.
TIMER OFF display
22.
CLOCK display
23.
TEMP button
24.
FAN SPEED button
28. SET button
26. POWER/SOFT button
If pressed, the other buttons
be disabled .Press it once
again,lock will be cancelled.
29. LOCK
HEAT
17.Signal sending display
2
11
12
13
14
16 17
18
19
20
21
22
23
24
25
28
26
29
30
HEALTH AIRFLOW button
will
When the remote controller
30. RESET
button
button
appears abnormal,use a
sharp pointed article to press
this button to reset the remote
controller normal.
5. SLEEP button
Used to select CODE A or B
will be displayed on
explanation.
1.CODE
3. TIMER button
4. CLOCK button
8. MODE button
7. HOUR button
2.LIGHT button
Control the lightening and
the indoor
which
extinguishing of
LED display board.
LCD.
special
Please select A without
6
5
2
14
3
Inlet grille
Inlet
Air Purifying Filter (inside)
Outlet
Horizontal flap
6
4
2
15
3
5
2
1
5
3
6
4
7
7
SPEED
2
Operation
Operation
Mode
AUTO
Remote
Controller Note
COOL
DRY
HEAT
FAN
In DRY mode, when room temperature becomes
lower than temp.setting+2oC,unit will run intermittently
at LOW speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.
air conditioner automatically adjusts the fan speed
temperature.
When FAN is set to AUTO, the
according to room
In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.
Display
Board
next time,just press ON/OFF button and unit will run in previous status.
Remote controller can memorize each operation status. When starting it
AUTO COOL DRY FAN HEAT
2.Select operation mode
Press FAN SPEED button. For each press, fan speed
follows:
Press MODE button. For each press, operation mode
changes as follows:
Remote controller:
Remote controller:
Press button
Every time the button is pressed, temp.setting
increase 1o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1oC,if kept depressed, it will decrease
rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
LOW MED HI AUTO
1. Unit start
Press ON/OFF on the remote controller, unit starts.
TEMP+
TEMP-
TEMP+ TEMP-
/
Base Operation
Remote controller
Air Flow Direction Adjustment
Vertical flap
Pos.1 Pos.2 Pos.3
Pos.4 Pos.5 (Auto swing)
1.Status display of air flow
When restart after remote turning off, the remote
memorize the previous
Move the vertical blade by a knob on air
to adjust left and right direction referring to Fig.
2.Left and right air flow adjustment(manual)
Cautions:
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
adjusted to left or
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
conditioner
Emergency Operation:
temperature is below 16oC, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Emergency operation and test operation
Use this operation only when the remote controller
is defective or lost.
When the emergency operation switch is
pressed,the" Pi "sound is heard once, which
the start of this operation.
In this operation, the system automatically selects
the operation modes ,cooling or fan or heat,
according to the room temperature.
.
It is not possible to operate in dry mode.
Room
temperature
Operation
mode Designated
temperature
Timer
mode Air flow
ABOVE 23OC
BELOW 23 O
C
COOLING
HEAT 23OC
26OCNO
NO
AUTOMATIC
AUTOMATIC
(Cooling only uint
Room temperature Operation
mode Designated
temperature Timer
mode Air flow
BELOW 23O
C FAN 26OCNO AUTOMATIC
at air outlet if all vertical louvers are
right.
mode ,
controller will automatically
Note:
set swing position.
means
changes as
Pi
Pi Pi