Honeywell F111C1073W-3S Bruksanvisning

Honeywell Luftrenare F111C1073W-3S

Läs nedan 📖 manual på svenska för Honeywell F111C1073W-3S (12 sidor) i kategorin Luftrenare. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
PRODUCT DATA
The Honeywell Trademark is used under license from Honeywell International
Inc. by Air-Pure Systems.
Honeywell International Inc. makes no representations or warranties with
respect to this product. 68-0198-2
F111 (Series 1,2,3)
In Ceiling Media Air Cleaner
APPLICATION
The F111 (Series 1,2,3) Ceiling Media Air Cleaner is a media
air cleaner that uses either a single-speed or three-speed
direct drive forward curve blower motor with particle filter.
When equipped with CPZ™ modules (2), gases and odors are
adsorbed from the air passing through the unit. The air
cleaner removes airborne particles such as dust, soot, mold
spores, pollen and some cooking smoke from the air
circulated through the filter.
FEATURES
High Efficiency Particulate Air (HEPA) filter models are
99.97% efficient and the hospital grade particle filter
models are 95% efficient at 0.3 micron particles. Both
models are more efficient on particles smaller and
larger. There is also a 95% ASHRAE model.
Circulates up to 1250 cfm.
Designed to overcome the increase in air flow
resistance normally caused by filter loading.
White or black color cover to complement the ceiling.
CPZ™ module removes up to 95% of the space odors
for up to 24 months.
3-Speed remote wall switch ( 3-speed models only)
READ AND SAVE THESE
INSTRUCTIONS
Contents
Application.........................................................................1
Features ............................................................................1
Specifications ....................................................................2
Ordering Information .........................................................2
Planning the Installation ....................................................3
Installation .........................................................................4
Operation...........................................................................7
Service ..............................................................................8
Parts List ...........................................................................9
Limited Two-Year Warranty ...............................................12
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER
68-0198-2 Release 5-09 2
ORDERING INFORMATION
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Honeywell Commercial Air Products Distributor.
2. Air-Pure Systems
16873 Fish Point Rd. SE
Prior Lake, MN 55372
www.cleanairfacility.com
Phone: (800) 998-1919
Fax: (800) 221-3248
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances. Therefore,
this unit may not exactly match the listed specifica-
tions. Also, this product is tested and calibrated
under closely controlled conditions, and some minor
differences in performance can be expected if those
conditions are changed.
Models: Refer to Table 1 for model descriptions.
Grill Color: White (standard) or Black (add ‘B’ to end of
model number).
Blower/Motor: Single speed (standard) or three speed ( add
‘-3S’ to the end of the model number) direct drive forward
curve.
Dimensions: See Fig. 1 for dimensions.
Table 1. F111 (Series 3) Description.
aFor single-speed and three-speed systems (set to High)
bF111C1061 has a new model number : F111C1012B
To Order F111 with a Black Grill
Replace the ‘W’ with a ‘B’ to any model number in Table 1.
Model Voltage
Efficiency
Gas, V.O.C. and
Odor Control
Modules (2)
Air Volumea
in cfm
(m3/hr)
Particulates at
0.3 Micron
(DOP Test)
V.O.C./Odor
(Most Gases/
Odors First Pass
Average)
F111A1253W-3S 120 Vac, 60 Hz, 8.5A 95% ASHRAE N/A N/A 1250 (2120)
F111A1063W-3S 120 Vac, 60 Hz, 7.2A 99.97% HEPA N/A N/A 950 (1610)
F111C1073W-3S 120 Vac, 60 Hz, 7.5A 95% ASHRAE 85% CPZ™ modules 1150 (1950)
F111C1003W-3S 120 Vac, 60 Hz, 7.0A 99.97% HEPA 85% CPZ™ modules 825 (1400)
F111C1012W-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron 85% CPZ™ modules 1125 (1910)
F111A2253W-3S 230 Vac, 50 Hz, 4.2A 95% ASHRAE N/A N/A 1125 (1910)
F111A2007W-3S 230 Vac, 50 Hz, 3.5A 99.97% HEPA N/A N/A 900 (1530)
F111C2073W-3S 230 Vac, 50 Hz, 4.0A 95% ASHRAE 85% CPZ™ modules 1025 (1740)
F111C2003W-3S 230 Vac, 50 Hz, 3.2A 99.97% HEPA 85% CPZ™ modules 825 (1400)
F111C1053W-3S 230 Vac, 50 Hz, 3.5A 95% at 0.3 micron 85% CPZ™ modules 950 (1610)
F111C1061b
N/A = not applicable.
same as F111C1012B-3S
F111 (SERIES 1,2,3) IN CEILING MEDIA AIR CLEANER
3 68-0198-2
Table 2. F111 Air Volume Specications for 3 Speed Models (Series 3).
aSame for Single Speed Models (Series 1 & 2).
.
Fig. 1. Approximate dimensions of F111
(Series 1,2,3) in in. (mm).
Installation Weight:
Approximately 115 lb to 155 lb (kg) depending on the filter
configuration. Refer to Table 3.
Table 3. Sorbent Module Weight.
Sound Level at 3.3 ft (1m):
Low speed: 53 dBA (3 speed models only).
Medium speed: 57 dBA (3 speed models only)
High speed: 61 dBA.
Grille Type: Perforated metal.
Mounting: Recesses into opening on the ceiling.
Approvals:
Underwriters Laboratories Inc.: Listed.
Canadian Standards Association: Listed.
Accessories:
Black Color Grill
Remote 3-Speed Wall Switch
Replacement Parts See Parts List, Table 5.
PLANNING THE INSTALLATION
The number of F111 (series 1,2,3) air cleaners that are needed
is determined by taking into account the number of occupants
and the volume of the space. Type of contamination, outdoor
air quality and use of the area are also factors. Refer to Table
3 for general guidelines when determining how many air
cleaners are needed.
EXAMPLE: One air cleaner can provide 2.5 air changes per
hour in a 24,000 cubic feet (720 cubic meters) no
smoking area. Table 3 suggests two air cleaners
for a 24,000 cubic feet area because most areas
have contaminants that require more units to
provide quality air.
If any questions should arise concerning determining the
number of air cleaners needed for an area, consult your
distributor or local Honeywell Commercial Air Cleaner
Distributor.
Table 4. Determining the Minimum Number of
Air Cleaners Needed for a Space.
Model Voltage
Particulates at
0.3 Micron
(DOP Test)
Gas, V.O.C. and
Odor Control
Modules (2)
Higha
in cfm
(m3/hr)
Medium
in cfm
(m3/hr)
Low
in cfm
(m3/hr)
F111A1253W-3S 120 Vac, 60 Hz, 8.5A 95% ASHRAE N/A 1250 (2120) 800 (1360) 450 (760)
F111A1063W-3S 120 Vac, 60 Hz, 7.2A 99.97% HEPA N/A 950 (1610) 775 (1310) 450 (760)
F111C1073W-3S 120 Vac, 60 Hz, 7.5A 95% ASHRAE CPZ™ modules 1150 (1950) 825 (1400) 450 (760)
F111C1003W-3S 120 Vac, 60 Hz, 7.0A 99.97% HEPA CPZ™ modules 825 (1400) 700 (1190) 450 (760)
F111C1012W-3S 120 Vac, 60 Hz, 8.0A 95% at 0.3 micron CPZ™ modules 1125 (1910) 825 (1400) 450 (760)
F111A2253W-3S 230 Vac, 50 Hz, 4.2A 95% ASHRAE N/A 1125 (1910) 700 (1190) 475 (810)
F111A2007W-3S 230 Vac, 50 Hz, 3.5A 99.97% HEPA N/A 900 (1530) 600 (1020) 400 (680)
F111C2073W-3S 230 Vac, 50 Hz, 4.0A 95% ASHRAE CPZ™ modules 1025 (1740) 675 (1150) 450 (760)
F111C2003W-3S 230 Vac, 50 Hz, 3.2A 99.97% HEPA CPZ™ modules 825 (1400) 550 (930) 375 (640)
F111C1053W-3S 230 Vac, 50 Hz, 3.5A 95% at 0.3 micron CPZ™ modules 950 (1610) 625 (1060) 425 (720)
Media Weight in lb (kg)
CPZ™ modules (2) 43 (20)
22-1/2 (572)
24 (610)
3/8 X 16
INTERNAL
THREAD (4)
46-3/4 (1187)
48 (1219)
17-1/4
(438)
4-1/2
(114)
TOP VIEW
POWER CONNECTION
POINT
CEILING
LINE
M11996A
Space Volume
(L x W x H) in Cubic
Feet (Cubic Meter)
Number of
Persons Present
Minimum
Number of Air
Cleaners
12000 to 18000
(360 to 540)
30 to 60 1
18001 to 35000
(540 to 1050)
61 to 90 2

Produktspecifikationer

Varumärke: Honeywell
Kategori: Luftrenare
Modell: F111C1073W-3S
Enhetsplacering: Vrijstaand
Typ av operation: Draaiknop
Färg på produkten: Wit
Dörrgångjärn: Links
Inbyggd display: Ja
Bredd: 595 mm
Djup: 458 mm
Höjd: 845 mm
Typ av laddare: Voorbelading
Dörrfärg: Wit
Trummaterial: Roestvrijstaal
Energie-efficiëntieklasse: D
Tvätt energiförbrukning: 0.68 kWu
Vattenförbrukning per cykel: 41 l
Centrifuger läkemedelsklass: B
Ljudnivå (tvätt): - dB
Maximal centrifugeringshastighet: 1200 RPM
Nuvarande: 10 A
Bulleremissionsklass: B
Ljudnivå under centrifugering: 76 dB
Cykeltid (max): 208 min
Antal tvättprogram: 15
Energiförbrukning per 100 cykler: 68 kWu
Efter typ: Gehard glas
Öppen dörr: Opening aan zijkant
Nominell kapacitet: 7 kg
Rengör trumma: Ja
AC-ingångsspänning: 220 - 240 V
AC-ingångsfrekvens: 50 Hz
Energieffektivitetsskala: A tot G
Wasprogramma's: Baby care, Blouse/shirt, Colour, Cotton, Cottons 20°C, Eco, Mix, Quick 15min, Rinse & spin, Sport, Wool

Behöver du hjälp?

Om du behöver hjälp med Honeywell F111C1073W-3S ställ en fråga nedan och andra användare kommer att svara dig




Luftrenare Honeywell Manualer

Luftrenare Manualer

Nyaste Luftrenare Manualer