Honeywell HPA-245 Bruksanvisning

Läs nedan 📖 manual på svenska för Honeywell HPA-245 (32 sidor) i kategorin Luftrenare. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/32
DOCTOR’S CHOICE
ALLERGEN REMOVER
For Model Series HPA-24X
IMPORTANT
SAFETY
INSTRUCTIONS
READ AND SAVE THESE SAFETY
INSTRUCTIONS BEFORE USING THIS
AIR PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the
air purifier.
2. Place air purifier where it is not easily
knocked over by persons in the household.
3. Always turn the air purifier controls to the
OFF position and unplug from the wall
outlet when not in use.
4. To disconnect the air purifier, press the
Power button ( ) to turn the unit off, grip
the plug and pull it from the wall outlet.
Never pull by the cord.
5. Do not use any product with a damaged
cord or plug or if product malfunctions, is
dropped or damaged in any manner. Keep
the cord away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and
do not cover with throw rugs. Arrange
cord such that it will not be tripped over.
9. Do not use air cleaner where combustible
gases, vapors or an oxygen rich
environment are present.
10. Do not expose the air purifier to rain, or
use near water, in a bathroom, laundry
area or other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter
ventilation or exhaust opening as this may
cause electric shock or damage to the air
purifier. Do not block air outlets or intakes.
13. Locate air purifier near the outlet and
avoid using an extension cord.
14. This appliance has a polarized plug (one
blade is wider than the other). To reduce
the risk of shock, this plug is intended to
fit only one way in a polarized outlet. If the
plug does not fit fully in the outlet, reverse
the plug. If it still does not fit, contact a
qualified electrician.
DO NOT attempt to defeat this safety
feature.
15. A loose fit between the AC outlet
(receptacle) and plug may cause
overheating and a distortion of the plug.
Contact a qualified electrician to replace
loose or worn outlet.
16. Do not sit, stand or place heavy objects on
the air purifier.
The Honeywell trademark is used by Kaz USA, Inc. under license from Honeywell International Inc.
Honeywell International Inc. makes no representation or warranties with respect to this product.
2
ODOR CONTROL
This air purifier includes a special odor absorbing pre-filter(s)
PlusPlus
packed in the product box. In order
to enjoy the benefits of enhanced odor control, replace the washable pre-filter that is already in the air
purifier with the odor absorbing pre-filter
PlusPlus
.
For optimal performance, the pre-filter(s) is(are) wrapped in plastic to keep them fresh. Pre-filter
replacement timing will be approximately 3 months, depending on use.
You can purchase replacement
PlusPlus
pre-filters from the store where you purchased your air purifier or visit
www.replacementfilters.com. If you have any questions, contact Kaz Consumer Services at 1-800-477-0457.
YOUR AIR PURIFIER
HOW YOUR AIR PURIFIER WORKS
Control Panel
True
HEPA
filters
(2)
N
Washable
Pre-filter (1)
OR
Optional
Odor
Reducing
Pre-filter
PlusPlus
Rear Grille
17. Disconnect power supply before servicing.
18. SAVE THESE INSTRUCTIONS.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
The sealed UV bulbs contain a small
amount of mercury. Dispose of these items
at household hazardous waste collection
sites only. If the UV bulb breaks, do not
vacuum or handle with your bare hands.
This model air purifier incorporates a 2-stage cleaning
system to help clean the air that passes through the filter
in the unit (Fig. 1).
Stage 1: Odor Absorbing Pre-Filter
Stage 2: True HEPA Filter that captures
particles as small as 0.3 microns or larger
2
Filter(s)
Fig. 1
OPERATION
Powering Up: (Fig. 3)
Plug the air purifier into a grounded, working outlet. Once the unit
is plugged in, the back-lit Power Button icon ( ) will blink for
12 seconds indicating the unit is ready for operation.
When the Power Button is pressed the following will take place:
° The LCD display and buttons will light up. The Oscillation, On/off,
Timer, and Timer +/– button lights will turn off after 3 seconds.
The LCD light will turn off after 8 seconds if no buttons are
pressed.
° The UV feature turns on.
° The air purifier will operate at a medium cleaning power level for
a few seconds and then automatically change to a low level.
° The continuous Run display turns on and rotates.
° The filter status display turns on. (Note: The 1st segment is
always filled in. Additional segments will fill in as the filter
gets dirty.)
° The “filtersand “UV Bulblights will be green. (Note: if they
are red, this indicates that the filters must be cleaned or UV
bulbs replaced.)
INSTALL HEPA FILTERS
The True-HEPA Filters are supplied within the air purifier. They are wrapped to ensure
purity, and are labeled to help identify the proper replacement filter. (Type
N
).
• Make sure the air purifier is turn off and unplugged.
• Remove the rear grille by pressing the notch on the top of the rear grille and
pulling the grille towards you (Fig. 2).
• Remove the filters by gently pushing along the edge of the filter frame and
pulling it forward. Repeat for the second filter.
• Remove the protective wrap from the filters.
• Place the filters back into the air purifier housing and snap the rear grille back
into place.
NOTE: The pre-filter needs to be in position along the rear grille before snapping the grille back into place.
NOTE: The Top filter must be in place in order for the unit to operate.
Fig. 2
SET-UP
• Select a firm, level and flat location. For proper airflow, locate the unit at least 3 feet (1 M) from any wall
or furniture.
• When operating, large volumes of air are drawn toward the air purifier. Surrounding areas should be
cleaned and/or vacuumed frequently to prevent build-up of dust and other contaminates. If the unit is
placed on a light colored carpet, a small mat or rug should be used underneath to prevent permanent
staining. This is especially important in homes with contamination from smoking, fireplaces or where
candles are burned.
• Ensure the exit grille (front of the unit) faces away from the closest wall or furniture.
• Ensure no grilles are blocked.
Fig. 3
UV on/off
button
Filter
button
UV bulb
reset button
Power button
Cleaning power
+/- button
Oscillation
button
Timer
+/– button
Timer on/off
button
LCD display
Filter
Status

Produktspecifikationer

Varumärke: Honeywell
Kategori: Luftrenare
Modell: HPA-245

Behöver du hjälp?

Om du behöver hjälp med Honeywell HPA-245 ställ en fråga nedan och andra användare kommer att svara dig




Luftrenare Honeywell Manualer

Luftrenare Manualer

Nyaste Luftrenare Manualer