Instruction Manual
Issued: 9-23-2016
hoshizakiamerica.com
Low-Profile Modular Crescent Cuber
Models
KML-325MAJ, MWJ
KML-500MAJ, MWJ
KML-700MAJ, MWJ, MRJ
2
WARNING
Only qualied service technicians should install and service the appliance. To
obtain the name and phone number of your local Hoshizaki Certied Service
Representative, visit www.hoshizaki.com. No installation or service should be
undertaken until the technician has thoroughly read this Instruction Manual.
Likewise, the owner/manager should not proceed to operate the appliance until the
installer has instructed them on its proper operation. Failure to install, operate, and
maintain the appliance in accordance with this manual will adversely affect safety,
performance, component life, and warranty coverage and may result in costly water
damage. Proper installation is the responsibility of the installer. Product failure or
property damage due to improper installation is not covered under warranty.
Hoshizaki provides this manual primarily to assist qualied service technicians in the
installation, maintenance, and service of the appliance.
Should the reader have any questions or concerns which have not been satisfactorily
addressed, please call, send an e-mail message, or write to the Hoshizaki Technical
Support Department for assistance.
Phone: 1-800-233-1940; (770) 487-2331
Fax: 1-800-843-1056; (770) 487-3360
E-mail: techsupport@hoshizaki.com
618 Highway 74 South
Peachtree City, GA 30269
Attn: Hoshizaki Technical Support Department
NOTE: To expedite assistance, all correspondence/communication MUST include the
following information:
• Model Number
• Serial Number
• Complete and detailed explanation of the problem.
3
CONTENTS
Important Safety Information 4 .................................................................................................
I. Specications 6 ......................................................................................................................
A. Electrical and Refrigerant Data 6 .....................................................................................
1. KML-325M_J 6 ............................................................................................................
2. KML-500M_J 6 ...........................................................................................................
3. KML-700M_J 7 ...........................................................................................................
B. Dimensions/Connections 8 ..............................................................................................
1. Air-Cooled Models (MAJ) 8 .........................................................................................
2. Water-Cooled Models (MWJ) 9 ...................................................................................
3. Remote Models (MRJ) ........................................................................................... 10
4. Remote Condenser Unit URC-9F (use with KML-700MRJ) ....................................11
II. Installation and Operating Instructions ............................................................................ 12
A. Location ...................................................................................................................... 12
B. Checks Before Installation ........................................................................................... 12
C. How to Remove Panels ............................................................................................... 13
D. Setup ........................................................................................................................... 14
E. Electrical Connection .................................................................................................. 15
F. Water Supply and Drain Connections .......................................................................... 16
1. Icemaker ................................................................................................................ 17
2. Water-Cooled Condenser....................................................................................... 18
a) KML-325/500MWJ .............................................................................................. 18
b) KML-700MWJ 20 .....................................................................................................
G. Installation of Remote Condenser Unit 22 .......................................................................
1. Location 22 .................................................................................................................
2. Checks Before Installation 23 .....................................................................................
3. Setup 23 .....................................................................................................................
4. Line Set Size and Refrigerant Charge 23 ...................................................................
5. Line Set Installation 24 ...............................................................................................
6. Electrical Connection 27 .............................................................................................
7. Stacking Remote Condenser Unit 28 ..........................................................................
H. Final Checklist 29 .............................................................................................................
I. Startup 30 ..........................................................................................................................
III. Maintenance 31 ...................................................................................................................
A. Maintenance Schedule 31 ................................................................................................
1. Cleaning Procedure 32 ................................................................................................
2. Sanitizing Procedure - Following Cleaning Procedure 34 ...........................................
IV. Preparing the Icemaker for Periods of Non-Use 35 .............................................................
V. Disposal 37 ...........................................................................................................................
IMPORTANT
This manual should be read carefully before the appliance is installed and operated.
Read the warnings and guidelines contained in this manual carefully as they
provide essential information for the continued safe use and maintenance of the
appliance. Retain this manual for any further reference that may be necessary.

Produktspecifikationer

Varumärke: Hoshizaki
Kategori: Ismaskin
Modell: KML-500MAJ

Behöver du hjälp?

Om du behöver hjälp med Hoshizaki KML-500MAJ ställ en fråga nedan och andra användare kommer att svara dig




Ismaskin Hoshizaki Manualer

Ismaskin Manualer

Nyaste Ismaskin Manualer