Installation instructions
Aseptoflex Vario adapter
with O-ring / PEEK sealing ring
E332xx
E333xx
704965/01 02/2011
UK
2
1 Installation sensor - adapter
C
B
A
Grease the sensor thread with
paste (A).
The paste must be suitable and ap-
proved for the application and com-
patible with the elastomers used.
Place the sealing ring (B) in the
groove (C) of the sensor.
Screw the sensor into the adapter
until it is hand-tight. When doing
so, avoid mechanical effects on the
sealing areas, the hygienic area and
the pressure measuring cell.
D
Clamp the sensor + adapter into a
clamping device (D). Tighten the
clamping device only slightly so that
the adapter does not warp.
Tighten the sensor using a spanner
until you can feel the end stop (this
corresponds to a maximum tighten-
ing torque of 35 Nm). Note: Further
tightening may affect the sealing
effect.
3
UK
The adapter is supplied with an EPDM O-ring. More sealing rings are available as
accessories:
FKM O-ring, order no. E30123.
PEEK sealing ring, order no. E30124.
Use a new adapter when changing from a PEEK seal to O-ring sealing.
2 Mounting to the process connection
Fix the sensor + adapter are fixed to the process connection using a fixing ele-
ment (coupling nut, clamp flange, etc.).
If it is not possible to slide the fixing element down over the top of the unit: slide
it up over the bottom of the unit before the adapter is mounted.
Use in hygienic areas to EHEDG:
Make sure that the sensors are integrated into the system in accord-
ance with EHEDG.