Installation Instructions
Universal process adapter RD52
E33340
704966/01 02/2011
UK
2
B
C
A
Grease thread and sealing (B) of the
coupling nut (C) with paste (A).
The paste must be suitable and ap-
proved for the application and compat-
ible with the elastomers used.
D
Slip the coupling nut onto the sensor (D)
from the bottom.
F
E
A
D
Grease the sensor thread with the paste
(A) (see above ).
Place the sealing ring (E) in the groove
(F) of the sensor.
The adapter is supplied with an EPDM
O-ring. More sealing rings are available as
accessories:
FKM O-ring, order no. E30123.
PEEK sealing ring, order no. E30124.
Use a new adapter when changing from a
PEEK seal to O-ring sealing.
3
UK
G
H
Screw the sensor into the adapter (G)
until it is hand-tight. When doing so,
avoid mechanical effects on the sealing
areas, the hygienic area and the pres-
sure measuring cell..
Make sure that the O-ring (H) is correctly
positioned.
I
Clamp the sensor + adapter into a
lamping device (I). Tighten the clamping
device only slightly so that the adapter
does not warp.
Tighten the sensor using a spanner until
you can feel the end stop (this corre-
sponds to a maximum tightening torque
of 35 Nm). Note: Further tightening may
affect the sealing effect.
Insert the unit in a universal process connection RD52.
Tighten the coupling nut.