IFM IF5766 Bruksanvisning

Läs nedan 📖 manual på svenska för IFM IF5766 (1 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/1
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen • Germany • http://www.ifm.com • e-mail:info@ifm.com
UK
80011315 / 00 05 / 2014
Mounting Instructions
Flush mountable tubular switches / CSA Div. 2
Flush mountable switches can be mounted so that the ac-
tive face is flush with a metal surface. Any metal in front
of the switch should be kept at a distance of three times
the nominal sensing range.
s = nominal sensing range
b = maximum thread length
M8 - 8 mm, M12 - 8 mm
M18 - 8 mm, M30 - 16 mm
3xs
b
Two flat nuts are provided to hold the installed switch in
place.
When mounting tubular switches opposite each other, the spacing distance
shown here should be maintained.
Sr = nominal sensing range
8 x Sr
active face
When mounting tubular switches next to each other, the spacing distance
shown here should be maintained.
D = switch diameter
D
DD
active face
active face
CSA for Hazardous Locations
When wired in accordance with CEC and this mounting instructions.
Class I, Div. 2, Groups A, B, C and D
Class II, Div. 2, Groups E, F and G
Class III, T4
Enclosure: Type 4/4x
Temp. range: -13° to 176°F (-25° to 80°C)
ELECTRICAL
DO NOT operate an incandescent light bulb as a load.
The current inrush when the bulb is cold can cause a
current overload.
DO NOT operate a proximity sensor directly from a
voltage supply without a load. This is a short circuit and
can cause damage. Note: insert a miniature fuse accor-
ding to the technical data sheet, if specified.
Concerning Safety... ifm efector makes every effort to build a de-
pendable product, but every product will eventually fail. Therefore,
your equipment must be designed to prevent property damage
and personal injury if our products fail. ifm efector proximity
switches are not designed to be used as stand-alone devices to
protect or guard human life or limb.
WARNING
Explosion Hazard – substitution of components may impair suitability
of Class 1, Div. 2. Do not disconnect while circuit is live unless area is
known to be non-hazardous.
AVERTISSEMENT
Risque d'explosion - La Substitution de composants peut rendre ce
matérielle inacceptable pour les emplacements de classe I division 2.
Ne pas débrancher tant que le circuit est sous tensions, à moins qu'il
ne s'agisse d'un emplacement non dangereux.
CAUTION
Use only ifm efector conduit adapters (U30029, U30030, U30031) or
other CSA ceritifed conduit adapters.
ATTENTION
Utiliser uniquement les adaptateurs tube d'ifm efector (U30029,
U30030, U30031) ou d'autres adaptateurs tube certifiés par CSA.

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: IF5766

Behöver du hjälp?

Om du behöver hjälp med IFM IF5766 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad IFM Manualer

IFM

IFM OT5012 Bruksanvisning

27 Oktober 2024
IFM

IFM SUH201 Bruksanvisning

26 Oktober 2024
IFM

IFM PI1003 Bruksanvisning

26 Oktober 2024
IFM

IFM AC1254 Bruksanvisning

21 Oktober 2024
IFM

IFM EVW027 Bruksanvisning

21 Oktober 2024
IFM

IFM EVC132 Bruksanvisning

20 Oktober 2024
IFM

IFM PT2400 Bruksanvisning

20 Oktober 2024
IFM

IFM O2D532 Bruksanvisning

20 Oktober 2024
IFM

IFM PA3027 Bruksanvisning

20 Oktober 2024
IFM

IFM TW2001 Bruksanvisning

18 Oktober 2024

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer