Installation instructions
Inclination sensor JN
JN2200
JN2201
80237500/00 04/2016
UK
2
1 Functions and features
The 2-axis analogue/binary inclination sensor with IO-Link interface enables angle
levelling and position detection of machines and installations.
Typical applications are, for example, the position detection of access platforms,
levelling of mobile cranes or monitoring of wind turbines.
2-axis inclination sensors with a measuring range of:
JN2200: ±180°
JN2201: ±45°
2 Symbols used
Instruction
Important note
Non-compliance may result in malfunction or interference.
3 Installation
Disconnect from power before installation.
3.1 Fixing
Fasten the device using 4 M5 screws on a flat surface.
Screw material: steel or stainless steel.
3.2 Mounting surface
The housing must not be exposed to any torsional forces or mechanical stress.
Use compensating elements if there is no flat mounting surface available.
4 Electrical connection
The unit must be connected by a qualified electrician.
The national and international regulations for the installation of electrical equipment
must be adhered to.
Disconnect the installation from power and connect the unit.
3
UK
The inclination sensors are fitted with two round 4-pole M12 connectors (class A)
in accordance with IEC 60947-5-2. The M12 connectors are mechanically A-coded
in accordance with IEC 61076-2-101.
 
1: L+ 24 V DC (+Ub-D)
2: OUT2 switching output 2
3: L- mass (GND)
4: OUT1 switching output 1 or IO-Link
M12 connector (left)
 
1: L+ 24 V DC (+Ub-A)
2: A2 analogue output 2
3: L- mass (GND)
4: A1 analogue output 1
M12 connector (right)
5 IO-Link
General information
This unit has an IO-Link communication interface (via pin 4) which requires an IO-
Link-capable module (IO-Link master) for operation.
The IO-Link interface enables direct access to process and diagnostic data.
Communication via a point-to-point connection is possible with USB adapter cable.
You will find the IODDs and parameter setting tools necessary for the configuration
of the IO-Link unit at www.ifm.com.
6 Technical data, approvals/standards
Detailed manuals, technical data, EC declaration of conformity, approvals and
further information can be found at www.ifm.com.
7 Maintenance, repair and disposal
The unit is maintenance-free.
Dispose of the unit in accordance with the national environmental regulations.

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: JN2200

Behöver du hjälp?

Om du behöver hjälp med IFM JN2200 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad IFM Manualer

IFM

IFM OT5012 Bruksanvisning

27 Oktober 2024
IFM

IFM SUH201 Bruksanvisning

26 Oktober 2024
IFM

IFM PI1003 Bruksanvisning

26 Oktober 2024
IFM

IFM AC1254 Bruksanvisning

21 Oktober 2024
IFM

IFM EVW027 Bruksanvisning

21 Oktober 2024
IFM

IFM EVC132 Bruksanvisning

20 Oktober 2024
IFM

IFM PT2400 Bruksanvisning

20 Oktober 2024
IFM

IFM O2D532 Bruksanvisning

20 Oktober 2024
IFM

IFM PA3027 Bruksanvisning

20 Oktober 2024
IFM

IFM TW2001 Bruksanvisning

18 Oktober 2024

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer