Installation Instructions
Electronic pressure sensor
PA32xx
704091 / 01 06 / 2019
UK
2
1 Symbols used
Instruction
Important note
Non-compliance can result in malfunction or interference.
Information
Supplementary note.
2 Safety instructions
The device described is a subcomponent for integration into a system.
- The manufacturer of the system is responsible for the safety of the system.
- The system manufacturer undertakes to perform a risk assessment and to
create a documentation in accordance with legal and normative requirements
to be provided to the operator and user of the system. This documentation
must contain all necessary information and safety instructions for the opera-
tor, the user and, if applicable, for any service personnel authorised by the
manufacturer of the system.
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and environ-
mental conditions without any restrictions.
Only use the product for its intended purpose (→ Functions and features).
Only use the product for permissible media (→ Technical data).
Inhalt
1 Symbols used 2 ......................................................................................................
2 Safety instructions 2 ...............................................................................................
3 Function and features ..........................................................................................3
3.1 Applications ...................................................................................................4
4 Installation............................................................................................................4
5 Electrical connection 5 ............................................................................................
3
UK
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the unit
must be carried out by qualified personnel authorised by the machine operator.
Protect units and cables against damage.
For units with cULus approval and the scope of validity cULus:
The device shall be supplied from an isolating transformer having a secondary
Listed fuse rated as noted in the following table.
Overcurrent protection
Control-circuit wire size Maximum protective device rating
Ampere
AWG (mm2)
26 1(0.13)
24 2(0.20)
22 3(0.32)
20 5(0.52)
18 7(0.82)
16 10(1.3)
The Sensor shall be connected only by using any R/C (CYJV2) cord, having
suitable ratings.
3 Function and features
The pressure sensor detects the system pressure and converts it into an analog
output signal.
4 ... 20 mA

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: PA3228

Behöver du hjälp?

Om du behöver hjälp med IFM PA3228 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad IFM Manualer

IFM

IFM OT5012 Bruksanvisning

27 Oktober 2024
IFM

IFM SUH201 Bruksanvisning

26 Oktober 2024
IFM

IFM PI1003 Bruksanvisning

26 Oktober 2024
IFM

IFM AC1254 Bruksanvisning

21 Oktober 2024
IFM

IFM EVW027 Bruksanvisning

21 Oktober 2024
IFM

IFM EVC132 Bruksanvisning

20 Oktober 2024
IFM

IFM PT2400 Bruksanvisning

20 Oktober 2024
IFM

IFM O2D532 Bruksanvisning

20 Oktober 2024
IFM

IFM PA3027 Bruksanvisning

20 Oktober 2024
IFM

IFM TW2001 Bruksanvisning

18 Oktober 2024

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer