Operating instructions
Ultrasonic diffuse-reflection sensor
without IO-Link
UGT20x
UGT21x
UGT50x
UGT52x
80237715 / 00 02 / 2019
UK
2
1 Safety instructions
Read this document before setting up the product and keep it during the entire
service life.
The product must be suitable for the corresponding applications and environ-
mental conditions without any restrictions.
Only use the product for its intended purpose .(→ 2 Functions and features)
If the operating instructions or the technical data are not adhered to, personal
injury and/or damage to property may occur.
The manufacturer assumes no liability or warranty for any consequences
caused by tampering with the product or incorrect use by the operator.
Installation, electrical connection, set-up, operation and maintenance of the
product must be carried out by qualified personnel authorised by the machine
operator.
Protect units and cables against damage.
2 Functions and features
Ultrasonic sensor for monitoring levels and detecting objects.
3 Installation
1
2
Secure the unit to a bracket.
1: Status LED (yellow), setting aid and
output indication
2: Echo LED (green), is on when object or
background is detected
Sound-absorbing surfaces have a negative effect on a reliable function.
Technical data sheet): Consider the dead zone (
No object detection in the dead zone.
3
UK
For units with metal housing (according to UL 508):
Observe a minimum distance of 12.7 mm between the sensor and non-
insulated live parts.
For further information please refer to www.ifm.com
General information about installation and operation.
4 Electrical connection
Disconnect power.
Connect unit (depending on the type selected):
BK: black
BN: brown
BU: blue
WH: white
L+
L
1
4
3
OUT
2WH
BN
BK
BU
Teach
L+
L
1
4
3
OUT
2WH
BN
BK
BU
Teach
Units with switching output
• OUT: switching output
• Teach: programming wire
Units with analogue output
• OUT: analogue output
• Teach: programming wire
Colours to DIN EN 60947-5-2
5 Settings
The unit and the parameters are set via the teach programming wire
(→ 5.1).
5.1 Wire teach
Switching output:
Teach with L+ (PNP)
Switching output:
Teach with L- (NPN)
Analogue output:
Teach with L -
L+
L
1
4
3
OUT
Teach
2WH
BN
BK
BU
L+
L
1
4
3
OUT
Teach
2WH
BN
BK
BU
L+
L
1
4
3
OUT
2WH
BN
BK
BU
Teach
If programming has not been completed successfully, the unit returns to
the previous setting.

Produktspecifikationer

Varumärke: IFM
Kategori: Inte kategoriserad
Modell: UGT502

Behöver du hjälp?

Om du behöver hjälp med IFM UGT502 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad IFM Manualer

IFM

IFM OT5012 Bruksanvisning

27 Oktober 2024
IFM

IFM SUH201 Bruksanvisning

26 Oktober 2024
IFM

IFM PI1003 Bruksanvisning

26 Oktober 2024
IFM

IFM AC1254 Bruksanvisning

21 Oktober 2024
IFM

IFM EVW027 Bruksanvisning

21 Oktober 2024
IFM

IFM EVC132 Bruksanvisning

20 Oktober 2024
IFM

IFM PT2400 Bruksanvisning

20 Oktober 2024
IFM

IFM O2D532 Bruksanvisning

20 Oktober 2024
IFM

IFM PA3027 Bruksanvisning

20 Oktober 2024
IFM

IFM TW2001 Bruksanvisning

18 Oktober 2024

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer