Room temperature controller
26.06.20201 / 50024091005
Room temperature controller
Ref.-no.: TR .. 231 ..
TR .. 241 ..
TR .. 236 ..
TR .. 246 ..
Operating instructions
1 Safety instructions
Electrical devices may only be mounted and connected by electrically skilled persons.
Serious injuries, re or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or load.
A relative air humidity of max. 95% may not be exceeded. Avoid any moisture condensation.
These instructions are an integral part of the product, and must remain with the end customer.
2 Structure of the device
Fig. 1: Geräteaufbau
(1) Insert
(2) Frame
(3) Cover
(4) Rocker
(5) Screw
(6) Setting knob
3 Function
Intended purpose
The room temperature controller is used to regulate the temperature in closed rooms such as ats, schools, function
suites, workshops, etc.
Product characteristics
Neutral conductor required
TR 231 U / TR 241 U:
- Separate terminal for temperature reduction of 5 K (e.g. during night time)
- ON/OFF switch with status LED
- When set temperature is reached the contact opens up.
TR 236 U / TR 246 U:
- No OFF-position
- Without switch and control LED
- When set temperature is reached the NO/NC contact switches over.
2
5
3
4
1
6
GB
Room temperature controller
26.06.20202 / 50024091005
4 Information for electrically skilled persons
Installation and electrical connection
DANGER
Electric shock from touching live parts in the installation environment.
An electric shock can be fatal.
Before working on the device, disconnect the power and cover live parts in the area.
- Mount the room temperature controller on an internal wall opposite the heat source if possible.
- Do not mount the room temperature controller on outside walls.
- Avoid draughts from windows and doors.
- Ensure that the normal air circulation in the room reaches the controller without any obstacles.
- External heat sources inuence the accuracy of the controller. Avoid direct sunlight and do not place heat-emitting
devices in the vicinity of the room temperature controller (heaters, lamps, etc.).
- Dimmers also generate heat.
If a controller is installed in a common switch frame with a dimmer, the distance between them should be as great
as possible. When arranging them vertically, the controller must be installed underneath the dimmer.
Connection
Fig. 2: TR 231 U
Fig. 3: TR 241 U
Room temperature controller
26.06.20203 / 50024091005
Fig. 4: TR 236 U
Fig. 5: TR 246 U
Carry out the electrical connection according to the respective wiring diagram.
iEnsure that the neutral conductor N is connected to terminal N. Considerable uctuations in temperature may
otherwise occur.
Conductor cross-section: 1 to 2.5 mm² solid conductor
Symbols used in the wiring diagram
L = L conductor
N = N-conductor
AC1 = 24 V power supply
AC2
= Connection for clock signal to reduce temperature
= Heating
= Cooling
RF = Resistor for thermal feedback
TA = Resistor for night reduction of room temperature
Installation
Mount room temperature controller in a switch box in accordance with DIN 49073.
Mounting height: approx. 1.5 m above the oor
Clip the rocker (4) on the switch in the ush insert. (g. 1)
Place the center plate together with the frame on the ush insert. The center plate must snap in place in the top
left of the housing base.
Tighten the screw (5). (g. 1)
Clip on the setting knob (6). (g. 1)

Produktspecifikationer

Varumärke: Jung
Kategori: Temperaturregulator
Modell: TRSL2
Färg på produkten: Black, White
Vikt: 2900 g
Bredd: 165 mm
Djup: 165 mm
Höjd: 274 mm
Snäll: IP-beveiligingscamera
Husmaterial: Aluminium
Internationell säkerhetskod (IP): IP66
Vormfaktor: Dome
Autofokus: Ja
Placeringsstöd: Binnen & buiten
Anslutningsteknik: Bedraad
Ethernet LAN: Ja
Monteringsmetod: Muur
Videolägen som stöds: 720p
Maximal upplösning: 1280 x 720 Pixels
Totalt antal megapixlar: - MP
Videokomprimeringsformat: AVC, H.264, M-JPEG, MPEG4
Typ av strömkälla: AC, PoE
Minimal belysning: 0.01 Lux
Antal kameror: 1
Integrerad minneskortläsare: Ja
Kompatibla minneskort: SD, SDHC, SDXC
Video rörelsedetektering: Ja
HTTPS-kryptering: Ja
Zoomkapacitet: Ja
Antal Ethernet LAN (RJ-45)-portar: 1
Brännvidd: 4.3 - 129 mm
Lösenordsskydd: Ja
Strömförbrukning (max): 51 W
Optisk sensorstorlek: 1/2.8 "
Bildstabilisator: Ja
Bildsensortyp: CMOS
Digital zoom: 12 x
Optisk zoom: 30 x
Kamerans slutartid: 1/60000 - 2 s
Internminne: 512 MB
Grafikupplösningar som stöds: 320 x 180,1280 x 720 (HD 720)
Nätverksstandard: IEEE 802.1x, IEEE 802.3at
Förvaringstemperatur: -40 - 70 °C
Max 30 bilder per sekund: 60 fps
Nätverksprotokoll som stöds: IPv4, IPv6 USGv6, HTTP, HTTPS , SSL/TLS , QoS Layer 3 DiffServ, FTP, CIFS/SMB, SMTP, Bonjour, UPnPTM, SNMP v1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, RTSP, RTP, SRTP, SFTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS, SSH, NTCIP
Förvaringsfuktighet: 5 - 95 procent
IP-adressfilter: Ja
Progressiv skanning: Ja
Flashminne: 256 MB
Ethernet-gränssnittstyp: Fast Ethernet
Språk som stöds: CHI (SIMPL), CHI (TR), DEU, ENG, ESP, FRE, ITA, JPN, KOR, POR, RUS
Quality of Service (QoS): Ja
Jag kodar: IK10
PTZ-kontroll: Ja
Panoreringsintervall: 0 - 360 °
Antal linser: 1
Maximalt antal bländare: 4.7
Minsta bländartal: 1.6
Styr kamerapanorering: Ja
Kameralutningsfunktion: Ja
Svänghastighet: 500 °/sec
Pannhastighet: 700 °/sec
Strömningsmetod: Multicast
Antal sensorer: 1
Videostreaming: Ja
Infrarött (IR) termineringsfilter: Ja
Bakgrundsljuskompensation: Ja
Förinställda punkter: Ja
Antal språk: 11
Bithastighetskontroll: Variabele bitsnelheid (VBR)
Justering av bildkvalitet: Brightness, Colour depth, Sharpness
Wide Dynamic Range (WDR): Ja
Turnéinspelning: Ja
AC-ingångsspänning: 100-240 V
Strömförbrukning (typiskt): 11 W
Drifttemperatur (TT): -20 - 50 °C
Relativ luftfuktighet i drift (VV): 10 - 100 procent
Tiltvinkelområde: -90 - 20 °
Harmoniserad systemkod (HS): 85258900
Mask privat zon: Ja
Linsens betraktningsvinkel, horisontell: 66.7 °
Typ av varningsmeddelande: E-mail
Linsens betraktningsvinkel, vertikal: 39.5 °
Automatisk spårning: Ja
Textoverlay: Ja

Behöver du hjälp?

Om du behöver hjälp med Jung TRSL2 ställ en fråga nedan och andra användare kommer att svara dig




Temperaturregulator Jung Manualer

Temperaturregulator Manualer

Nyaste Temperaturregulator Manualer