Kern ORA 1GG Bruksanvisning
Kern
Mätutrustning
ORA 1GG
Läs nedan 📖 manual på svenska för Kern ORA 1GG (2 sidor) i kategorin Mätutrustning. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2

1
6
5
3
2
4
CONTENT S
1 Technical data.................................................................................................1
2 Description......................................................................................................2
3 General information 3 .......................................................................................
3.1 Intended use 3 ...................................................................................................
3.2 Warranty..........................................................................................................3
4 Basic safety information 4 ...............................................................................
4.1 Follow the instructions in the operating manual 4 .......................................
4.2 Warning ...........................................................................................................4
5 Supplied items 5 ................................................................................................
6 Before first use 6 ...............................................................................................
7 Handhabung / Messung 6 ................................................................................
7.1 Calibration with the calibration block 7 .........................................................
7.2 Measuring procedure 8-9 ................................................................................
8 Cleaning and maintenance 10 .........................................................................
9 Storage .........................................................................................................11
10 Service.......................................................................................................... 11
11 Disposal ........................................................................................................ 12
12 Additional information 12 ................................................................................
1. Technische Daten
Models
KERN
Measuring ran-
ge and Scales
Scale gradua-
tions Accuracy
Dimensions
Product
Net weight
ORA 1 GG 0,01 nD 130x20x30mm 0,400kg
Operating manual
Analogue refractometer
KERN & Sohn GmbH
KERN ORA 1 GG Analogue nD
Gemology/gemstones
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433 -9933 -0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
GB 3. General information
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index
of gemstones. It is used to observe the behaviour of light as it passes from a prism
with known properties to the substance being tested.
Use of the refractometer for other purposes is contrary to its intended use and
may be hazardous. The manufacturer shall not be liable for any damages caused by
improper use.
3.2 Warranty
The warranty is void in the event of:
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
2. Description
1. Illumination aperture with filter
2. Cap
3. Polarisation filter
4. Prism
5. Eyepiece
6. Housing
2
3
6
4
5
1
Version 1. 0 /201 1 5 6
4. Basic safety information
4.1 Follow the instructions in the operating manual
Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
Every language version includes a non-authoritative translation.
The original German document is the definitive version.
4.2 Warning
Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for at
least 15 minutes. Then consult a doctor or ophthalmologist immediately.
Thoroughly clean the refractometer aer each use.
The refractometer must not be exposed to extreme temperatures, high mechanical
stresses, strong direct sunlight or high humidity.
This refractometer is not a toy. Keep out of reach of children.
Make sure that you will not be hit by anything else while you are using the refracto-
meter, as this could cause serious eye injuries
Do not touch the lenses with your fingers.
5. Supplied items
Aer unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Adjustment tool
▸ Cleaning cloth
▸ Contact liquid ( )Calibration block + Diiodomethane
6. Before first use
Remove the protective film (if present) from the prism surface [4].
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of gemstones. Please make sure your hands are dry before handling the
measuring device.
Some gemstones are monorefringent, they have only one refractive index. Other
gemstones - and actually the majority - have two different refractive indexes.
Birefringency is a measure of the difference between two refractive indexes in
bire-fringent gemstones and ranges between 0.003 and 0.287.
Only a very few gemstones are monorefringent – the only known gemstones
displaying this property are diamond, spinel and garnet.
The gemstone refractometer is small, lightweight and is frequently used in the
jewellery business.
Example scale on ORA 1 GG
RI: 1,30-1,81 nD

7
14
8
9
10
12
11
13
Important!
The ambient/room temperature and the sample temperature
influence the refractometer measuring result.
The scales are designed for an ambient temperature of +20 °C!
7.1 Calibration with the calibration block
Prior to any kind of measuring operation a calibration of the device has to be done.
Please put one drop of the contact liquid ( ) on the prism Diiodomethane [4]. Now put the
calibration block with the smooth and polished surface on the prism
[4]. Use only slight
pressure. There must not be any pimples between the calibration block and the prism.
Close the prism cover [2].
Now please look into the eyepiece.
You should read 1,515 at the light/dark boundary.
In case you read a different value the calibration of the refractometer has to be redone.
This recalibration can only be done in a dealers workshop.
After having finished please clean the refractometer. See point
[8].
7.2 Measuring procedure
*
▸ Make sure your hands are dry before handling the refractometer.
Put the refractometer always on a flat table surface and do not tilt or hold it up with your
hands during the entire measuring process.
▸ Open the prism cover [
2] and apply one drop only of the contact liquid* onto the
prism surface
[4]. Now place the gemstone with as flat a face as possible onto the
prism [4]. There is now an oil film between the gemstone and the prism [4]. Close
the prism cover [2] and wait about 30 seconds (for optimal temperature equalisation
between the sample and device).
▸ View the measurement scale through the eyepiece [5]. Point the refractometer‘s
illumination aperture
[1
] at a bright light source while doing this (If the daylight
should not be sufficient, you can use an additional LED.
▸ Raise or lower the eyepiece [5] to focus the optics.
▸ Depending on the type of gemstone the light/dark boundary on the scale reveals
the result.
▸ To determine the birefringency index unscrew the polarisation filter
[3] and place
it on the eyepiece
[5]. Bring the light/dark boundary on the scale into focus by
rotating the polarisation filter [3
] and read off the value. Now rotate the gemstone
by 90° and make a new measurement as described. Read off the second value.
▸ The difference between the first and the second value is the birefringency.
▸ For birefringent gemstones it is between 0.003 and 0.278. When the measure-
ments are complete screw the polarisation filter
[3] back into its mount
on the cover [8].
▸ Carefully clean the supplied pipette
[8] and the refractometer aer carrying out
the measurement.
Important!
Aer every measurement, use a lint-free, absorbent cloth to remove
the fluids from the prism surface [4]. Then carefully clean the prism
and prism cover using a cloth moistened with water or if necessary
alcohol, and dry both parts using a so, dry and lint-free cloth.
Avoid rubbing the prism [4]
.
!
8. Cleaning and maintenance
Clean the refractometer by using a so, lint-free cloth moistened with water, or if
necessary use pure alcohol. Do not use any aggressive or abrasive cleaning agents.
Never immerse the device in water or hold it under running water. Never handle the
device with wet or damp hands.
Never touch the measuring prism [4] with hard tools made from plastic, wood,
rubber, metal, glass etc. Hard objects can quickly damage the relatively so prism
glass, re-sulting in measurement errors.
The refractometer is maintenance-free.
Cleaning should be carried out immediately before and aer each use of the
refractometer to maximise its life and optimise measurement results.
9. Storage
Store the refractometer in a dry, non-corrosive environment, preferably between
10 °C and 30 °C.
10. Service
Aer reading this operating manual, if you have any questions about setting up
or using the refractometer, or if any unexpected problem occurs, please contact
your dealer. The device housing may only be opened by trained service
technicians authorised by KERN.
11. Disposal
The packaging consists of environmentally friendly materials which can be
disposed of via local recycling facilities.
The device and storage box should be disposed of by the operator in
accordance with applicable national or regional regulations at the place of use.
12. Additional information
The product may differ slightly from the illustrations. We reserve the right to
make changes to reflect technical advancements, decorations not included.
Avoid exposing the refractometer to direct sunlight!
Never bring the refractometer into contact with solvents.
!
*Further information on Measuring
The contact liquid (Diiodomethane), included with the standard outfit, has a
Refractive Index of 1.7425 nD.
If the gemstone to be tested has a Refractive Index, that is higher than 1.7425 nD,
another contact liquid (Anderson liquid), of which the Refractive Index is higher
than the Refractive Index of the gemstone, must be used.
Produktspecifikationer
Varumärke: | Kern |
Kategori: | Mätutrustning |
Modell: | ORA 1GG |
Behöver du hjälp?
Om du behöver hjälp med Kern ORA 1GG ställ en fråga nedan och andra användare kommer att svara dig
Mätutrustning Kern Manualer

29 Mars 2025

29 Mars 2025

29 Mars 2025

29 Mars 2025

26 Mars 2025

26 Mars 2025

28 Januari 2025

28 Januari 2025

28 Januari 2025

28 Januari 2025
Mätutrustning Manualer
- Mätutrustning Bosch
- Mätutrustning IKEA
- Mätutrustning Panasonic
- Mätutrustning DeWalt
- Mätutrustning Fysic
- Mätutrustning Honeywell
- Mätutrustning Pioneer
- Mätutrustning Topcom
- Mätutrustning Albrecht
- Mätutrustning Alecto
- Mätutrustning Ansmann
- Mätutrustning Amprobe
- Mätutrustning Toolland
- Mätutrustning Nedis
- Mätutrustning Black And Decker
- Mätutrustning Pyle
- Mätutrustning Yato
- Mätutrustning VirtuFit
- Mätutrustning Lanaform
- Mätutrustning Megasat
- Mätutrustning Meec Tools
- Mätutrustning Milwaukee
- Mätutrustning Extech
- Mätutrustning Victron Energy
- Mätutrustning ABB
- Mätutrustning Hazet
- Mätutrustning Schneider
- Mätutrustning Metrix
- Mätutrustning Benning
- Mätutrustning Einhell
- Mätutrustning Hama
- Mätutrustning Voltcraft
- Mätutrustning Midland
- Mätutrustning Mitsubishi
- Mätutrustning Velleman
- Mätutrustning Vemer
- Mätutrustning Technics
- Mätutrustning Perel
- Mätutrustning Burg-Wachter
- Mätutrustning Kyoritsu
- Mätutrustning IFM
- Mätutrustning Ideal
- Mätutrustning Flir
- Mätutrustning Homedics
- Mätutrustning Soehnle
- Mätutrustning Grohe
- Mätutrustning Technoline
- Mätutrustning Digitus
- Mätutrustning Soler And Palau
- Mätutrustning Proficare
- Mätutrustning Continental Edison
- Mätutrustning Dahua Technology
- Mätutrustning Rossmax
- Mätutrustning Microlife
- Mätutrustning Carrier
- Mätutrustning Testboy
- Mätutrustning Goclever
- Mätutrustning Trotec
- Mätutrustning LaCie
- Mätutrustning Laica
- Mätutrustning Danfoss
- Mätutrustning AS - Schwabe
- Mätutrustning Shimano
- Mätutrustning Goobay
- Mätutrustning Hager
- Mätutrustning Bresser
- Mätutrustning Festo
- Mätutrustning TFA
- Mätutrustning Owon
- Mätutrustning IHealth
- Mätutrustning Flex
- Mätutrustning Finder
- Mätutrustning Fluke
- Mätutrustning Fantini Cosmi
- Mätutrustning Eltako
- Mätutrustning EBERLE
- Mätutrustning Omnitronic
- Mätutrustning Basetech
- Mätutrustning Stabila
- Mätutrustning Eizo
- Mätutrustning Steinberg
- Mätutrustning Be Cool
- Mätutrustning Laserliner
- Mätutrustning Eurolite
- Mätutrustning Wentronic
- Mätutrustning Wago
- Mätutrustning Comark
- Mätutrustning REV
- Mätutrustning Testo
- Mätutrustning Sauter
- Mätutrustning Clean Air Optima
- Mätutrustning Bruder Mannesmann
- Mätutrustning Cocraft
- Mätutrustning VDO
- Mätutrustning Livington
- Mätutrustning Truelife
- Mätutrustning Eastron
- Mätutrustning ORNO
- Mätutrustning RIDGID
- Mätutrustning Maximum
- Mätutrustning Westfalia
- Mätutrustning Monacor
- Mätutrustning Metrel
- Mätutrustning Multimetrix
- Mätutrustning PCE
- Mätutrustning GW Instek
- Mätutrustning Logilink
- Mätutrustning Holzmann
- Mätutrustning SIIG
- Mätutrustning Oregon Scientific
- Mätutrustning Etymotic
- Mätutrustning Reely
- Mätutrustning Muller
- Mätutrustning TFA Dostmann
- Mätutrustning Werma
- Mätutrustning Greisinger
- Mätutrustning Testec
- Mätutrustning Beha-Amprobe
- Mätutrustning Kopp
- Mätutrustning YSI
- Mätutrustning Vimar
- Mätutrustning Kogan
- Mätutrustning Kreg
- Mätutrustning Kemo
- Mätutrustning Pancontrol
- Mätutrustning SRS
- Mätutrustning Peak
- Mätutrustning Uni-T
- Mätutrustning H-Tronic
- Mätutrustning X-Rite
- Mätutrustning Elgato
- Mätutrustning Ebro
- Mätutrustning Tempest
- Mätutrustning Arya
- Mätutrustning Hikmicro
- Mätutrustning RK Technology
- Mätutrustning PeakTech
- Mätutrustning Sonel
- Mätutrustning Tru Components
- Mätutrustning Emko
- Mätutrustning Aktobis
- Mätutrustning Entes
- Mätutrustning KS Tools
- Mätutrustning Lund
- Mätutrustning Phoenix Contact
- Mätutrustning Trumeter
- Mätutrustning Aeros
- Mätutrustning Delta Ohm
- Mätutrustning Aqua Master Tools
- Mätutrustning Hanna
- Mätutrustning Atmel
- Mätutrustning Qualita
- Mätutrustning MGL Avionics
- Mätutrustning Adwa
- Mätutrustning Chauvin Arnoux
- Mätutrustning Megger
- Mätutrustning AREXX
- Mätutrustning Gossen Metrawatt
- Mätutrustning Rigol
- Mätutrustning PCE Instruments
- Mätutrustning UHoo
- Mätutrustning CEM
- Mätutrustning NEO Tools
- Mätutrustning SHX
- Mätutrustning Hameg
- Mätutrustning TDE Instruments
- Mätutrustning CESYS
- Mätutrustning Joy-it
- Mätutrustning Angler
- Mätutrustning Techno Line
- Mätutrustning Circutor
- Mätutrustning Wachendorff
- Mätutrustning Klein Tools
- Mätutrustning Jonard Tools
- Mätutrustning Aim TTi
- Mätutrustning Duro Pro
- Mätutrustning Aerospace Logic
- Mätutrustning Grundfos
- Mätutrustning Zircon
- Mätutrustning BJZ
- Mätutrustning Johnson Level
- Mätutrustning GMW
- Mätutrustning SOEKS
- Mätutrustning Rotronic
- Mätutrustning Apollo Ultrasonic
- Mätutrustning Softing
- Mätutrustning Weltron
- Mätutrustning Oscium
- Mätutrustning Janitza
- Mätutrustning Sanwa
- Mätutrustning Condtrol
- Mätutrustning J.P. Instruments
- Mätutrustning MSW
- Mätutrustning Weidmüller
- Mätutrustning Qubino
- Mätutrustning Lascar Electronics
- Mätutrustning HT Instruments
- Mätutrustning BAXTER
- Mätutrustning P3 International
- Mätutrustning Beckmann & Egle
- Mätutrustning Seek Thermal
- Mätutrustning INFICON
- Mätutrustning Motrona
- Mätutrustning Tempo
- Mätutrustning Camille Bauer
- Mätutrustning Blebox
- Mätutrustning Seaward
- Mätutrustning HOZO Design
- Mätutrustning Corentium
- Mätutrustning GQ
- Mätutrustning Tektronix
- Mätutrustning Dostmann Electronic
- Mätutrustning Murideo
- Mätutrustning SecuTech
- Mätutrustning NetPeppers
- Mätutrustning SensoProtect
- Mätutrustning Water-i.d.
- Mätutrustning ZKETECH
- Mätutrustning LabNation
- Mätutrustning Electronics International
- Mätutrustning Cliff
- Mätutrustning ClimeMET
- Mätutrustning Fixpoint
- Mätutrustning Kübler
- Mätutrustning AkYtec
- Mätutrustning Stahlwille
- Mätutrustning MASIMO
- Mätutrustning Milesight
- Mätutrustning Enda
- Mätutrustning CSL
- Mätutrustning Ermenrich
- Mätutrustning PICO
- Mätutrustning Siglent
- Mätutrustning Noyafa
- Mätutrustning Topex
- Mätutrustning Stamos
- Mätutrustning Brookhuis
- Mätutrustning Senseca
- Mätutrustning PQ Plus
- Mätutrustning Intact
- Mätutrustning Crowcon
- Mätutrustning Aeroqual
- Mätutrustning DriveTest
- Mätutrustning Helvi
- Mätutrustning Mitutoyo
Nyaste Mätutrustning Manualer

30 Mars 2025

30 Mars 2025

30 Mars 2025

30 Mars 2025

30 Mars 2025

30 Mars 2025

30 Mars 2025

30 Mars 2025

29 Mars 2025

29 Mars 2025