RF-SM-DC-CA USER’S GUIDE
Wireless, Battery-Powered, Single and/or Multiple Station (12 smoke alarms maximum)
Ionization Smoke Alarm with
Smart HUSHControl to temporarily silence nuisance alarms.
This alarm detects products of combustion using the ionization technique. It contains 0.9
microcurie of Americium 241, a radioactive material (see Section 9). Distributed under U.S.
NRC License No. 32-23858-01E. Manufactured in compliance with U.S. NRC safety criteria in
10 CFR 32.27. The purchaser is exempt from any regulatory requirements. Do not try to
repair the smoke alarm yourself. Refer to the instructions in Section 13 for service.
WARNING! Ionization sensing alarms may detect invisible fire particles
(associated with fast flaming fires) sooner than photoelectric alarms.
Photoelectric sensing alarms may detect visible fire particles (associated with
slow smoldering fires) sooner than ionization alarms. Home fires develop in
different ways and are often unpredictable. For maximum protection, Kidde
recommends that both Ionization and Photoelectric alarms be installed.
WARNING! REMOVAL OF THE SMOKE ALARM BATTERIES WILL RENDER THE
SMOKE ALARM INOPERATIVE.
IMPORTANT! READ ALL INSTRUCTIONS BEFORE INSTALLATION AND KEEP THIS
USER’S GUIDE NEAR THE ALARM FOR FUTURE REFERENCE.
This alarm is interconnect compatible only with other RF-SM-DC-CA alarms.
CONTENTS
1 RECOMMENDED LOCATIONS FOR SMOKE ALARMS
2 LOCATIONS TO AVOID
3 INSTALLATION INSTRUCTIONS
4 OPERATION AND TESTING
5 NUISANCE ALARMS
6 MAINTENANCE
7 LIMITATIONS OF SMOKE ALARMS
8 GOOD SAFETY HABITS
9 NRC INFORMATION
10 NFPA REQUIRED PROTECTION
11 TROUBLE SHOOTING GUIDE
12 SERVICE AND WARRANTY
1. RECOMMENDED LOCATIONS FOR ALARMS
• Locate the first alarm in the immediate area of the bedrooms. Try to monitor the exit
path as the bedrooms are usually farthest from the exit. If more than one sleeping area
exists, locate additional alarms in each sleeping area (see IMAGE 1A).
• Locate additional alarms to monitor any stairway as they act as chimneys for smoke and heat.
• Locate at least one alarm on every floor (see IMAGE 1B).
• Locate an alarm in every bedroom.
• Locate an alarm in every room where electrical appliances operate (i.e. portable heaters
or humidifiers).
• Locate an alarm in every room where someone sleeps with the door closed. The closed
door may prevent an alarm not located in that room from waking the sleeper.
• Smoke, heat, and combustion products rise to the ceiling and spread horizontally.
Mounting the smoke alarm in the center of the ceiling places it closest to all points in the
room. Ceiling mounting is preferred in ordinary residential construction.
• For mobile home installation, select locations carefully to avoid thermal barriers that may
form at the ceiling. For more details, see MOBILE HOME INSTALLATION.
• When mounting an alarm on the ceiling, locate it at a minimum of 10 cm (4") from the
sidewall (see IMAGE 2A).
• When mounting the alarm on the wall, use an inside wall with the top edge of the alarm
at a minimum of 10 cm (4") and a maximum of 30.5 cm (12") below the ceiling (see
IMAGE 2A).
• Put smoke alarms at both ends of a bedroom hallway or large room if the hallway or
room is more than 9.1 m (30') long.
DINING
ROOM
LIVING
ROOM
Smoke Alarms for Minimum Protection
Ionization Type Smoke Alarm with
Hush® Control or Photoelectric Type
Smoke Alarms for Additional Protection
KITCHEN BEDROOM
BEDROOM
BEDROOM
LIVING
ROOM KITCHEN
BEDROOMBEDROOM HALL
BASEMENT
IMAGE 1A IMAGE 1B
SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN

Produktspecifikationer

Varumärke: Kidde
Kategori: Rökdetektor
Modell: 900-0201

Behöver du hjälp?

Om du behöver hjälp med Kidde 900-0201 ställ en fråga nedan och andra användare kommer att svara dig




Rökdetektor Kidde Manualer

Rökdetektor Manualer

Nyaste Rökdetektor Manualer