Sida 1/17

Manual P/N 820-1685 Rev B 10/12 2512-7213-00
ATTENTION: Please take a few minutes to thoroughly read this
user’s guide which should be saved for future reference and
passed on to any subsequent owner.
Carbon Monoxide Alarm
User’s Guide
Models: KN-COB-IC and KN-COP-IC
KN-COB-IC
KN-COP-IC
with Digital Display
• 120V AC Wire-In
• 9V Battery Backup
• Interconnectable with other Kidde alarms

Carbon Monoxide Alarm Procedure
1) Operate the Test/Reset button;
2) Call your emergency services (Fire Department or 911);
3) Immediately move to fresh air - outdoors or by an open
door/window. Do a head count to check that all persons are
accounted for. Do not reenter the premises nor move away
from the open door/window until the emergency services
responders have arrived, the premises have been aired out, and
your alarm remains in its normal condition.
4) After following steps 1-3, if the alarm reactivates within a 24
hour period, repeat steps 1-3 and call a qualified appliance
technician to investigate sources of CO from fuel burning
equipment and appliances, and to inspect for proper operation
of equipment.
If problems are identified during this inspection, have the equip-
ment serviced immediately. Note any combustion equipment not
inspected by the technician and consult the manufacturer’s instruc-
tions, or contact the manufacturer’s directly for more information
about CO safety and the equipment. Make sure that motor vehicles
are not, or have not been, operating in a garage attached or adja-
cent to the residence.
Never restart the source of a CO problem until it has been
corrected. Never ignore the sound of the alarm!
If the alarm is sounding, pressing the test/reset button will
terminate the alarm. If the CO condition that caused the alert
in the first place continues, the alarm will reactivate. If the
unit alarms again within six minutes, it is sensing high levels
of CO which can quickly become a dangerous situation.
WARNING:
Activation of the CO
Alarm indicates the presence of Carbon
Monoxide (CO) which can kill you.
PHONE NUMBER:
PHONE NUMBER:
What to do When the Alarm Sounds!

Important Warning Statements
WARNING:
WARNING:
WARNING:
WARNING:WARNING: This product is intended for use in ordinary
indoor locations of family living units. It is not designed to
measure compliance with Occupational Safety and Health
Administration (OSHA), commercial or industrial standards. It is
not suitable for installation in hazardous locations as defined in
the National Electric Code.
The installation of this device should not be used as a substitute
for proper installation, use and maintenance of fuel burning
appliances, including appropriate ventilation and exhaust sys-
tems. It does not prevent CO from occurring, nor can it solve an
existing CO problem.
WARNING:
WARNING:
WARNING:
WARNING:WARNING: This device is designed to protect individuals from
acute effects of carbon monoxide exposure. It may not fully safe-
guard individuals with specific medical conditions. If in doubt,
consult a medical practitioner.
Individuals with medical problems may consider using warning
devices which provide audible and visual signals for carbon
monoxide concentrations under 30 PPM.
This carbon monoxide alarm requires a continuous supply of elec-
trical power – it will not work without power. Models without
battery backup will not operate during power failure.
This alarm has not been investigated for carbon monoxide detec-
tion below 70 PPM.
Contents of This User’s Guide
1. Information About Carbon Monoxide
2. Product Features and Specifications
3. Installation Locations
4. Installation Instructions
5. Alarm Characteristics
6. KN-COB-IC Operating Characteristics
7. KN-COP-IC (with digital display) Operating Characteristics
8. Maintenance
9. Limited Warranty
!
!
Produktspecifikationer
Varumärke: | Kidde |
Kategori: | Gasdetektor |
Modell: | KN-COP-IC |
Behöver du hjälp?
Om du behöver hjälp med Kidde KN-COP-IC ställ en fråga nedan och andra användare kommer att svara dig
Gasdetektor Kidde Manualer

25 Oktober 2024

26 September 2024

26 September 2024

5 September 2024

24 Augusti 2024

23 Augusti 2024

20 Augusti 2024

20 Augusti 2024

18 Augusti 2024

17 Augusti 2024
Gasdetektor Manualer
- Gasdetektor Abus
- Gasdetektor Alecto
- Gasdetektor AngelEye
- Gasdetektor Nedis
- Gasdetektor Eminent
- Gasdetektor Elro
- Gasdetektor Techly
- Gasdetektor Vemer
- Gasdetektor Smartwares
- Gasdetektor Dahua Technology
- Gasdetektor Trotec
- Gasdetektor Netatmo
- Gasdetektor FireAngel
- Gasdetektor First Alert
- Gasdetektor Konig
- Gasdetektor Fantini Cosmi
- Gasdetektor HQ
- Gasdetektor Nexa
- Gasdetektor Satel
- Gasdetektor Testo
- Gasdetektor ORNO
- Gasdetektor Itron
- Gasdetektor Vimar
- Gasdetektor Gloria
- Gasdetektor System Sensor
- Gasdetektor Pentatech
- Gasdetektor PCE Instruments
- Gasdetektor Joy-it
- Gasdetektor WisuAlarm
- Gasdetektor Schabus
- Gasdetektor Protector
- Gasdetektor Airthings
- Gasdetektor Deltronic
- Gasdetektor Gewiss
- Gasdetektor Figaro
- Gasdetektor GEV
Nyaste Gasdetektor Manualer

1 April 2025

27 Mars 2025

29 December 2024

28 December 2024

22 December 2024

16 December 2024

12 December 2024

22 Oktober 2024

24 September 2024

24 September 2024