LG PM12EP Bruksanvisning

Läs nedan 📖 manual på svenska för LG PM12EP (71 sidor) i kategorin Luftkonditionering. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/71
[Manufacturer] Arçelik LG Klima Sanayi ve Ticaret A. Ş.
[Representative] LG Electronics Inc. Eu Representative :
LG Electronics European Shared Service Center B. V.
Krijgsman 1. 1186 DM Amstelveen, The Netherlands
Gebze Organize Sanayi Bölgesi İhsan Dede Caddesi
No:139 41480 Gebze / Kocaeli
P/No: 5401156154 Rev.:
Model Suffix
2MODEL DESIGNATION
ENGLISH
MODEL DESIGNATION
- Product Name : Air conditioner
- Product Name : Air conditioner
- Product Name : Air conditioner
- Product Name : Air conditioner- Product Name : Air conditioner
- Model Name :
- Model Name :
- Model Name :
- Model Name :- Model Name :
- Additional Information : serial number is
- Additional Information : serial number is
- Additional Information : serial number is
- Additional Information : serial number is- Additional Information : serial number is
refer to the barcode on the product.
refer to the barcode on the product.
refer to the barcode on the product.
refer to the barcode on the product.refer to the barcode on the product.
- Max allowable pressure High side :
- Max allowable pressure High side :
- Max allowable pressure High side :
- Max allowable pressure High side : - Max allowable pressure High side :
4.2 Mpa / Low side : 2.4 Mpa
4.2 Mpa / Low side : 2.4 Mpa
4.2 Mpa / Low side : 2.4 Mpa
4.2 Mpa / Low side : 2.4 Mpa4.2 Mpa / Low side : 2.4 Mpa
- Refrigerant : R410A
- Refrigerant : R410A
- Refrigerant : R410A
- Refrigerant : R410A- Refrigerant : R410A
Product information The A-weighted sound pressure emitted by
this product is below 70 dB.
** The noise level can vary depending on the
site.
The figures quoted are emission level and are
not necessarily safe working levels.
Whilst there is a correlation between the
emission and exposure levels, this cannot be
used reliably to determine whether or not
further precautions are required.
Factor that influence the actual level of
exposure of the workforce include the
characteristics of the work room and the other
sources of noise, i.e. the number of
equipment and other adjacent processes and
the length of time for which an operator
exposed to the noise. Also, the permissible
exposure level can vary from country to
country.
This information, however, will enable the
user of the equipment to make a better
evaluation of the hazard and risk.
Limiting concentration is the limit of Freon gas
concentration where immediate measures can
be taken without hurting human body when
refrigerant leaks in the air. The limiting
concentration shall be described in the unit of
kg/m3(Freon gas weight per unit air volume)
for facilitating calculation
nCalculate refrigerant concentration
Calculate refrigerant concentration
Calculate refrigerant concentration
Calculate refrigerant concentrationCalculate refrigerant concentration
Total amount of replenished
refrigerant in refrigerant facility (kg)
Capacity of smallest room where
indoor unit is installed (m3)
Refrigerant
concentration
(kg/m3)
=
Limiting concentration: 0.44kg/m3(R410A)
Airborne Noise Emission
Limiting concentration
P
P
P
PP M
M
M
MM S
S
S
SS P
P
P
PP
07
07
07
0707 N
N
N
NN SJ
SJ
SJ
SJSJ
(7) Chassis
(6) Indoor(N)
(5) Serial
(4) Product Look
(3) Capacity (kBTU)
(2) Product
(1) Product Type 1
(1) Product Type 1
D
D
D
DD Deluxe
P
P
P
PP Standard Plus/Standard
A
A
A
AA Artcool
(4) Product Look
R
R
R
RR R-Look
S
S
S
SS Semi R-Look
E
E
E
EE E-Look
B
B
B
BB Black Mirror Look
M
M
M
MM Multi Compitable
(2) Product
SJ
SJ
SJ
SJSJ Chassis
SK
SK
SK
SKSK Chassis
(7) Chassis
IMPORTANT SAFETY INSTRUCTIONS 3
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure
peak performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and oth-
ers.
• Installation work must be performed in accordance with the National Electric Code by
qualified and authorized personnel only.
• The information contained in the manual is intended for use by a qualified service techni-
cian familiar with safety procedures and equipped with the proper tools and test instru-
ments.
• Failure to carefully read and follow all instructions in this manual can result in equipment
malfunction, property damage, personal injury and/or death.
Installation
• Do not use a defective or underrated circuit breaker. Use the correctly rated breaker and
fuse. There is risk of fire or electric shock.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized
Service Center. Do not disassemble or repair the product by yourself. There is risk of fire
or electric shock.
• Always ground the product as per the wiring diagram. Do not connect the ground wire to
gas or water pipes lightening rod or telephone ground wire. There is risk of fire or electric
shock.
• Install the panel and the cover of control box securely. There is risk of fire or electric
shock due to dust, water etc.
• Use the correctly rated breaker or fuse. There is risk of fire or electric shock.
• Do not modify or extend the power cable. If the power cable or cord has scrathes or skin
peeled off or deteriorated then it must be replaced. There is risk of fire or electric shock.
• For installation, removal or reinstall, always contact the dealer or an Authorized Service
Center. There is risk of fire, electric shock, explosion, or injury.
• Do not install the product on a defective installation stand. Be sure that the installation
area does not deteriorate with age. It may cause product to fall.
• Never install the outdoor unit on a moving base or a place from where it can fall down.
!
!
!

Produktspecifikationer

Varumärke: LG
Kategori: Luftkonditionering
Modell: PM12EP

Behöver du hjälp?

Om du behöver hjälp med LG PM12EP ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering LG Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer