Doc 6001309 (01-20289) Page 1 of 2 Rev A
Use the following procedure to remove and replace a LiftMaster Swing Gate Operator cover:
WARNING
Failure to follow the instructions in Step 1 may cause injury due to unexpected gate movement.
Always wait one minute after power-off to service the gate.
1. Turn off power to the gate operator at the circuit breaker and wait for one minute. The gate
will move after one minute if system has the Power Fail Option.
2. When you are certain that the gate will not move due to Power Fail Option operation:
A) Disconnect the Drag Link from the gate Anchor.
B) Loosen the locking nut and mounting bolt, then remove the Swing Arm Cap Assembly and
Drag Link Assembly from the drive shaft. Set this assembly aside.
3. Remove the four cover mounting bolts and remove the gate operator cover.
4. If new cover has optional door: Remove the two top mounting screws from the control box clear
plastic cover. NOTE: These screws must be removed or the control box clear plastic cover cannot
be removed through the gate operator cover door.
5. Install the new gate operator cover and secure with mounting hardware.
6. Reinstall the Drag Link, Swing Arm and Swing Arm Cap Assemblies.
7. Turn on power to the gate operator at the circuit breaker.
Swing Gate Cover Removal and Installation.
SWING GATE OPERATOR COVER
REMOVAL AND INSTALLATION
(WITH OR WITHOUT DOOR)
COPYRIGHT 2001
ALL RIGHTS RESERVED
This document is protected by copyright and may not be copied or adapted without the prior written consent of
LiftMaster. This documentation contains information proprietary to LiftMaster and such information may not be
distributed without the prior written consent of LiftMaster. The software and firmware included in the LiftMaster
product as they relate to this documentation are also protected by copyright and contain information proprietary
to LiftMaster.
FOR TECHNICAL SUPPORT
Call our toll free numbers:
(800) 323-2276
(800) 998-9197
Installation and service information is
available six days a week.
TO ORDER REPAIR PARTS
Call our toll free numbers:
(800) 528-2806
(800) 998-9197
Prepare to provide the following
information when ordering repair parts:
Part Number
Part Name
Model Number

Produktspecifikationer

Varumärke: Liftmaster
Kategori: Inte kategoriserad
Modell: LA400UL

Behöver du hjälp?

Om du behöver hjälp med Liftmaster LA400UL ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Liftmaster Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer