Midea MSAGB-12CRN8-PC6 Bruksanvisning

Midea Luftkonditionering MSAGB-12CRN8-PC6

Läs nedan 📖 manual på svenska för Midea MSAGB-12CRN8-PC6 (51 sidor) i kategorin Luftkonditionering. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/51
SPLIT-TYPE ROOM AIR CONDITIONER
Owner’s Manual &
Installation Manual
IMPORTANT NOTE:
Read this manual carefully before installing
or operating your new air conditioning
unit. Make sure to save this manual for
future reference.
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the “Owner's Manual - Product Fiche ”
in the packaging of the outdoor unit.
(European Union products only)
Unit Specifications and Features
.............................................................................07
Owner’s Manual
Installation Manual
Table of Contents
Safety Precautions
................................................................................................03
Care and Maintenance............................. .....................11.......................................
Troubleshooting............................... 13.....................................................................
1. Indoor unit display..................................................................................................................................................07
2. Operating temperature...........................................................................................................................................08
3. Other features .......................................................................................................................................................09
4. Setting angle of airflow..........................................................................................................................................10
5. Manual operation (without Remote).......................................................................................................................10
Accessories..............................................................................................................16
Unit Parts.................................................................................................................18
Indoor Unit Installation.........................................................................................19
1. Select installation location.........................................................................................................................................19
2. Attach mounting plate to wall...................................................................................................................................19
3. Drill wall hole for connective piping...........................................................................................................................20
4. Prepare refrigerant piping..........................................................................................................................................21
5. Connect drain hose...................................................................................................................................................21
6. Connect signal and power cables..............................................................................................................................22
7. Wrap piping and cables.............................................................................................................................................23
8. Mount indoor unit....................................................................................................................................................24
Outdoor Unit Installation...............................................................................................25
1. Select installation location...........................................................................................................................................25
2. Install drain joint.........................................................................................................................................................26
3. Anchor outdoor unit...................................................................................................................................................26
4. Connect signal and power cables................................................................................................................................28
Refrigerant Piping Connection..............................................................................29
A. Note on Pipe Length..................................................................................................................................................29
B.
Connection Instructions –Refrigerant Piping...............................................................................................................29
1. Cut pipe...............................................................................................................................................................29
2. Remove burrs.......................................................................................................................................................30
3. Flare pipe ends.....................................................................................................................................................30
4. Connect pipes......................................................................................................................................................30
Air Evacuation.........................................................................................32
1. Evacuation Instructions...........................................................................................................................32
2. Note on Adding Refrigerant....................................................................................................................33
Electrical and Gas Leak Checks...............................................................34
Test Run....................................................................................................35
Installation Summary - Indoor Unit .....................................................................17
Safety
Precautions
Read Safety Precautions Before Operation and Installation
The seriousness of potential damage or injuries is classified as either a or .WARNING CAUTION
Incorrect installation due to ignoring instructions can cause serious damage or injury.
WARNING
This appliance can be used by children aged from 8 years and above and persons with reduced
This appliance is not intended for use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance.
physical, sensory or mental capabilities or lack of experience and knowledge if they have been given
supervision or instruction concerning use of the appliance in a safe way and understand the hazards
involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be
made by children without supervision European Union countries .( )
WARNINGS FOR PRODUCT USE
If an abnormal situation arises (like a burning smell), immediately turn off the unit and disconnect
the power. Call your dealer for instructions to avoid electric shock, fire or injury.
Do not
insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since
the fan may be rotating at high speeds.
Do not
use flammable sprays such as hair spray, lacquer or paint near the unit. This may cause
fire or combustion.
Do not
operate the air conditioner in places near or around combustible gases. Emitted gas may
collect around the unit and cause explosion.
Do not
Do not
expose your body directly to cool air for a prolonged period of time.
If the air conditioner is used together with burners or other heating devices, thoroughly ventilate
the room to avoid oxygen deficiency.
Safety Precautions
Do not
allow children to play with the air conditioner. Children must be supervised around the
unit at all times.
operate your air conditioner in a wet room such as a bathroom or laundry room. Too
much exposure to water can cause electrical components to short circuit.
In certain functional environments, such as kitchens, server rooms, etc., the use of specially
designed air-conditioning units is highly recommended.
Page 3
WARNING
This symbol indicates the possibility
of personnel injury or loss of life.
CAUTION
This symbol indicates the possibility of
property damage or serious consequences.

Produktspecifikationer

Varumärke: Midea
Kategori: Luftkonditionering
Modell: MSAGB-12CRN8-PC6
Färg på produkten: Wit
Vikt: 550 g
Bredd: 149 mm
Djup: 149 mm
Höjd: 101 mm
Snäll: IP-beveiligingscamera
Husmaterial: Polycarbonaat (PC)
Internationell säkerhetskod (IP): IP52
Vormfaktor: Dome
Placeringsstöd: Binnen & buiten
Anslutningsteknik: Bedraad
Ethernet LAN: Ja
Monteringsmetod: Plafond/muur
Maximal upplösning: 3072 x 1728 Pixels
Totalt antal megapixlar: 5 MP
Videokomprimeringsformat: H.264, M-JPEG, MPEG4
Typ av strömkälla: Power over Ethernet (PoE)
Minimal belysning: 0 Lux
Antal kameror: 1
Integrerad minneskortläsare: Ja
Kompatibla minneskort: MicroSD (TransFlash), MicroSDHC, MicroSDXC
Inbyggd hårddisk: Nee
Nattseende: Ja
LED-typ: IR
Infraröd våglängd: 850 nm
Video rörelsedetektering: Ja
HTTPS-kryptering: Ja
Antal Ethernet LAN (RJ-45)-portar: 1
Brännvidd: 3.5 - 10 mm
Inbyggda högtalare: Nee
Strömförbrukning (max): 11.5 W
Optisk sensorstorlek: 1/2.5 "
Bildsensortyp: CMOS
Kamerans slutartid: 1/62500 - 2 s
Inbyggd mikrofon: Nee
Internminne: 1024 MB
Password bescherming: Gebruiker
Grafikupplösningar som stöds: 3072 x 1728,160 x 90
Kabelteknik: 10/100Base-T(X)
Nätverksstandard: IEEE 802.3, IEEE 802.3af, IEEE 802.3at, IEEE 802.3u
Säkerhetsalgoritmer som stöds: 802.1x RADIUS, HTTPS, SSH, SSL/TLS
Stöder Windows: Ja
Förvaringstemperatur: -40 - 65 °C
Nätverksprotokoll som stöds: IPv4/v6, HTTP, HTTPS, SSL/TLS, QoS Layer 3 DiffServ, FTP, SFTP, CIFS/SMB, SMTP, Bonjour, UPnP, SNMP v1/v2c/v3 (MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, SOCKS, SSH
Webbaserad hantering: Ja
Fjärrstyrd: Ja
IP-adressfilter: Ja
Progressiv skanning: Ja
Flashminne: 512 MB
Ethernet-gränssnittstyp: Fast Ethernet
Språk som stöds: CHI (SIMPL), CHI (TR), DEU, ENG, FRE, ITA, JPN, KOR, POR, RUS
Quality of Service (QoS): Ja
Power over Ethernet (PoE): Ja
Jag kodar: IK08
Rotationsvinkel: 190 °
Panoreringsintervall: -180 - 180 °
Dag/nattläge: Ja
Minsta bländartal: 1.7
Videostreaming: Ja
Monteringsfästen ingår: Ja
Night vision scope: 30 m
Förinställda punkter: Ja
Antal språk: 11
Justering av bildkvalitet: Brightness, Colour depth, Contrast, Sharpness
Wide Dynamic Range (WDR): Ja
Wifi: Nee
Strömförbrukning (typiskt): 8.4 W
Drifttemperatur (TT): 0 - 50 °C
Relativ luftfuktighet i drift (VV): 10 - 85 procent
Tiltvinkelområde: -40 - 75 °
Mask privat zon: Ja
Linsens betraktningsvinkel, horisontell: 100 °
Typ av varningsmeddelande: E-mail
Linsens betraktningsvinkel, vertikal: 51 °
Aktivt larm för obehörig demontering: Ja
Automatisk spårning: Ja
Automatisk förstärkningskontroll: Ja
Textoverlay: Ja
Iris: Ja
Avtagbart IR-filter: Ja
PTZ-modi: Digital PTZ, Preset point

Behöver du hjälp?

Om du behöver hjälp med Midea MSAGB-12CRN8-PC6 ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Midea Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer