Mitsubishi PEA-RP250WHA Bruksanvisning

Läs nedan 📖 manual på svenska för Mitsubishi PEA-RP250WHA (13 sidor) i kategorin Luftkonditionering. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/13
Air-Conditioners
INDOOR UNIT
PEA-RP250 WHA
GB
INSTALLATION MANUAL
For safe and correct use, please read this installation manual thoroughly before installing the air-conditioner unit.
33.2
200
~
300
150
~
200
50
50
1350
730
450
470
more than 20
30
±
10
more than 20
more than 100
23 1324 23
371250
1100
1100800
1034
B
C
D
A
AE
Keep the service space for the maintenance from
the bottom when the heat exchanger is cleaned.
60
2
44.1
CNuts (field supply)
DWashers (accessory)
EM10 hanging bolt (field supply)
55.3
[Fig. 5.1.1] [Fig. 5.1.2] [Fig. 5.3.1]
5.1
66.2
[Fig. 6.2.1]
AIndoor unit’s bottom surface
701494
235
1034 1324
A
A
B
A
C
D
C
E
D
A BAir inlet Refrigerant piping (liquid)
C DRefrigerant piping (gas) Control box
E FDrain pipe Air outlet
165 52
100 244
30
424
A
B
E
C
D
F
[Fig. 4.1.1]
[Fig. 3.2.1]
AAccess door
BElectrical parts box
CAir inlet
DAir outlet
ECeiling surface
ACenter of gravity
AUnit body
BLifting machine
3
ACut here
BRemove brazed cap
7
[Fig. 7.1.1]
7.1
7.2
A
[Fig. 7.1.2]
ACool by a wet cloth
[Fig. 7.1.3]
20
20
20
20
AB
C
E
D
F
G
H
I
J
K
K
J
L
E
AThermal insulation tubing (small)
BCaution:
Pull out the thermal insulation on the refrigerant piping
at the site, braze the piping, and replace the insulation
in its original position.
Take care to ensure that condensation does not form on
exposed copper piping.
CRefrigerant piping (liquid)
DRefrigerant piping (gas)
EMain body
FThermal insulation tubing (large)
GSite refrigerant piping
HEnsure that there are no gaps between the insulation
and the main body.
IThermal insulation tubing (small) (supplied) 1
JTies (large) (supplied) 4
KEnsure that there is no gap here. Place join upwards.
LThermal insulation tubing (medium) (supplied) 2
MThermal insulation
NPull
OFlared pipe end
PWrap with damp cloth
QReturn to original position
REnsure that there is no gap here.
M
M
QR
P
O
N
[Fig. 7.2.2]
AIndoor unit
BInsulation pipe (short) (accessory)
CTie band (accessory)
DBand fixing part
EInsertion margin
FDrain hose (accessory)
GDrain pipe (O.D. ø32 PVC TUBE, field supply)
HInsulating material (field supply)
IMax.145 ± 5 mm
DEH
G
I
F
B
C
5 25
A
[Fig. 7.2.1]
AB1
CCC
D2
E
ADownward slope 1/100 or more
BDrain hose (Accessory)
CIndoor unit
DCollective piping
EMaximize this length to approx. 10 cm

Produktspecifikationer

Varumärke: Mitsubishi
Kategori: Luftkonditionering
Modell: PEA-RP250WHA

Behöver du hjälp?

Om du behöver hjälp med Mitsubishi PEA-RP250WHA ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Mitsubishi Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer