Napoleon Gemini BIPT750RBI Bruksanvisning

Napoleon Utegrill Gemini BIPT750RBI

Läs nedan 📖 manual på svenska för Napoleon Gemini BIPT750RBI (24 sidor) i kategorin Utegrill. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/24
APPLY SERIAL NUMBER LABEL FROM CARTON
Serial No.
XXXXXX000000
MODEL NO.
N415-0175 APR 17.14
BUILT–IN UNIT INSTRUCTION GUIDE
Please use this manual in conjuncon with your main manual to properly assemble your built-in grill. Refer to
the main manual for operang, cleaning, and maintenance instrucons.
WARNING! This grill is designed for enclosures only, and must be installed and

WARNING!
BUILT IN PROPANE GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this exible metal connector to the are ng on the end of the manifold.
Connect the other end of the connector to the gas piping. Ensure that the connector does not pass through a
wall, oor, ceiling or paron, and is protected from damage. Do not use a hose to connect the unit except to
connect the cylinder regulator to the piping system. It must be connected with rigid pipe, copper tube or an
approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane installaon code in Canada, or to the
Naonal Fuel Gas code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon. If the enclosure is to house a propane cylinder, the tank poron of the enclosure must be venlated
according to local codes, and must not have communicaon with the cavity used to enclose the gas grill. A
propane tank can not be stored below the gas grill.
BUILT IN CYLINDER ENCLOSURES: Built in cylinder enclosures which completely enclose the cylinder must have
both of the following:
1. At least one unobstructed venlaon opening on the exposed exterior side of the enclosure located within
5 in (127 mm) of the top of the enclosure. The opening must have a total free area of more than 20 in
2
(130
cm2)
for a 20 lb (9.1 kg) cylinder and 30 in2 (195 cm2) for a 30 lb (13.6 kg) cylinder.
2. At least one venlaon opening on the exposed, exterior side of the enclosure located 1 in (25.4 mm) or less
from the oor level. The opening must have a total free area of more than 10 in 2 (65 cm2) for a 20 lb (9.1 kg)
cylinder and 15 in2 (100 cm2) for a 30 lb (13.6 kg) cylinder. The upper edge must be no more than 5 in (127
mm) above the oor level.

www.napoleongrills.com
Napoleon Group of Companies



WARNING!
The cylinder valve(s) must be readily accessible for hand operaon. A door on the enclosure to gain access
to the cylinder valves is acceptable, provided it is non-locking and can be opened without the use of tools.
The enclosure for the LP-gas cylinder must isolate the cylinder from the burner compartment to provide
shielding from radiaon, a ame barrier, and protecon from foreign material, such as hot drippings. The
enclosure cannot be located directly below the grill.
There must be a minimum clearance of 2 in (51 mm) between the oor of the LP-gas cylinder enclosure
and the ground.
The enclosure must be designed so that the LP-gas cylinder can be connected, disconnected and the
connecons inspected and tested outside the cylinder enclosure. Any connecons that can be disturbed
when installing the cylinder in the enclosure must be accessible for tesng inside the enclosure.
BUILT IN NATURAL GAS HOOK-UP: The piping up to the gas grill is the responsibility of the installer and piping
should be located as shown in the built-in instrucons. A exible metal connector is included to simplify the
installaon of the unit. Connect this connector to the are ng on the end of the manifold. Connect the
other end of the connector to the gas piping. Ensure that the connector does not pass through a wall, oor,
ceiling or paron, and is protected from damage. Do not use hose to connect the unit. It must be connected
with rigid pipe, copper tube or an approved exible metal connector which complies with Z21.4 /CSA 6.10.
The installaon must comply with CAN B149.1 Natural Gas and Propane Installaon Code in Canada, or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States. The gas supply pipe must be suciently sized to
supply the BTU/h specied on the rang plate, based on the length of the piping run. If installing a side burner,
a separate line must be branched o to the side burner unit and enter the side burner opening at the specied
locaon.
WARNING! Built in units are supplied with a drip pan which holds only a minimal amount of grease.
To prevent grease res, the pan must be cleaned aer each use.
WARNING! Access must be provided to the inside of the enclosure to make gas connecons.
DANGER! Read all instrucons carefully before operang the grill. Failure to follow these instrucons
exactly could result in a re causing serious injury or death. The enre installaon must be leak tested
before operang the grill.
CYLINDER SIZE OPENING A AREA OPENING B AREA
20 lb (9.1kg) 20in2 (130cm2)10in2 (65cm2)
30 lb (13.6kg) 30in2 (195cm2)15in2 (100cm2)
5” (127mm)
MAXIMUM
1” (25.4mm)
MAXIMUM
OPENING
A
OPENING
B2” (51mm)
MINIMUM
PARTITION TO ISOLATE
CYLINDER FROM GRILL
NON LOCKING DOOR
34” (864mm)
RECOMMENDED
5” (127mm)
MAXIMUM
3
www.napoleongrills.com
MINIMUM 10 SQ IN OF
VENTILATION REQUIRED
ON EACH END OF CABINET
34” (864mm)
RECOMMENDED
BUILT-IN UNIT OPENING DIMENSIONS
OUTDOOR GFI ELECTRICAL OUTLET
REC
OMMENDED - LOCATE ON LEFT
SIDE OF GRILL FOR ROTISSERIE USE.
BIU405 BUILT-IN GRILL HEADS
BUILT-IN SIDEBURNER
2” (51mm)
3”(76mm) MIN.
6”(152mm)
W
D
H
1¾”
(44mm)
1¾”
(44mm)
4”(102mm)
7”(178mm)
H
H
DD
W
W
GAS INLET OPENING GAS INLET OPENING GAS INLET OPENING
NON-COMBUSTIBLE MATERIAL
CABINET FRAME AND CABINET MUST BE MADE FROM
NON-COMBUSTIBLE MATERIAL
BIPT450 / BIPT600 / BIPT750 BUILT-IN
GRILL HEADS
MODEL OPENING DIMENSIONS NOTES
W D H
BIPT450 29 1/2”
749mm
20 5/8”
524mm
8 7/8”
225mm
BIPT600 37 3/4”
959mm
20 5/8”
524mm
8 7/8”
225mm
BIPT750 49 3/4”
1264mm
20 5/8”
524mm
9 5/8”
244mm
BIU405 27 1/2”
699mm
16 3/4”
425mm
12”
305mm
ACCESS MUST BE PROVIDED FOR DRIP TRAY REMOVAL AND
CLEANING.
SIDE BURNER 12 3/4”
324mm
16 1/2”
419mm
4 1/2”
114mm
OPENING OF AT LEAST 5 SQ IN MUST BE PROVIDED FOR
COMBUSTION AIR FOR SIDE BURNER.

Produktspecifikationer

Varumärke: Napoleon
Kategori: Utegrill
Modell: Gemini BIPT750RBI

Behöver du hjälp?

Om du behöver hjälp med Napoleon Gemini BIPT750RBI ställ en fråga nedan och andra användare kommer att svara dig




Utegrill Napoleon Manualer

Utegrill Manualer

Nyaste Utegrill Manualer