Ozito ADR-PRO Bruksanvisning

Läs nedan 📖 manual på svenska för Ozito ADR-PRO (2 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
DESCRIPTION OF SYMBOLS SPARE PARTS
REVERSIBLE
AIR DRILL
3/8” Chuck
INSTRUCTION MANUAL
SPECIFICATIONS
ADR-PRO
Max Air Pressure: 90psi (6Bar)
Av. Air Consumption: 141.5l/min (5cfm)
No Load Speed: 1800/min
Chuck: 3/8” Keyed
Air Inlet: 1/4” BSP
Weight: 1.16kg
Chuck Key SPADRPRO-34
Spare parts can be ordered from the Special Orders
Desk at your local Bunnings Warehouse.
For further information, or any parts not listed here, visit
www.ozito.com.au or contact Ozito Customer Service:
Australia 1800 069 486
New Zealand 0508 069 486
Email: enquiries@ozito.com.au
Warning Read instruction
manual
Wear eye protection
No load speed
Wear ear protection
Revolutions or
reciprocaton per minute
/min no
GENERAL AIR TOOL SAFETY WARNINGS
WARNING! Read all safety warnings and all instructions. Failure to follow the
warnings and instructions may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference. The term “power tool” in the warnings
refers to your mains-operated (corded) power tool or battery-operated (cordless) power tool.
1. Work area safety
a. Cluttered or dark areas invite accidents. Keep work area clean and well lit.
b. Do not operate power tools in explosive atmospheres, such as in the presence of
flammable liquids, gases or dust. Power tools create sparks which may ignite the dust
or fumes.
c. Distractions can Keep children and bystanders away while operating a power tool.
cause you to lose control.
d. Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing
and gloves away from moving parts. Loose clothes, jewellery or long hair can be
caught in moving parts.
e. Check the maximum pressure rating of any tools or accessories that you intend using with
the compressor. The output pressure of the air from the compressor must be regulated so
that it never exceeds the rated pressure of the tool or accessory.
f. Always wear safety goggles or glasses when using the air compressor. Never point the
nozzle of an accessory towards any part of your body or towards another person.
g. Drain the moisture from the tank daily. It will help prevent corrosion.
h. Use safety equipment including safety goggles or shield, ear protection, breathing respirator
mask and protective clothing.
i. Air tools should not be used in a potentialy explosive environment.
j. Use safety equipment including safety goggles or shield, ear protection, breathing or
respirator mask and protective clothing.
k. Any use other than those mentioned The tool must be used only for its prescribed purpose.
in this Manual will be considered a case of misuse. The user and not the manufacturer
shall be liable for any damage or injury resulting from such cases of misuse.
WARNING! In the event that an air line is cut or broken, the air supply must be turned off
at the compressor. A broken air line which is not supported is extremely dangerous and
can whip around very quickly, both with the capability of striking people, and blowing foreign
particles into the air.
Do not attempt to catch the air line but immediately keep bystanders well clear and turn off the air
supply to the hose, turn off the compressor at the On / Off button, and then remove the hose from
the compressor.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given the supervision or instruction concerning use of the appliance by a person
responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
1 Keyed Chuck
2 Rear Chuck Sleeve
3 On/off Trigger
4 Forward/ Reverse Lever
5 Air Inlet
KNOW YOUR PRODUCT
CONNECTING TO COMPRESSOR
OPERATION
INSTALLING DRILL BITS
TROUBLESHOOTINGMAINTENANCE
If the air drill fails to work effecvely, perform the following checks:
Check the forward/ reverse lever is set to the correct direcon.
• Check that the pressure on the air compressor is within its
||working range. If not, let the compressor rest to|re-pressurise /
refer to the compressor instruction manual.
Note: Disconnect the tool from the air supply before installing or removing accessories.
Note: This tool is rated at 90psi. Ensure your compressor is set no higher than 90psi.
3. Screw the male nio fing
clockwise into the female end
of the drill.
4. Pull back the sleeve on hose
fing, insert male drill end &
release sleeve on hose fing.
1. Remove black plasc cap
from air inlet.
2. Wrap the threaded male
end with teflon tape in a
clockwise direcon.
3. Insert chuck key into 1 of the holes on chuck. Hold
rear sleeve while turning key clockwise. Repeat on the
remaining 2 chuck holes.
1. Rotate rear sleeve to
open chuck jaws.
2. Insert drill bit then hand
ghten chuck.
2. Select the direcon of rotaon
by pushing the forward/reverse
lever up for forward or down for
reverse rotaon.
1. To turn the drill on, squeeze the
on/off trigger. Release to turn off.
3. Aer each use, place one drop
of oil into the drill, through the
nio fing end.
• Keep the ventilation vents of the drill clean at all times, if
possible, prevent foreign matter from entering the vents.
• If the enclosure of the drill requires cleaning, do not use
solvents but a moist soft cloth only. Never let any liquid get inside
the drill; never immerse any part of the drill into a liquid.
Oil the drill after each use.

Produktspecifikationer

Varumärke: Ozito
Kategori: Inte kategoriserad
Modell: ADR-PRO

Behöver du hjälp?

Om du behöver hjälp med Ozito ADR-PRO ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Ozito Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer