Panamax M5300-PM Bruksanvisning

Läs nedan 📖 manual på svenska för Panamax M5300-PM (2 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
MAX® 5300-PM
LOOKING FOR CRYSTAL CLEAR PICTURE AND SOUND?
MAX 5300-PM®
www.panamax.com
Level 4 Power Cleaning and Filtration eliminates
common symptoms of contaminated power (including
loss of detail, pops, hisses, hums and visual artifacts)
and allows your A/V equipment to perform up to its full
capability.
1
2
Panamax’s patent pending AVM™ circuitry continuously
monitors the incoming power as displayed on the digital
voltmeter. In case of an undervoltage or an overvoltage, a
ashing red lightning bolt will be displayed in the voltmeter,
and power to the connected equipment is automatically
turned o if either of these conditions is detected. When
voltage returns to a safe level, power to the equipment is
automatically reconnected.
3
The M5300-PM is designed to provide noise isolation
between 5 isolated outlet banks (including 1 bank with 2
high current outlets) so that any noise created by an A/V
component cannot contaminate the power going to equip-
ment plugged into another outlet bank.
Improves Picture and Sound Quality
Monitors Incoming Line Voltage and Provides a
Visual Indication of Power Level
Reduces Cross-Contamination Between Components
11 Outlets
4 Always On, 5 Switched, 2 Switched High
Current.
High Current Outlets
2 outlets for equipment with high power
demands (Amps/Subwoofers).
5 Isolated Outlet Banks
Isolating outlet banks from one another
prevents noise contamination between
components.
Gaming LAN Port
Easy access to LAN port on front panel.
Perfect for online gaming.
Power Sequencing
Guards against blown fuses and potentially
damaging speaker thump by automatically
powering outlets on and o in sequence
12 Volt Trigger
Allows source equipment to activate or
deactivate the outlets on the M5300-PM
Clean Power Level 4
Improves picture and sound quality by
eliminating noise across the entire AC
bandwidth. 40% more ecient at eliminating
noise than Clean Power Level 3.
USB Charger
Convenience charger for mp3 players, cell
phones, and other small electronics
AVM (Automatic Voltage Monitoring)
Protects equipment against prolonged over/un-
der voltages by disconnecting the power and
reconnecting it when safe power returns
HOME THEATER POWER MANAGEMENT
MAX® 5300-PM BACK PANEL FEATURES
MAX® 5300-PM SPECIFICATIONS
UPC’S, QUANTITIES, WEIGHTS & MEASUREMENTS FOR ORDERING & SHIPPING
General________________________________________________________________
Dimensions .....................................17 in. W x 12.75 in. D x 3.5 in H, (4.1 in. Including feet)
Weight ........................................................................................................................30 lbs.
AC Power_______________________________________________________________
Line Voltage ........................................................................................................120V, 60Hz
Total Current Capacity ....................................................................................................15 A
UL1449 Suppression Rating ..........................................................................................330V
Protection Modes ............................................................................................L-N, L-G, N-G
Initial Clamping Level ...........................................................................200V Peak, 141 RMS
Energy Dissipation ..............................................................................................2350 Joules
Peak Impulse Current ...................................................................................... 72,000 Amps
Catastrophic Surge Circuit ...............................................................................................Yes
Thermal Fusing ................................................................................................................Yes
Over-voltage shuto ...................................................................................142 VAC ± 8 VAC
Under-voltage shuto ...................................................................................90 VAC ± 2 VAC
EMI/RFI Noise Filtration___________________________________________________
Banks 1, 2, 3, 4 .............................................................................. 80 db, 100 KHz – 2 MHz
Bank 5, High Current Outlets ......................................................... 60 db, 100 KHz – 2 MHz
DC Trigger Input__________________________________________________________
Jacks......................................................................................... 3.5mm (1/8”) mono mini-plug
Voltage and Polarity........................................................................3 - 24V DC, bidirectional
Current Requirement....................................................................4.6 mA @3V, 58 mA @24V
DC Trigger Output________________________________________________________
Pass through............................................................................................................no delay
Positive = Tip, Negative = Ring
Design and specications subject to change without notice due to product improvement.
LAN Circuits_____________________________________________________________
Clamping Level............................................................................................................... 50V
Connectors................................................................................................................... RJ-45
Wires Protected:....................................................................................................... 8-Wires
USB Circuit_____________________________________________________________
Jacks......................................................................................................................... USB-A
Power Delivery......................................................................................... 500 mA @ 5 VDC
Telco Circuit____________________________________________________________
Fuseless/Auto-resetting..................................................................................................Yes
Clamping Level.............................................................................................................260V
Capacitance....................................................................................................30pf (approx.)
Suppression Modes..........................................................................Metallic & Longitudinal
Wires Protected.......................................................................................2-Wire, Pins 4 & 5
Connectors..................................................................................................................RJ-11
Cable and Satellite Circuits________________________________________________
HD 1080 i/p Ready.........................................................................................................Yes
Shielded..........................................................................................................................Yes
Clamping Level...............................................................................................................75V
Frequency Range....................................................................................... 0 MHz - 2.2 GHz
Insertion Loss........................................................................................................... < 0.5 dB
Connections.....................................................................................Female “F”, Gold Plated
Bidirectional....................................................................................................................Yes
MODEL M5300-PM MASTER CARTONUNIT CARTON
Dimensions Weight Dimensions Weight UPC Qty Dimensions Weight UPC
17” x 12.75” x 3.5” 30 lbs 23.75” x 18.5” x 10” 33.5 Lbs 0 50616 00816 7 1 Same as 33.5 Lbs 5 00 50616 00816 2
4.1” H with feet Unit Carton
1690 Corporate Circle, Petaluma, CA. 94954 800-472-5555 or 707-283-5900 Fax 707-283-5901 www.panamax.com
© 2007 Panamax, Inc. Panamax, MAX, and the Panamax logo are registered US trademarks of Panamax L590 REV B 08/07
1. 15A Main Circuit
Breaker:
Automatically opens
when the current load
is greater than 15
Amps. Push to reset.
4. Outlet Banks 1 and 2
Each bank features two always-on outlets with
linear ltration technology (LiFT). Power will
only be turned o under a fault condition. (See
specications for over-voltage and under-voltage
thresholds). LiFT EMI/RFI noise ltration is
provided by a two-stage balanced Pi lter which
also provides noise isolation from all other
outlet banks.
5. Universal Coaxial
Connectors
3 pairs of bidirectional
protection circuits optimized for
satellite, cable, and antenna
TV signal lines.
3. Outlet Banks 3 and 4
Each bank features two switched outlets with linear
ltration technology (LiFT) controlled by the front
panel Power Button or the DC Trigger input. Banks
3 & 4 will turn on immediately and turn o after a
10 second delay. LiFT EMI/RFI noise ltration is
provided by a two-stage balanced Pi lter which
also provides noise isolation from all other outlet
banks.
2. Outlet Bank 5
Two switched, high-current outlets controlled by
the front panel Power Button or the DC Trigger in-
put. Bank 5 has a 5 second turn on delay and turns
o immediately upon shutdown. The High Current
outlets provide power from a low impedance noise
ltration circuit that does not limit the current to
your equipment. Its output is noise-isolated from all
other outlet banks.
6. Main Power Cord 10ft.
Must be plugged into a
properly wired & grounded
3-wire outlet.
8. Bank 1 & 2 Indicator
Light
Normally ON, is lit when
there is power present
on the Bank 1 and 2
receptacles.
11. LAN Jacks
Protection circuits for 10/100 baseT Ethernet
lines. For the LAN 2 protected jacks, the incom-
ing LAN line MUST be plugged into the LINE
jack and the patch cord to the equipment MUST
be plugged into the EQUIP jack. For the LAN 1
protected jacks the incoming LAN line must be
plugged into the LINE jack and the equipment
must be plugged into the gaming jack on the
front panel. 8 wire protection, 50V clamping.
10. Voltage Sense Trigger
Input
3.5mm (1/8”) mono mini-plug.
Connect to a remote trigger
device that uses a DC output
to trigger a startup/shutdown
sequence.
7. Ground Lug:
Provides a common
grounding point for
equipment with separate
ground leads.
12. Phone Jacks
Protection circuits for standard
telephone or pay-per-view lines.
Phone circuit is autoresetting.
Incoming phone cord MUST be
plugged into the LINE jack. Patch
cords to the equipment (satellite
receiver, digital video recorder,
telephone, etc.) MUST be plugged
into the EQUIP jacks.
9. Voltage Sense Trigger
Output
3.5mm (1/8”) Mini-Plug jack.
Connecting a trigger wire to
the Voltage Sense Output jack
will allow the input signal to
pass through the M5300-PM to
control the startup/shutdown of
an additional device.

Produktspecifikationer

Varumärke: Panamax
Kategori: Inte kategoriserad
Modell: M5300-PM

Behöver du hjälp?

Om du behöver hjälp med Panamax M5300-PM ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad Panamax Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer