Panasonic CS-E18DKEW Bruksanvisning

Läs nedan 📖 manual på svenska för Panasonic CS-E18DKEW (8 sidor) i kategorin Luftkonditionering. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/8
F564983
Operating Instructions
Air Conditioner
CS-E18DKEW CU-E18DKE
CS-E21DKES CU-E21DKE
Manufactured by:
Panasonic HA Air-Conditioning (M) Sdn. Bhd.
Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.
ENGLISH 2 ~ 7 Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento
de consulta. 8 ~ 13
ITALIANO Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento
in futuro. 14 ~ 19
NEDERLANDS 20 ~ 25Lees voor u het apparaat gebruikt deze gebruiksinstructies grondig na en bewaar ze voor toekomstig gebruik.
PORTUGUÊS 26 ~ 31Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência.
EΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά. 32 ~ 37
БЪЛГАРСКИ Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки. 38 ~ 43
2
The appliance is not intended for use by young children or infirm
person without supervision. Young children should be supervised to
ensure that they do not play with the appliance.
Thank you for purchasing Panasonic Air Conditioner
SAFETY PRECAUTIONS
Definition
Safety Regulation Operation Condition (OC)
Use this air conditioner under the following temperature
range.
DBT: Dry Bulb Temperature
WBT: Wet Bulb Temperature
Indoor Outdoor
DBT WBT DBT WBT
Maximum Temperature (COOL)
32 23 43 26
Maximum Temperature (HEAT)
30 – 24 18
Minimum Temperature (COOL)
16 11 16 11
Minimum Temperature (HEAT)
16 -5 -6
This sign warns of death
or serious injury.
To prevent personal injury,
injury to others and property
damage, the following
instructions must be
followed.
Incorrect operation due to
failure to follow instructions
will cause harm or damage,
the seriousness of which is
classified as below:
This symbol denotes
an action that is
PROHIBITED.
These symbols denote
actions that are
COMPULSORY.
Warning
This sign warns of injury
or damage to property.
Caution
The instructions to be
followed are classified by
the following symbols:
Installation Precautions
Caution
Do not wash the unit with water, benzene,
thinner or scouring powder.
Do not use for other purposes such as
preservation of food.
Do not use any combustible equipment at
airflow direction.
Do not sit or place anything on the indoor
or outdoor unit.
Do not expose directly to cold air for a
long period.
Ventilate the room regularly.
Pay attention as to whether the
installation rack is damaged after long
period of usage.
Switch off the power supply before
cleaning or servicing.
Turn off the power supply if the unit is not
used for a long period of time.
Operation Precautions
Use specified supply cord.
If the supply cord is damaged or needed
to be replaced, it must be replaced by
the manufacturer or its service agent or
a similarly qualified person in order to
avoid a hazard.
Remove the batteries if the unit is not
going to be use for a long period of time.
New batteries of the same type must be
inserted following the polarity stated to
prevent malfunction of the remote control.
In case of emergency or abnormal
condition (burnt, smell, etc) occurs, turn
off the power supply.
Warning
Do not share power outlet.
Do not modify power cord.
Do not use an extension cord.
Do not operate with wet hands.
Do not insert finger or other objects into the
indoor or outdoor unit.
Do not attempt to repair the unit by
yourself.
Do not use rechargeable (Ni-Cd) batteries.
Keep the remote control away from infants
and small children to prevent them from
accidentally swallowing the batteries.
Warning
Do not install, remove and reinstall the unit by yourself.
Improper installation will cause leakage, electric shock or fire. Please consult an authorized dealer or
specialist for the installation work.
This equipment must be earthed and installed with ELCB. It may cause electrical shock or fire in case of
malfunction.
Caution
This air conditioner must be earthed. Improper grounding will cause electric shock.
Ensure that the drainage piping is connected properly. Otherwise, water will leak.
Do not install the unit in a potentially explosive atmosphere.
3
ENGLISH
Note: The illustrations in this manual are for explanation purposes only and may differ from the
actual unit. It is subjected to change without notice for future improvement.
PRODUCT OVERVIEW
Outdoor Unit
Air inlet (rear)
Air outlet
Troubleshooting
Operation delayed for few minutes after restart. This is a normal self protection control.
Sound like water flowing during operation. Caused by refrigerant flow inside.
Mist emerges from indoor unit. Condensation effect due to cooling process.
Noisy during operations. Installation work could be slanted or front panel didn’t close properly.
Remote control/display does not work. Check whether batteries are correctly inserted or need replacement.
The unit cannot operate. Check either circuit breaker is tripped or timer is used correctly.
Outdoor unit emits water/steam. Condensation or evaporation happens at piping surface.
Air inlet (side)
QUIET
POWERFUL
ION
SUPER
ALLERU-BUSTER
TIMERPOWER
Air intake
Airflow direction
louver
Ionizer
Air filter
Front panel
Indoor Unit
Indicator
Supersonic air
purifying device
Auto OFF/ON
button
Receiver
Discharged air
Do not touch
during operation
LCD display
Off/On
Fan speed selection
Memory reset Clock setting
Temperature setting
Powerful operation
Operation mode
Quiet operation
Timer setting
Ion operation
Airflow direction
adjustment
Remote Control Transmitter
Check
About
Remote Control Preparation
Make sure it is not obstructed.
Maximum distances: 10m.
Certain fluorescent lights may
interfere with signal transmission.
Consult your dealer.
Remote Control Signal
To operate the unit if the
remote control is misplaced or
malfunctioning.
Action Operation
mode
Press once Automatic
Operation
Press until “beep”
sound and release.
Cooling
Operation
Press until “beep”
sound and release.
Press again until
“beep-beep” sound
and release.
Heating
Operation
To OFF, press again the Auto OFF/
ON button.
Auto OFF/ON Button
1. Pull out
2. Insert
batteries
(AAA or
R03)
5. Press again to confirm
Timer operation will be based on
current time set.
The batteries can be used for
approximately 1 year.
The batteries must be
recycled or disposed of
properly.
3. Press CLOCK button
4. Set
current
time

Produktspecifikationer

Varumärke: Panasonic
Kategori: Luftkonditionering
Modell: CS-E18DKEW

Behöver du hjälp?

Om du behöver hjälp med Panasonic CS-E18DKEW ställ en fråga nedan och andra användare kommer att svara dig




Luftkonditionering Panasonic Manualer

Luftkonditionering Manualer

Nyaste Luftkonditionering Manualer