Panduit FOCRX06Y Bruksanvisning

Läs nedan 📖 manual på svenska för Panduit FOCRX06Y (22 sidor) i kategorin Kablar för PC och kringutrustning. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/22
Fiber Optic
Cabling
Infrastructure
Offering
Visit www.panduit.com for more information.
High-Speed Fiber Cabling Systems
Panduit provides high bandwidth and mission-critical physical infrastructures in data center, enterprise, and campus networks with
comprehensive fiber optic systems that deliver high performance, reliability, and scalability. The deployment of high-speed cabling
systems has been increasing rapidly as data centers enable their physical infrastructure with 10 Gb/s capacity to support server
virtualization, I/O consolidation, and convergence of backbone applications.
2
Structured Cabling Infrastructure
A properly designed and implemented cabling infrastructure is a fundamental asset of every business. Carefully planning a
structured cabling solution facilitates the delivery of new services, lowers network maintenance costs, and increases productivity.
New high-bandwidth applications enable organizations to better fulfill their need for productivity and innovation in a rapidly
changing world.
Innovative Data Center Infrastructure Solutions
Panduit provides a comprehensive, intelligent data center offering that supports best practice methodologies. Our data center
solutions enable physical to logical architecture integration, and deliver robust, scalable physical infrastructures that address:
• Visibilityandcontrolformanagingandautomatingreal-timedataprocessesanddocumentation
• Convergenceofnewtechnologiesandhigh-speeddataapplications
• OperationalefciencythroughprocessimprovementandITinitiatives,suchascoolingconservation
through energy efficient data cabinets
• Capacitymanagementforgreaterrealestateutilization
• Modularpodsdesignedtosupporthigh-densityapplicationsandprovideconsistent,reliabledeploymentswhilelowering
infrastructure risk and costs
Panduit’s intelligent data center solutions facilitate faster implementation and simple specification, streamlining the process of
designing, specifying, installing, and managing the increasingly complex physical infrastructure necessary to optimize your data
center. Panduit knows the data center space intimately. We help you discover tangible infrastructure and business process
improvements that increase functionality, interoperability, and manageability of mission-critical operations across your
entire organization.
High Speed Data Transport Solutions
High Speed Data Transport (HSDT) Solutions are a set of complementary copper and optical fiber technologies for mission critical
data center applications, spanning storage and compute requirements and leading edge architectures. Based on an understanding
of today’s vital business and technology challenges and how they impact data centers, Panduit has created best-in-class physical
infrastructure solutions for HSDT. Panduit provides the broadest offering of end-to-end HSDT solutions supporting all data center
architectures. Designed for high-density/high-speed applications, Panduit HSDT solutions are backed by comprehensive research
and development programs to ensure high network performance, systems reliability, energy efficiencies, and seamless integration.
PanNet ® System Warranty
All Panduit channels are field tested by Panduit Certified Installers (PCI) using industry standard hand-held devices which provide
verified network performance, and ensures your network operates at optimal performance.
Panduit
®
Opti-Core
®
Fiber Optic Cable
3
Cable Fire Ratings Reference Guide
Cable fire ratings need to be considered when specifying cabling infrastructure to ensure local building codes are met. The below
rating guide provides the information needed to determine which rating is appropriate for different installation environments.
Plenum Rated Cable (OFNP)
A Plenum Rating (OFNP) signifies cable that has passed stringent burn testing and is suitable for installation into air plenum
spaces. OFNP cables have fire-resistance and low smoke production characteristics. They can be installed in ducts, plenums, and
other spaces used for building airflow. This is the highest fire rating fiber cable and no other cable types can be used as substitutes.
Plenum Rated Cable (OFCP)
A Plenum Rating (OFCP) differs from OFNP in that the cable contains metallic elements and, therefore, conducts electricity.
All other aspects of this rating are the same as OFNP.
Riser Rated Cable (OFNR)
A Riser Rating (OFNR) is commonly required when cables are run between floors through open vertical shafts. OFNR cables are
used in Riser areas which are building vertical shafts or runs from one floor to another floor. OFNR cables cannot be installed in
plenum areas since they do not have the required smoke rating as plenum rated cables. OFNP plenum cables can be used as
substitutes for OFNR Riser cables.
Riser Rated Cable (OFCR)
A Riser Rating (OFCR) differs from OFNR in that the cable contains metallic elements and, therefore, conducts electricity.
All other aspects of this rating are the same as OFNR.
Low Smoke Zero Halogen (LSZH)
ALowSmokeZeroHalogenRating(LSZH)issometimesreferredtoaslowtoxicitycable.Whenburned,PVC-basedcables
produce a cloud of toxic smoke containing corrosive compounds such as hydrochloric acid. The LSZH cables do not contain the
Halogen type compounds that form these toxic substances. Smoke emitted from burning LSZH cables do not produce the toxic
halogen-based gasses previously mentioned.
Non-Flame Rated
Outside Plant (OSP) cables are intended for outdoor use only. Typically, these cables are constructed using varying densities of
Polyethylene, (PE) in the outer jacket, and perhaps in other OSP cable components. Because cables without flame ratings do not
contain flame suppressants and emit noxious gasses when burned, building codes often restrict the distance installers are
permitted to route inside buildings before termination.
Panduit
®
Opti-Core
®
Fiber Optic Cable
Visit www.panduit.com for more information.4
Fiber Cable for Americas
(North America and Latin America)
1
F
2
S
3
P
4
D
5
5
6
1
7
2
8
9
0
10
5
11
0
12
M
1 and 2 Fiber Product
FS = Fiber
3 Cable Construction
P = Dielectric conduited
distribution (indoor)
4 Flame/Smoke Rating
D = Dual Rated Riser (OFNR)
and Low Smoke
Zero Halogen
5 Fiber Type
6 = OM1 62.5/125µm
5 = OM2 50/125µm
9 = OS2 9/125µm
6 and 7 Fiber Count
02 = 2-fiber
04 = 4-fiber
08 = 8-fiber
12 = 12-fiber
8 Dash
Blank 1km fixed reel
9, 10, 11, and 12 Reel Length
050M = 50-meter fixed reel
Character
Example
Cable Outer
Jacket
Aramid
Strength
Members
Optical Fiber
Buffer
Dielectric
Conduit
Opti-Core ® Dielectric Conduited Fiber (DCF) Optic Cable
For indoor use in intra-building backbone and horizontal installations.
Opti-Core ® Indoor Interlocking Armored Cable
Used in intrabuilding backbone, building backbone, and horizontal
installations and harsh environments.
1
F
2
O
3
P
4
R
5
Z
6
0
7
6
8
Y
1 and 2 Fiber Product
FS = Fiber OM1, OM2, OS2
FO = Fiber OM3, OM4
3 Cable Construction
P = Interlocking aluminum
armored indoor
4 Flame/Smoke Rating
R = Riser (OFNR)
P = Plenum (OFNP)
5 Fiber Type
9 = OS2 9/125µm
6 = OM1 62.5/125µm
5 = OM2 50/125µm
X = OM3 10G 50/125µm
Z = OM4 10G 50/125µm
6 and 7 Fiber Count
06 = 6-fiber
12 = 12-fiber
24 = 24-fiber
36 = 36-fiber
48 = 48-fiber
72 = 72-fiber
96 = 96-fiber
1A = 144-fiber
8 RoHS
Y = RoHS compliant
Character
Example
Cable Outer Jacket
Strength
Members
Optical Fiber
Buffer
Overlaid Jacket
Aluminum
Interlocking Armor
5
Fiber Cable for Americas
(North America and Latin America)
Strength Members
Optical Fiber
Buffer
Outer Jacket
Opti-Core ® Indoor Distribution Cable
For indoor use in intra-building backbone and horizontal installations.
1
F
2
S
3
D
4
P
5
5
6
0
7
6
8
Y
1 and 2 Fiber Product
FS = Fiber OM1, OM2, OS2
FO = Fiber OM3, OM4
3 Cable Construction
D = Distribution cable
4 Flame/Smoke Rating
R = Riser (OFNR)
P = Plenum (OFNP)
5 Fiber Type
9 = OS2 9/125µm
6 = OM1 62.5/125µm
5 = OM2 50/125µm
X = OM3 10G 50/125µm
Z = OM4 10G 50/125µm
6 and 7 Fiber Count
06 = 6-fiber
12 = 12-fiber
24 = 24-fiber
36 = 36-fiber
48 = 48-fiber
72 = 72-fiber
8 RoHS
Y = RoHS Compliant
Character
Example
Opti-Core ® IndustrialNet Polymer Coated Fiber (PCF) Fiber Optic Cable
Interconnect
Used for in-cabinet applications demanding high mechanical
performance; quick and easy to terminate.
1
F
2
I
3
I
4
D
5
1
6
0
7
2
8
9
0
10
2
11
5
12
M
1 Fiber Product
F = Fiber
2 Product Type
I = Opti-Core® IndustrialNet
PCF Cable
3 Cable Construction
I = Interconnect cable
(duplex zipcord)
4 Flame/Smoke Rating
D = Dual Rated Riser (OFNR)
and Low Smoke Zero
Halogen (LSZH)
5 Fiber Type
1 = 62.5/200/230
graded-index polymer
coated fiber
2 = 50/200/230 graded-index
polymer coated fiber
6 and 7 Fiber Count
02 = 2-fiber
8 Dash
Blank Length made to order
9, 10, 11 and 12 Reel Length
025M 25-meter fixed reel
Character
Example
Outer Jacket 500µm ETFE Buffer
Optical Fiber
Visit www.panduit.com for more information.6
Twin-70 Profile Raceway
1
F
2
S
3
L
4
P
5
5
6
1
7
2
1 and 2 Fiber Product
FS = Fiber OM1, OM2, OS2
FO = Fiber OM3 and OM4
3 Cable Construction
L = Indoor/Outdoor Tight
Buffered Armored
4 Flame Rating
R = Riser
P = Plenum
5 Fiber Type
9 = OS2 9/125µm
6 = OM1 62.5/125µm
5 = OM2 50/125µm
X = OM3 10G 50/125µm
Z = OM4 10G 50/125µm
6 and 7 Fiber Count
02 = 2-fiber
04 = 4-fiber
06 = 6-fiber
08 = 8-fiber
12 = 12-fiber
24 = 24-fiber
36 = 36-fiber
48 = 48-fiber
72 = 72-fiber
96 = 96-fiber
1A = 144-fiber (Riser only)
Character
Example
Cable Outer
Jacket
Strength
Members
Optical Fiber
Buffer
Overlaid Jacket
Opti-Core ® Indoor/Outdoor Interlocking Armored Cable with Tight Buffered Fibers
For use indoors and outdoors. Interlocking aluminum armor
eliminates the need for inner duct or conduit.
Opti-Core ® All-Dielectric Indoor/Outdoor Cable with Tight Buffered Fibers
These cables provide an effective solution for inter-building and
building transition applications.
1
F
2
S
3
K
4
R
5
5
6
1
7
2
1 and 2 Fiber Product
FS = Fiber OM1, OM2, OS2
FO = Fiber OM3, OM4
3 Cable Construction
K = Indoor/Outdoor Tight
Buffered Unarmored
4 Flame/Smoke Rating
R = Riser
P = Plenum
5 Fiber Type
9 = OS2 9/125µm
6 = OM1 6.25//125µm
5 = OM2 50/125µm
X = OM3 10G 50/125µm
Z = OM4 10G 50/125µm
6 and 7 Fiber Count
02 = 2-fiber
04 = 4-fiber
06 = 6-fiber
08 = 8-fiber
12 = 12-fiber
24 = 24-fiber
36 = 36-fiber
48 = 48-fiber
72 = 72-fiber
96 = 96-fiber
1A = 144-fiber (Riser only)
Character
Example
Outer Jacket
Aramid
Strength
Members
Optical Fiber
Buffer
Fiber Cable for Americas
(North America and Latin America)
Aluminum
Interlocking
Armor

Produktspecifikationer

Varumärke: Panduit
Kategori: Kablar för PC och kringutrustning
Modell: FOCRX06Y

Behöver du hjälp?

Om du behöver hjälp med Panduit FOCRX06Y ställ en fråga nedan och andra användare kommer att svara dig




Kablar för PC och kringutrustning Panduit Manualer

Kablar för PC och kringutrustning Manualer

Nyaste Kablar för PC och kringutrustning Manualer