5GHz 14dBi High Gain Dual Polarization Directional Antenna
ANT-FP14AD
Installation Guide
1. Package Contents
ANT-FP14AD x 1 unit
Accessory (including screws and brackets) x 1 set
2.Specications
Electrical Specications
Frequency Range 5.15 ~ 5.85GHz
Max. Gain 14dBi
Antenna Type Uni-directional, Flat Panel
V.S.W.R. <1.5
Polarization Horizontal and Vertical (Dual Polarization)
HPBW / Horizontal 30 degrees
HPBW / Vertical 30 degrees
Input Impedance 50Ω
Connector N-Type (Female) x 2
Environment & Mechanical Characteristics
Survival Wind Speed Greater than 150MPH
Radome Color Gray-white
Radome Material ABS, UV resistant
Dimensions (W x D x H) 228 x 15 x 228mm (Connector excluded)
Weight 550g
Weatherproof IP55
Mount Type Pole Mount
Outlook:
228
228
15
3.MountingConguration
up
OUTDOOR INSTALLATION WARNING
IMPORTANT SAFETY PRECAUTIONS:
LIVES MAY BE AT RISK! Carefully observe these instructions and any special instructions that are included with the
equipment you are installing.
CONTACTING POWER LINES CAN BE LETHAL.
Make sure no power lines are anywhere where possible contact can be made. Antennas, masts,
towers, guy wires or cables may lean or fall and contact these limes. People may be injured or
killed if they are touching or holding any part of equipment when it contacts electrical lines. Make
sure there is NO possibility that equipment or personnel can come in contact directly or indirectly
with power lines. Assume all overhead lines are power lines. The horizontal distance from a tower,
mast or antenna to the nearest power line should be at least twice the total length of the mast/
antenna combination. This will ensure that the mast will not contact power if it falls either during
installation or later.
TO AVOID FALLING, USE SAFE PROCEDURES WHEN WORKING AT HEIGHTS
ABOVE GROUND.
Select equipment locations that will allow safe, simple equipment installation.
Dont work alone. A friend or co-worker can save your life if an accident happens.
Use approved non-conducting lasers and other safety equipment. Make sure all equipment is in good repair.
If a tower or mast begins falling, don’t attempt to catch it. Stand back and let it fall.
If anything such as a wire or mast does come in contact with a power line, DON’T TOUCH IT OR ATTEMPT TO MOVE IT.
Instead, save your life by calling the power company.
Dont attempt to erect antennas or towers on windy days.
MAKE SURE ALL TOWERS AND MASTS ARE SECURELY GROUNDED, AND ELECTRICAL CABLES CONNECTED TO ANTENNAS
HAVE LIGHTNING ARRESTORS. This will help prevent re damage or human injury in case of lightning, static build-up, or short
circuit within equipment connected to the antenna.
The base of the antenna mast or tower must be connected directly to the building protective ground or to one or more approved
grounding rods, using 1 OAWG ground wire and corrosion-resistant connectors.
Refer to the National Electrical Code for grounding details.
IF A PERSON COMES IN CONTACT WITH ELECTRICAL POWER, AND CANNOT MOVE:
DON’T TOUCH THAT PERSON, OR YOU MAY BE ELECTROCUTED.
Use a non-conductive dry board, stick or rope to push or drag them so they no longer are in contact with electrical power.
Once they are no longer contacting electrical power, administer CPR if you are certied, and make sure that emergency medical aid
has been requested.
Part No: 2011-E30310-000