RCBS 98914 Bruksanvisning

Läs nedan 📖 manual på svenska för RCBS 98914 (4 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/4
USER MANUAL
Thank you for purchasing the RCBS Digital Pocket Scale.
Please read all operating instructions carefully prior to
use. This electronic scale is a precision instrument, and will
provide years of reliable service. Never load the scale with
more than the maximum load capacity of 100 grams or 1500
grains. Overloading will permanently damage the scale.
Avoid any exposure to extreme heat or cold, your scale works
better when operated at normal room temperature. Always
allow the scale to acclimate to normal room temperature and
allow for sucient warm up time prior to calibration. This is
done to ensure the internal components have stabilized and
reached thermal equilibrium. 30 minutes will be a sucient
warm up period.
Keep your scale in a clean environment, free of dust, dirt and
moisture. Be aware of vibration and air currents as this can
also aect the scales performance. Maintain an adequate
distance from other electronic devices as some electronics
can cause an electrical disturbance which can also aect
the scales accuracy. Handle with care and apply all items to
be weighed directly onto the platform or in the provided
scale pan. This scale is built for its durability; however, try to
avoid unnecessary rough handling as this may permanently
damage the load cell.
Avoid shaking, dropping or otherwise shocking the scale. This
is a precision instrument and must be handled with extreme
care.
ONLY OPERATE THE SCALE ON A STABLE, VIBRATION FREE
SURFACE.
Prior to use, turn on scale by pressing the “ON/OFF” key.
Place the calibration weight onto the platform and allow
unit to warm up for 30 minutes prior to use.
CALIBRATION
1. Place scale on a at surface.
2. Press “ON/OFF” key to turn the scale on.
3. When “0.0” or “0.000” is displayed, press and hold the
“MODE” key until “CAL is displayed
4. Press the “MODE” key again, “50.00g” will ash.
5. Place the 50 gram Calibration weight onto the center of
the platform.
6. Leave the calibration weight on the platform until PASS”
is displayed.
7. Remove calibration weight.
8. Scale will return to zero.
OPERATION
1. Use scale only after successful completion of calibration.
2. Use the “MODE” key to select the desired units of
measure; Grams (g) or Grains (gn).
3. Place the scale pan onto the platform and press the
TARE” key. This will tare out the scale pan, so objects
can be placed inside of the scale pan for weighing.
4. If the scale pan is not being used, press the “TARE” with
nothing on the platform, this will allow for placing
objects directly onto the platen for weighing.
It is good practice to periodically check the scale by placing
the calibration weight onto the platen. If the displayed weight
is o by more than +/- .01 g or .1 gn. ; re-calibrate the scale.
98914 Pocket Scale
IMPORTANT: PLEASE READ ALL INFORMATION FIRST
Like any scale, you control the accuracy of your RCBS® Digital Mini-Scale. Before using
the scale, read this instruction manual carefully to fully learn how to safely operate
the scale. Failure to properly operate the scale can result in severe personal injury
and/or equipment damage. If you have read these instructions and still do not
understand some operation, call us at 1-800-379-1732 and a technician will assist you.
This instruction manual contains specic safety and operating information. It should
be considered a permanent part of your reloading equipment and remain with the
equipment at all times for easy reference.
RELOADING SAFETY
Reloading is an enjoyable and rewarding hobby that can be conducted safely. However,
as with any hobby, carelessness or negligence can make reloading hazardous. This
product has been designed from the beginning with the user’s safety in mind. When
reloading, safety rules must be followed. By observing these rules, the chance of a
hazardous occurrence causing personal injury or property damage is minimized.
GENERAL
Always wear safety glasses.
Understand what you are doing and why. Read handbooks and manuals on
reloading. Talk to experienced reloaders. Write or call suppliers of equipment or
components if you have questions or are in doubt.
Read and understand all warnings and instructions accompanying your
equipment and components. If you do not have written instructions, request a
copy from the manufacturer. Keep instructions for future reference.
Do not rush or take short cuts. Establish a routine and follow it at a leisurely
pace.
Do not smoke while reloading, or reload near sources of heat, sparks or ame.
Observe good housekeeping in the reloading area. Keep tools and components
neat, clean and orderly. Promptly and completely clean up any spills.
Keep your hands and ngers away from “danger” spots and pinch-points where
they might be injured.
Keep all reloading equipment and components out of reach of children.
Keep all packing material out of reach of children.
This device is not intended for use by individuals with restricted physical,
sensory or mental capacities or those with a lack of experience and/or
knowledge, including children, unless they are supervised by an individual who
is responsible for their safety or have received training in operating the device.
Stay alert. Reload only when you can give your undivided attention. Do not
reload when tired, ill, rushed or under the inuence of drugs or alcohol.
Because RCBS® has no control over the choice, assembly or use of components or other
reloading equipment, RCBS assumes no liability, expressed or implied, for the use of
ammunition reloaded with this product.
POWDER
Store powder beyond the reach of children and away from heat, dampness,
open ames and electrical equipment. Avoid areas where static electricity is
evident.
DO NOT have more than one can of powder on the bench at one time. Powder
cans should be stored away from the bench to avoid picking up the wrong one.
DO NOT use any powder unless its identity is positively known. The only
positive identication is the manufacturer’s label on the original canister.
Discard all mixed powders and those of uncertain identity.
LOADING DATA
WARNING! DO NOT SMOKE WHILE RELOADING.
OBSERVE ALL WARNINGS ABOUT THE USE OF MAXIMUM LISTED LOADS.
Use only laboratory tested reloading data. We recommend the SPEER
Reloading Manual.
WARNING!
This digital scale is for use with smokeless powders only. DO NOT USE WITH BLACK
POWDER (used in muzzle loading rearms). If black powder should come in contact with
an electrical spark, an explosion may occur, resulting in serious injury or death.
WARNING!
Before using this product, read and follow these instructions
carefully. Failure to do so could result in serious injury or
death, or property damage.
If you have any questions while assembling
or operating this product,
call us at 1-800-533-5000 (U.S. or Canada)
Monday – Friday 5:00 a.m. – 5:00 p.m. Pacic Time
Or email us at rcbs.tech@vistaoutdoor.com
This manual contains important safety and operating
information. Keep this as a permanent part of your reloading
equipment. If lost, contact us for a replacement.
SPECIFICATIONS
Capacity: 1500 grains (100.0 grams), Accuracy: 0.1 grain (0.01 gram)
Units: gn (grain), g (gram)
Power: 2 AAA batteries
Platform Size: 2.95 x 2.36 inches (75x60mm)
CALIBRATION
Calibration should be performed before every use. To calibrate correctly, follow the
CALIBRATION section of this instruction manual. A scale with improper calibration will
cause an incorrect charge weight which may exceed the maximum recommended load.
Re-check frequently during use with the calibration weight provided. If accuracy is found
to be out of tolerance, the scale must be recalibrated.
PRECAUTIONS
Digital scales are very reliable devices. However, there are some events which may result
in an inaccurate reading:
Change in temperature. If the temperature changes more than a few degrees,
you must re-calibrate the scale. Allow scale to stabilize for 20-30 minutes prior
to use.
Changes in scale location or a non-level working surface.
O center placement of weights on the platen.
Jarring of the scale during operation.
Use only the calibration weight supplied for accuracy.
Weight accuracy is crucial. Keep weights clean and carefully stored. If dropped
or damaged, have weights inspected against known standards. Contact RCBS
Customer Service.
Static electricity can cause the scale to “jump around”. If static build-up is
evident, wipe scale with an anti-static sheet, or use anti-static spray. Spray on
clean soft cloth rst. Do not allow spray to get into mechanism.
If powder should get inside the unit, stop operation immediately and do not
use scale until it has been serviced. Contact RCBS Customer Service.
Do not press on the platform with your hand. You can damage the scale.
RECORD KEEPING
Keep complete records of reloads. Apply a descriptive label to each box
showing the date produced, and the primer, powder and bullet used. Labels
for this purpose are packed with SPEER® bullets. Never attempt to guess at the
identity of your ammunition.
ONE YEAR LIMITED WARRANTY
Congratulations on the purchase of your new RCBS Pocket Scale. Your new Pocket Scale is warranted to be free
from defects in material or workmanship for a period of one (1) year from the date of purchase. This warranty
is extended only to the original consumer purchaser. Should you believe that your Pocket Scale is defective in
material or workmanship, you must return it to RCBS, postage paid, for evaluation. If defective, the product will
be repaired or replaced at RCBS’s option, at no charge .
Send a check in the amount of ten dollars ($10) U.S. payable to RCBS Operation for return shipping and handling,
along with the unit to: RCBS
605 Oro Dam Blvd East
Oroville, California 95965
Warranty services cannot be provided without meeting the above requirements.
THIS WARRANTY DOES NOT COVER DEFECTS OR DAMAGE RESULTING FROM: CARELESSNESS, MISUSE, IMPROPER
INSTALLATION, MODIFICATION, OR IF YOUR POCKET SCALE HAS BEEN ALTERED OR REPAIRED BY ANYONE OTHER
THAN FACTORY PERSONNEL.
WARRANTY SERVICES CANNOT BE PROVIDED WITHOUT MEETING THE ABOVE REQUIREMENTS.
Please retain this warranty certicate for future reference.
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO
THE DURATION OF THIS LIMITED WARRANTY. RCBS OPERATION IS NOT LIABLE FOR DAMAGES IN EXCESS OF THE
PURCHASE PRICE OF THE PRODUCT AND UNDER NO CIRCUMSTANCES SHALL RCBS OPERATION BE LIABLE FOR
CONSEQUENTIAL OR INCIDENTAL DAMAGES. HOWEVER, SOME STATES DO NOT ALLOW LIMITATIONS ON INCIDENTAL
OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
The above warranty provides the sole and exclusive warranty available to the customer in the event of a defect in
material or workmanship in the Pocket Scale. This warranty gives you specic legal rights, and you may also have
other rights which vary from state to state.
NOTE: This instrument may only be serviced by a certied technician. See back cover for
address and Toll-free Customer Service phone number.

Produktspecifikationer

Varumärke: RCBS
Kategori: Inte kategoriserad
Modell: 98914

Behöver du hjälp?

Om du behöver hjälp med RCBS 98914 ställ en fråga nedan och andra användare kommer att svara dig




Inte kategoriserad RCBS Manualer

Inte kategoriserad Manualer

Nyaste Inte kategoriserad Manualer