Samsung AC100KX4DKH/EU Bruksanvisning
Läs nedan 📖 manual på svenska för Samsung AC100KX4DKH/EU (48 sidor) i kategorin Värmepump. Denna guide var användbar för 10 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/48
Air conditioner
Installation manual
AC777KX4D7H
ŷThank you for purchasing this Samsung air conditioner.
ŷBefore operating this unit, please read this manual carefully and retain it for future
reference.
2English
Contents
For information on Samsung’s environmental commitments and product-specific regulatory obligations, e.g. REACH,
WEEE, Batteries, visit : samsung.com/uk/aboutsamsung/samsungelectronics/corporatecitizenship/data_corner.html
Safety Information 3
General information 3
Installing the unit 4
Power supply line, fuse or circuit breaker 4
Installation Procedure 5
Step 1 Choosing the installation location 5
Step 2 Fixing the outdoor unit in place 7
Step 3 Connecting the power cables, communication cable, and controllers 8
Step 4 Optional: Extending the power cable 14
Step 5 Connecting the refrigerant pipe 16
Step 6 Optional: Cutting and flaring the pipes 17
Step 7 Installing oil traps 18
Step 8 Connecting up and removing air in the circuit 18
Step 9 Adding refrigerant (R-410A) 19
Step 10 Performing the gas leak test 21
Step 11 Connecting the drain hose to the outdoor unit 21
Step 12
Insulating the refrigerant pipes 22
Step 13 Checking the earthing 23
Step 14 Performing final check and trial operation 23
Extra procedures 27
Pumping down refrigerant 27
Relocating the indoor and outdoor units 27
Using the stop valve 27
Appendix 29
Troubleshooting 29
Technical specifications 31
COMMISSION DELEGATED REGULATION (EU) No 626/2011i) 32
3English
Safety Information
WARNING
ŷ Hazards or unsafe practices that may result in severe
personal injury or death.
CAUTION
ŷ Hazards or unsafe practices that may result in minor
personal injury or property damage.
Carefully follow the precautions listed below because
they are essential to guarantee the safety of the
equipment.
WARNING
ŷ Always disconnect the air conditioner from the power
supply before servicing it or accessing its internal
components.
ŷ Verify that installation and testing operations are
performed by qualified personnel.
ŷ Verify that the air conditioner is not installed in an
easily accessible area.
General information
WARNING
ŷ Carefully read the content of this manual before
installing the air conditioner and store the manual in
a safe place in order to be able to use it as reference
after installation.
ŷ For maximum safety, installers should always
carefully read the following warnings.
ŷ Store the operation and installation manual in a safe
location and remember to hand it over to the new
owner if the air conditioner is sold or transferred.
ŷ This manual explains how to install an indoor unit
with a split system with two SAMSUNG units. The use
of other types of units with different control systems
may damage the units and invalidate the warranty.
The manufacturer shall not be responsible for
damages arising from the use of non compliant units.
ŷ This product has been determined to be in compliance
with the Low Voltage Directive (2006/95/EC), and the
Electromagnetic Compatibility Directive (2004/108/
EC) and the Machinery Directive (2006/42/EC) of the
European Union.
ŷ The manufacturer shall not be responsible for damage
originating from unauthorized changes or the
improper connection of electric and requirements set
forth in the “Operating limits” table, included in the
manual, shall immediately invalidate the warranty.
ŷ The air conditioner should be used only for the
applications for which it has been designed: the
indoor unit is not suitable to be installed in areas
used for laundry.
ŷ Do not use the units if damaged. If problems occur,
switch the unit off and disconnect it from the power
supply.
ŷ In order to prevent electric shocks, fires or injuries,
always stop the unit, disable the protection switch
and contact SAMSUNG’s technical support if the unit
produces smoke, if the power cable is hot or damaged
or if the unit is very noisy.
ŷ Always remember to inspect the unit, electric
connections, refrigerant tubes and protections
regularly. These operations should be performed by
qualified personnel only.
ŷ The unit contains moving parts, which should always
be kept out of the reach of children.
ŷ Do not attempt to repair, move, alter or reinstall the
unit. If performed by unauthorized personnel, these
operations may cause electric shocks or fires.
ŷ Do not place containers with liquids or other objects
on the unit.
ŷ All the materials used for the manufacture and
packaging of the air conditioner are recyclable.
ŷ The packing material and exhaust batteries of the
remote controller(optional) must be disposed of in
accordance with current laws.
ŷ The air conditioner contains a refrigerant that has
to be disposed of as special waste. At the end of its
life cycle, the air conditioner must be disposed of in
authorized centres or returned to the retailer so that
it can be disposed of correctly and safely.
Safety Information
Produktspecifikationer
Varumärke: | Samsung |
Kategori: | Värmepump |
Modell: | AC100KX4DKH/EU |
Behöver du hjälp?
Om du behöver hjälp med Samsung AC100KX4DKH/EU ställ en fråga nedan och andra användare kommer att svara dig
Värmepump Samsung Manualer
21 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
Värmepump Manualer
- Värmepump Electrolux
- Värmepump LG
- Värmepump Bosch
- Värmepump AEG
- Värmepump Grundig
- Värmepump Miele
- Värmepump Remeha
- Värmepump Siemens
- Värmepump Vaillant
- Värmepump Arcelik
- Värmepump Fisher And Paykel
- Värmepump Hisense
- Värmepump Westinghouse
- Värmepump Hotpoint
- Värmepump Blaupunkt
- Värmepump Balay
- Värmepump Mitsubishi
- Värmepump Elco
- Värmepump Dimplex
- Värmepump Nibe
- Värmepump Ferroli
- Värmepump Fujitsu
- Värmepump Wilfa
- Värmepump Carrier
- Värmepump Olimpia Splendid
- Värmepump Itho-Daalderop
- Värmepump Qlima
- Värmepump Atlantic
- Värmepump Tesy
- Värmepump AWB
- Värmepump Vivax
- Värmepump Maxicool
- Värmepump Astralpool
- Värmepump Baxi
- Värmepump Hydro-Pro
- Värmepump Fairland
- Värmepump Thermor
- Värmepump Armstrong
- Värmepump Flojet
- Värmepump Harmopool
- Värmepump JANDY
- Värmepump Grundfos
- Värmepump Kospel
- Värmepump Wilo
- Värmepump Waterco
Nyaste Värmepump Manualer
27 Oktober 2024
17 Oktober 2024
30 September 2024
30 September 2024
29 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
25 September 2024