Contents
· Selecting solderless ring terminal .................... 36
· Connecting the power terminal ....................... 36
· Installing grounding wire ..................................... 38
Air tightness test and vacuum drying 40 ...........................
· Air Tightness ................................................................ 40
· Vacuum drying pipes and indoor units ....... 41
Charging refrigerant 42 .............................................................
· Important information regulation regarding
the refrigerant used ................................................ 42
· Charging refrigerant .............................................. 43
Pipe insulation ......................................................................... 44
· Insulating the refrigerant pipes and branch
joints ................................................................................. 44
· Selecting the refrigerant pipe insulator 44 ......
· Insulate the refrigerant pipe .............................. 45
· Insulate the distribution header ..................... 46
· Insulating the pipe located inside of the
outdoor unit ................................................................ 47
Basic segment display .......................................................... 48
Setting outdoor unit option switch and key
function .....................................................................................49
· Setting outdoor unit key function ................. 49
· Setting key operation and checking the view
mode with tact switch ....................................... 54
Things to check after completing the installation .. 57
Inspection & test operation ................................................59
· Checklist before auto trial operation ............ 59
· Auto trial operation ................................................. 60
Inspection & trial operation ................................................61
Automatic refrigerant amount detection function
..........................................................................................................62
Safety precautions ..................................................................... 3
Preparations for Installation .................................................. 6
· Outdoor unit classication ...................................... 6
· Accessories ....................................................................... 6
· Optional accessories ................................................... 7
Selecting installation location .............................................. 7
· Space requirements ................................................. 10
· Moving the outdoor unit ........................................13
Basic construction and installation of the outdoor unit
.......................................................................................................... 14
· Installation of Outdoor unit ................................. 14
Installation of Air-conditioner 17 ...........................................
· Refrigerant pipe work 17 ..............................................
· Selecting refrigerant pipe ..................................... 18
· Keeping refrigerant pipe ........................................ 21
· Temper grade and minimum thickness of the
refrigerant pipe ........................................................... 21
· Refrigerant pipe welding and safety
information .................................................................... 22
· Cutting or aring the pipes ................................. 23
· Connecting the ared pipes ............................... 24
· Pipe installation for an outdoor unit ............. 25
· Connecting the drain hose to the outdoor unit .
............................................................................................. 26
· Examples of refrigerant pipe installation .... 27
· Allowable length of the refrigerant pipe and
the installation examples ...................................... 28
· Installation of refrigerant Y-joint ....................... 30
· Installation of the distribution header .......... 32
Wiring work 33 ................................................................................
· Specication of the circuit breaker and power
cable ................................................................................. 33
· Specication of the protection tube ............... 34
· Power wiring Diagram ............................................ 35
3
WARNING
Hazards or unsafe practices that may result in severe personal injury or death.
CAUTION
Hazards or unsafe practices that may result in minor personal injury (to installer/user) or
property damage.
SEVERE WARNING SIGNS
Consult qualied installer or dealer for installation.
When installation is done by unqualied person, problems such as water leakage, electric shock or re may occur.
Installation work must be done properly according to this installation manual.
When installation is not done properly, it may cause water leakage, electric shock or re.
When installing the unit in a small room, take measure to keep the refrigerant concentration from exceeding allowable
safety limits in case of refrigerant leakage. Consult the dealer for precautionary measure before the installation.
When refrigerant leaks and exceed dangerous concentration level, it may cause suffocation accidents.
If any gas or impurities, except R-410A refrigerant, come into the refrigerant pipe, serious problem may occur and it may
cause injury.
Use the supplied accessories, specied components and tools for the installation.
Do not use the pipe and the installation product used for the R-22 refrigerant.
Failure to use the specied components can cause product fall down, water leakage, electrical shock, and re. (The pipe
and are components used for R-22 refrigerant must not be used)
Install the outdoor unit on a hard and even place that can support its weight.
If the place cannot support its weight, the outdoor unit may fall down and it may cause injury.
This product has been determined to be in compliance with the Low Voltage Directive (2006/95/EC), the
Electromagnetic Compatibility Directive (2004/108/EC), the Pressure Equipment Directive (97/23/EC) and the
Machinery Directive (2006/42/EC) of the European Union.
Wear protective equipment (such as safety gloves, goggles, and headgear) during installation and maintenance works.
Installation/repair technicians may be injured if protective equipment is not properly equipped.
Safety precautions
Please follow the following safety information for safety of the installer and the user.
DVM S ECO air conditioner uses R-410A refrigerant.
When using R-410A, moisture or foreign substances may affect the performance and reliability of the product.
Safety precautions must be obeyed when installing the refrigerant pipe.
The designed maximum pressure of the system is 4.1MPa and therefore select appropriate material and thickness
according to the regulations.
R-410A is a quasi-azeotrope of two refrigerants and it has to be charged in liquid phase whenlling the refrigerant.
(If you charge vapor refrigerant, it may change the blend of the refrigerant and cause product malfunction.)
You must connect the indoor units for R-410A refrigerant. Refer to product catalog to nd out the models names
for connectable indoor units. (If you connect the indoor units that are not designed for R-410A, it cannot operated
normally.)
After completing the installation and trial operation, explain to the user how to use and maintain the product. Also,
hand over this installation manual so that it can be stored by the user.
Manufacturer is not responsible for the incidents occurred by improper installation. Installer is responsible for any
installation related claims from the user occurred by neglecting warnings and cautions stated in this manual. (Installer
will be responsible for any service charges that may occur)
Generally, system air conditioners should not be relocated after installation. But when it has to be relocated for
inevitable reasons, please contact Samsungs qualied dealers for system air conditioners.