Seiko S149 Bruksanvisning

Seiko Titta S149

Läs nedan 📖 manual på svenska för Seiko S149 (14 sidor) i kategorin Titta. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/14
S149
取扱説明書
INSTRUCTION
1.FEATURES
● Cal.S149issuitableformeasuring massivetimedate
inaroadrace,marathonrace,etc.
With theuseof thebuilt-in printer,the measured
timedatacanbe printedoutassoon astheyare
obtained.
Year,month,dateandtimewhenthemeasurementis
startedcanbeprintedout,andtherefore,itiseasytofile
andkeepthedata.
Anautostartfunctionisprovided.Bypresettingthe
timewhenthemeasurementisstarted,thestopwatch
startsmeasuringautomaticallyatthedesignatedtime.
Memoryrecallfunction……Upto300measurement
datacan bestored inmemory. Measurementdata
obtainedfromthestarttofinishofthemeasurement
isrecordedasablockwithouterasingthedatainthe
previousblock,andupto100blocksofdatacanbe
storedinmemory.
This functionisvery useful forseparately keeping
thedatameasuredatdifferenttimeanddate.
Besides,thestopwatch isequippedwithsuch
convenient functionsas ID No.functionuseful for
keepingthedataof individualusersseparately,and
memorycapacityindicatorandfastestlaptimerecall
functions.
Anantibacterialagentisappliedtothecasesurfaceof
thestopwatches.
*Itlosesitsantibacterialeffectgraduallyovertimeandthe
effectiveperiod differsdepending ontheconditions of
use.
● Usedwithoptionaldevices,thestopwatchcanperform
variousfunctions.
By connecting the stopwatch to SEIKO Digital
StopwatchCal. S143,etc., morethan twostopwatches
canstartmeasuring simultaneously at afixed time.
Therefore,itispossibletomeasurethetimeinaroadrace
ormarathonatdifferentcheckpointsmoreaccurately.
Connectedwith agrip switch(optional accessory),the
stopwatchcanbeoperatedmoreeasily.
Withthe useof apaper extension holder(optional
accessory),massivetimedata(approximately2,500data)
canbemeasuredsuccessivelyatatime.
SEIKODigital StopwatchCal.S149isatimemeasuringdevicethatcanrecordthe
measurements with the use of the built-in printer. In addition, used with the
stopwatchCal.S143oragripswitch,Cal.S149canperformvariousfunctions.
CONTENTS −
1.FEATURES ……………………………38
2.DISPLAYANDBUTTON/SWITCH
OPERATION ……………………………39
3.TIME/CALENDAR ……………………40
4.HOWTOUSETHE
STOPWATCH …………………………40
5.HOWTOUSETHEMEMORY
FUNCTION……………………………48
6.HOWTOPRINTOUT ………………53
7.HOWTOUSETHEAUTO
STARTFUNCTION …………………59
8.HOWTOINSERTBATTERIESINTO
THEPRINTER …………………………64
9.TIME・CALENDAR
SETTING ………………………………65
10.PRECAUTIONS ………………………68
11.REMARKSONTHE
BATTERIES……………………………71
12.REPLACEMENTOFTHELIQUID
CRYSTALPANEL …………………72
13.CAREOFYOURWATCH …………72
14.TROUBLESHOOTINGGUIDE ……73
15.SPECIFICATIONS …………………74
2.DISPLAYANDBUTTON/SWITCHOPERATION
Paperadvancingswitch:
Witheachpressoftheswitch,oneline
is advanced. The paper is advanced
continuously by keeping the switch
pressed.
Modeselectionbutton:
① Stopwatch mode (accumulated
elapsed time or lap time mea-
surementinprogressdisplay)
②Autostartsettingmode
③Time/calendarmode
Printmodeselectionswitch:
Splittimeandlaptimeare
printedout.
    cUpperposition
    dLowerposition
Splittimeisprintedout.
Readoutselectionbutton:
With each press of the button, the
measurement is displayed in 1/100
secondsandonesecondalternately.
LAP
SPLIT
SPLIT
Rollpapercover:
Settherollpaperinsidethe
cover.
Powerswitchforprinter
Locklever:Theleverlocksbutton○
Gripswitchselector
Whenthegripswitchisused.
        cUpperposition
        dLowerposition
    Whenthegripswitchisnotused.
EXT
▲
Button
A
Button
B
Start/stop
Split/lapreset
Stopwatchmode
Selectionofthedigits
tobeadjusted
Autostartsetting
andTime/Calendar
mode
Memoryrecallbutton:
With each press of the button,
the times stored in the memory
canberecalled.
Jackforautostart
Thejackisusedfortransferring
theautostarttime.
Jackforgripswitch:
The jack connects the
grip switch with the
stopwatch.
Thedevicefordata
transferisnotavail-
ablenow
BLOCK
F
E
SYSTEM STOPWATCH
300L APSPLI T M EMORY
POWER
ON
LOCK
LAP SPLIT
RESET
START
STOP
CLEAR
1/100 STOP.W A/S SET TIME
RECALL
STOP -W.A/ SS ETTI ME
Settingthedigits
REC ALL
BLOCK
ST OP
BAT T .
LAP
F
E
300L APSPLIT MEM ORY
LOCK
LAP SPLIT
RESET
START
STOP
CLEAR
1/100 STOP.W A/S SET TIME
RECALL
Button
(STOP.W)
STOP -W.A/ SS ETTI ME
REC ALL
BLOCK
ST OP
BAT T .
LAP
F
E
300L APSPLIT MEM ORY
LOCK
LAP SPLIT
RESET
START
STOP
CLEAR
1/100 STOP.W A/S SET TIME
RECALL
Readoutselectionbutton
Pressthereadoutselection
buttontoselectthedisplay.
STOP -W.A/ SS ETTI ME
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
Displayinthestopwatchmode
(Thethirdlinedisplayisaccumlatedelapsedtime,forexample)
Splittime
Laptime
Accumulated
elapsedtime
No.ofsplit
time/lap
Stopwatchmodemark
(Themarkindicatedthestopwatchfunctionisactivated.)
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
1second
display 1/100seconds
display
Witheachpressofthebutton,thedisplaychangesoverbetween
1secondand1/100secondalternately.
Beforeselectingthereadoutofthemeasurement,besuretoreset
thedigitsto"00".
Ifthedigitsareresetto"00"afterthemeasurementismadeinone
secondreadoutthedisplayautomaticallyreturnsto1/100seconds.
Press modeselection to setbutton① (STOP.W)
thestopwatchtotheStopwatchmode.
*Witheachpressofbutton① thethirdlinedisplaychanges
over between accumlated elapsed time and lap time
measurementinprogressalternately.
Select thereadout ofthemeasurement between
1/100secondsand1second.
3.TIME/CALENDAR 4.
HOWTOUSETHESTOPWATCH
Notesontheblockofdatainmemory
・The SEIKO Stopwatch Cal. S149 features a "Block Memory"
stopwatchoperationsystem. The dataobtainedfrom starttillfinish
ofaraceisrecordedasablockandstoredinmemory.
・Thetimeanddateofstartingthemeasurementofablockofdataare
automaticallystoredinmemory.
・Beforethemeasurementisstarted,theblocknumberisassignedto
theblockofdatatobemeasured.
・Upto300datacanbestoredinmemory.
・Ablockofdataincludesatleastthreedata.Ifmorethanoneblockis
used to store the data, the memory become full even before the
numberoflaptime/splittimemeasurements inmemory amountsto
300.
REC ALL
BLOCK
ST OP
BAT T .
LAP
F
E
300L APSPLIT MEM ORY
LOCK
LAP SPLIT
RESET
START
STOP
CLEAR
1/100 STOP.W A/S SET TIME
RECALL
Button
(TIME)
STOP -W.A/ SS ETTI ME
ID
RECALL
BLPOK
STOP
BATT.
LAP
Year
Month
Date
Time(10'8''56)
Time/calendarmodemark
*Timedisplayedinthe24-hourindication
Displayinthetime/calendarmode
Pressmodeselectionbutton③ (TIME) toset
thetimetotheTime/calendarmode.
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
LAP SPLIT
RESET
START
STOP
F
E
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
LAP SPLIT
RESET
START
STOP
F
E
SPLIT
RECALL
BLOCK
LAP
STOP
BATT.
LAP
LAP SPLIT
RESET
START
STOP
F
E
(Start)
(Resetto"00")
(Stop)
A
\
B
\
A
\
Start Finish
Thenewblocknumberforthenextmeasurement
isdisplayedwiththedigitsresetto"00".
Nowmeasurementstarts.(Usethebuttons ○
,
Standardmeasurement Pressthebuttonsinthefollowingorder:○
→○
→○

Produktspecifikationer

Varumärke: Seiko
Kategori: Titta
Modell: S149

Behöver du hjälp?

Om du behöver hjälp med Seiko S149 ställ en fråga nedan och andra användare kommer att svara dig




Titta Seiko Manualer

Seiko

Seiko 6R20 Bruksanvisning

7 Januari 2025
Seiko

Seiko 6N01 Bruksanvisning

7 Januari 2025
Seiko

Seiko 6N76 Bruksanvisning

26 September 2024
Seiko

Seiko 6N53 Bruksanvisning

26 September 2024
Seiko

Seiko 6N52 Bruksanvisning

26 September 2024
Seiko

Seiko 6G28 Bruksanvisning

26 September 2024
Seiko

Seiko 4N30 Bruksanvisning

26 September 2024
Seiko

Seiko 4227 Bruksanvisning

26 September 2024
Seiko

Seiko 6N32 Bruksanvisning

26 September 2024
Seiko

Seiko 6N42 Bruksanvisning

26 September 2024

Titta Manualer

Nyaste Titta Manualer