Important Instructions
Suggest using IGMP Gigabit switches
Do not mix up transmitter and receiver
before installation
Channel of each transmitter(TX) must be
unique, otherwise, the system could break
down (including transmitter, receiver, IGMP
switch etc.)
Product Features
1. Resolution supported up to 1080p @60Hz
2. Transmission distance up to 120 meters (CAT6)
3. Support IR pass back function to control the
source device from RX location
4. Oers scalable TX/RX matrix conguration,
allows up to 256 total units, limited to 100
transmitters, additional transmitter units (part#
CE-H23B11) and receiver units (part# CE-
H23C11) sold separately
5. Supports computer control software to select
and switch between source devices .
Package Contents
1. Transmitter unit
2. Receiver unit
3. User Guide
4. IR blaster extension cable
5. IR receiver extension cable
6. DC5V/2A power adapter (x2)
7. Remote control
8. 3 pin phoenix connector (x2)
9. Wall-mount kit (x2)
10. Screws (x8)
Layout
Transmitter unit
OUTPUT GND RX TX
RS-232
1. IR window: remote control channel
2. Power indicator
3. TX ID: Indicator of the current TX’s number
4. Reset button
5. DC 5V/2A power jack
6. Data transmission indicator
7. RJ45 output
8. Connection indicator
9. IR blaster extension cable interface
10. HDMI local signal output
11. HDMI signal input
12. RS-232 connector
Receiver unit
G ND RX TX
RS-232
1. RX ID: Mark receiver unit as a number,
Indicator of the current RX’s number
2. IR window: remote control channel
3. Power indicator
4. TX connected: Indicator the input channel
as a number, and when the cahannel of
receiver as same as the channel of trans
mitter, transmission connected
5. Reset button
6. DC 5V/2A power jack
7. Data transmission indicator
8. RJ45 input
9. Connection indicator
10. IR receiver extension cable interface
11. HDMI signal output
12. RS-232 connector
Application
Point to point
R
J
-
45
O
UT
OUTP UT
R
S
-
2
3
2
G
N
D
R
X
T
X
RJ45
I
N
RS
-
23 2
GND
RX
TX
Matrix conguration
Note: Dedicated LANs with IGMP Gigabit Ethernet switches are
recommended for reliable performance. Installing on mixed LANs
may adversly eect performance is not supported.
RS232 bi-direction function
Baud rate
Different encoding mechanism can not mix-
connected, the baud rate of RS232 serial of these
transmitter unit and receiver unit, support 2400,
4800, 9600, 19200, 28800, 38400, 57600, and
115200
If the RS232 serial does not work by above con-
nection, please try to change the order of TXD
line and RXD line.
Check baud rate:
I f y o u n e e d t o c h e c k t h e b a u d r a t e .
Before powering on, set the baud rate to
115200 on your seria l port test tool and
power on. When the RS232 serial of the product
co n n ec te d to se ri a l po rt te s t to o l , th e
s o f t w a r e w i l l r e a d o u t t h e b a u d r a te .
E.g.: The software shows information Baud rate:
9600”, and it means 9600 is the current baud rate.
Set baud rate
For example, the current baud rate of extenders
are 9600, but the baud rate of control equipment
is 19200. In this case, choose baud rate 9600 for
serial port tool, then input command “set: 19200”
in character format and send it out. (set: xxxxx
have to send all at once in command line)
IR use guide
IR passback
IR blaster cable should be pluged into the IR-out
of Transmitter, and the IR receiver cable should
be pluged into the IR-in port of the Receiver. The
emitter of IR blaster cable should be as close as
possible to the IR receiver window of the signal
source device.
IR remote control
Using the IR remote controll to set/select the
channel of this HDMI Extender.
Button control
The left button controls the value of the left
Nixie tube, and the right one to control the value
of the right Nixie tube. When the value of TX
connected” on the RX unit matches the value of
TX ID” on the TX unit, the devices will pair/link
successfully.
Reset device to default
TX ID on TX unit and TX connected on the RX
unit. Press both buttons simultaneously and hold
them down for 3 seconds to reset to default.
Computer control software (Windows)
1. HDbitT E-Matrix Download software
Control center“ from http://www.hdbitt.
com/download-matrix/
2. Set PC’s IP to 192.168.1.xxx, then connect
your PC to the Ethernet switch which has
the same subnet with TX and RX units.
3. Open the software HDbitT E-Matrix Control
center and scan for devices.
IP setting
TX and RX have their own default IP address, TX’s
IP is 192.168.1.238, and RXs IP is 192.168.1.239.
Generally, there is no need to change the device
IP address, as the system can work normally
even though multiple TX units and multiple RX
units connected into the LAN have the same IP
address.
If IP change is required, follow the instructions on
the next page.
Device setting
Set device name, ID, Channel then click "Update"
button to save conguration
Pre-operation mode setting
Support
For more info or tech support
http://www.siig.com/support
April, 2018 Copyright © 2018 by SIIG, Inc. All rights reserved.
HDMI Over IP Extender with IR
User Guide
04-1129A
Operation mode selection setting
Click “Select Mode button and choose the mode
needed, then click "Update" button
Wireless Control APP
Requires installing a wireless access point on your
dedicated IGMP LAN.
Download the Android or Apple wireless APP at
www.hdbitt.com/download-matrix
Connect to the wireless access point which has
the same subnet as the TX and RX units
TX ID, RX ID, TX connected number can be
reset by this APP, along with editing the device
name

Produktspecifikationer

Varumärke: SIIG
Kategori: AV extender
Modell: CE-H23B11-S1

Behöver du hjälp?

Om du behöver hjälp med SIIG CE-H23B11-S1 ställ en fråga nedan och andra användare kommer att svara dig




AV extender SIIG Manualer

AV extender Manualer

Nyaste AV extender Manualer