Supermicro SuperServer 6028TP-HC1TR Bruksanvisning
Supermicro
Server
SuperServer 6028TP-HC1TR
Läs nedan 📖 manual på svenska för Supermicro SuperServer 6028TP-HC1TR (1 sidor) i kategorin Server. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/1
http://www.supermicro.com MNL-1664-QRG
Board Layout
SuperServer 6028TP-HC1R/HC1TR/HC1FR Quick Reference Guide
Rear View
BIOS Beep Codes
Beep Code/LED Message Description
1 beep Refresh Circuits have been reset.
(Ready to power up)
5 short beeps + 1 long
beep
Memory Error
5 beeps and 2 short
beeps
Display memory
read/write error
CPU Installation
Beep Codes
Front view & Interface
Heatsink Installation
1. Place the heatsink on top of the installed CPU.
2. Align the four screws to the socket.
3. Holding the heatsink in place, screw down as shown
(cross pattern, in order: A, C, B, D).
4. Note: Only use 6-8 lb/f of torque; otherwise, hand-tighten
each screw to avoid damaging the CPU.
Memory
Caution
SAFETY INFORMATION
IMPORTANT: See installation instructions and safety warning
before connecting system to power supply.
http://www.supermicro.com/about/policies/safety_information.cfm
WARNING
To reduce risk of electric shock/damage to equipment,
disconnect power from server by disconnecting all power
cords from electrical outlets.
If any CPU socket empty, install protective plastic CPU cap
CAUTION
Always be sure all power supplies for this system have
the same power output. If mixed power supplies are
installed, the system will not operate.
Align CPU to socket;
install CPU straight down
For more information go to :
http://www.supermicro.com/support
!
!
No memory detected
NOTE:
Do not bend pin inside socket
!
!
Processors and Memory Module Population for Optimal Performance
Number of
CPUs + DIMMs
CPU and Memory Population Configuration Table
(For memory to work properly, follow the instructions below)
1 CPU & 2 DIMMs CPU1: P1-DIMMA1/P1-DIMMB1
1 CPU & 4 DIMMs
1 CPU & 5~8 DIMMs
2 CPUs & 4 DIMMs
2 CPUs & 6 DIMMs
CPU1: P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1
CPU1: P1-DIMMA1/P1-DIMMB1, P1-DIMMC1/P1-DIMMD1 +
Any memory pairs in P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2 slot
CPU1 + CPU2: P1-DIMMA1/P1-DIMMB1, P2-DIMME1/P2-DIMMF1
CPU1 + CPU2: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1
2 CPUs & 8 DIMMs
2 CPUs &
8~16 DIMMs
2 CPUs & 16 DIMMs
CPU1 + CPU2: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
CPU1 + CPU2: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1
+ Any memory pairs in P1, P2 DIMM slots
CPU1 + CPU2: P1-DIMMA1/P1-DIMMB1/P1-DIMMC1/P1-DIMMD1, P2-DIMME1/P2-DIMMF1/P2-DIMMG1/P2-DIMMH1,
P1-DIMMA2/P1-DIMMB2/P1-DIMMC2/P1-DIMMD2, P2-DIMME2/P2-DIMMF2/P2-DIMMG2/P2-DIMMH2
Processors and their Corresponding Memory Modules
CPU# Corresponding DIMM Modules
CPU 1 P1-DIMMA1
CPU 2 P2-DIMME1
P1-DIMMB1
P2-DIMMF1
P1-DIMMC1
P2-DIMMG1
P1-DIMMD1
P2-DIMMH1
P1-DIMMA2
P2-DIMME2
P1-DIMMB2
P2-DIMMF2
P1-DIMMC2
P2-DIMMG2
P1-DIMMD2
P2-DIMMH2
Nodes and Corresponding Hard Drives
Description
No.
DescriptionNo.
SXB1: S-SATA 0-2/PCI-E 3.0 p1-x16 Slot supported by CPU2
P2-DIMME1/P2-DIMME2 slot
P2-DIMMF1/P2-DIMMF2 slot
Slot1: CPU2 Slot1 PCI-E 3.0 x16
JBT1: CMOS Clear
Slot2: CPU2 Slot2 PCI-E 3.0 x8
CPU2
InfiniBand (FDR) Connector (6028TP-HC1FR only)
Gigabit LAN1/LAN2 or 10G Base-T Connector (6028TP-HC1TR only)
S-SATA3: SATA DOM (Disk_On_Module) with Power-pin Connector
JSD1: SATA DOM (Device_on_Module) Power Connector
P2-DIMMH1/P2-DIMMH2 slot
P2-DIMMG1/P1-DIMMG2 slot
P1-DIMMA1/P1-DIMMA2 slot
P1-DIMMB1/P1-DIMMB2 slot
CPU1 (Install CPU1 first)
P1-DIMMC1/P1-DIMMC2 slot
P1-DIMMD1/P1-DIMMD2 slot
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
SXB2: I-SATA 0-5/PCI-E 3.0 p1-x8 Slot supported by CPU1
124
5
1
2
3
4
5
6
7
8
9
0 Slot
Low-Profile PCI-E Slot
IPMI LAN Port
Power Supply Module
UID Button
VGA Connector
InfiniBand Port (6028TP-HC1FR only)
G_LAN or 10G Base-T Connector (6028TP-HC1TR only)
USB Ports
Video adapter missing or
with faulty memory
SNK-P0057PS for CPU2
SNK-P0047PSM for CPU1
(Close to fan)
Screw #B
Screw #D
Screw #A
Screw #C
Screw #B
Screw #D
Screw #C
Screw #A
3
69 7
8
1 continuous beep System Overheat System Overheat
JBT1
P1-DIMMB2
S-SATA3
COM1
JIPMB1
FAN3
FAN4
JSD1
JTPM1
JF1
UID_LED1
BMC_HB_LED1
JPG1
JPB1
JVRM2
JVRM1
JWD1
JPL1
/CPU2 PCI-E 3.0 X16)
(CPU2 SLOT1 PCI-E 3.0 X16)
PCI-E 3.0 X8)(CPU2 SLOT2
UID SW
BATTERY
BIOS
BMC
QSFP
LAN1/LAN2
IB
10G/1G
(3.0)USB0/1
IPMI_LAN
SATA DOM+POWER
TPM/PORT80
CPU2 VRM_HS1
CPLD
P2-DIMMG1
P2-DIMMH2
P2-DIMMH1
P2-DIMMG2
P2-DIMMF2
P2-DIMME1
P2-DIMME 2
P2-DIMMF1
P1-DIMMD2
P1-DIMMD1
P1-DIMMC2
P1-DIMMC1
P1-DIMMB1
P1-DIMMA2
P1-DIMMA1
/CPU1PCI-E 3.0 X8)(I-SATA0~5
CPU2
CPU1
LAN CTRL
PCH
IB_LINK LED1
IB_ACT_LED1
(S-SATA0~2
SXB1 SXB2
Slot1 Slot2
X10DRT-P Series
Rev. 1.02
1516
171819
VGA
SXB1
SXB2
3
4
1
2
5 6 7 8 119 10
12
13
14
P t g I / IMM y es opula in RD MM LRD Memor Modul
In Suppote 5-2600v er cess Meml E 3 S ies Pro or ory rt
Type Ranks
Per
DIMM
& Data
Width
DIMM
Capacity (GB)
Speed (MT/s), Voltage (V), Slot per Channel
(SPC) and DIMM Per Channel (DPC)
1 Slot Per
Channel
2 Slots Per Channel
1DPC 1DPC 2DPC
4Gb 8Gb 1.2V 1.2V 1.2V
RDIMM SRx4 8GB 16GB 2133 MHz 2133 MHz 1866 MHz
RDIMM SRx8 4GB 8GB 2133 MHz 2133 MHz 1866 MHz
RDIMM DRx8 8GB 16GB 2133 MHz 2133 MHz 1866 MHz
RDIMM DRx4 16GB 32GB 2133 MHz 2133 MHz 1866 MHz
LRDIMM QRx4 32GB 64GB 2133 MHz 2133 MHz 2133 MHz
Hard Drive Signal
Hard Drive Fail
Power Button
LAN LED
Alert
UID
1
2
3
4
5
6
Description
No.
3
4
5
6
2
1
MB:D
MB:B
MB:C
MB:A
Node A
Node B
Node C
Node D
Motherboard Drawer Locations in the Chassis
Motherboard B
Controls HDDs B1 to B6
Motherboard D
Controls HDDs D1 to D6
Motherboard A
Controls HDDs A1 to A6
Motherboard C
Controls HDDs C1 to C6
ÌMNL-1664-QRG&Î
Note:
1. Install CPU1 first.
2. In order to support PCI-e and Zero slots, two CPUs must be installed.
ID tag
Produktspecifikationer
Varumärke: | Supermicro |
Kategori: | Server |
Modell: | SuperServer 6028TP-HC1TR |
Behöver du hjälp?
Om du behöver hjälp med Supermicro SuperServer 6028TP-HC1TR ställ en fråga nedan och andra användare kommer att svara dig
Server Supermicro Manualer
27 Oktober 2024
27 Oktober 2024
26 Oktober 2024
26 September 2024
26 September 2024
26 September 2024
25 September 2024
24 September 2024
24 September 2024
24 September 2024
Server Manualer
- Server Sony
- Server HP
- Server Toshiba
- Server Abus
- Server Acer
- Server Allnet
- Server Apc
- Server Acti
- Server Hikvision
- Server Asus
- Server SilverStone
- Server Megasat
- Server Maxdata
- Server Lenovo
- Server Black Box
- Server Tripp Lite
- Server Axis
- Server Gigabyte
- Server Nec
- Server Cisco
- Server Matrox
- Server Flir
- Server Fujitsu
- Server Digitus
- Server Kathrein
- Server Buffalo
- Server GeoVision
- Server Netgear
- Server QNAP
- Server LaCie
- Server Dell
- Server Valcom
- Server Asustor
- Server Planet
- Server ZyXEL
- Server Western Digital
- Server Intel
- Server Fantec
- Server D-Link
- Server Seagate
- Server Iomega
- Server Synology
- Server Elac
- Server Blackmagic Design
- Server ATen
- Server Conceptronic
- Server Quantum
- Server Areca
- Server SEH
- Server Ibm
- Server Provision ISR
- Server Sonnet
- Server TAIDEN
- Server Moxa
- Server Smart-AVI
- Server StarTech.com
- Server SIIG
- Server Advantech
- Server Extron
- Server KanexPro
- Server Avocent
- Server Intellinet
- Server Vimar
- Server Hanwha
- Server Ernitec
- Server Sun
- Server Raidsonic
- Server EMC
- Server AMX
- Server Rocstor
- Server Infortrend
- Server Opengear
- Server G-Technology
- Server EXSYS
- Server Raritan
- Server Chenbro Micom
- Server Mr. Signal
- Server Atlantis Land
- Server C2G
- Server Lantronix
- Server Promise Technology
- Server HGST
- Server IStarUSA
- Server NETSCOUT
- Server Mobotix
- Server Origin Storage
Nyaste Server Manualer
26 Oktober 2024
26 Oktober 2024
24 Oktober 2024
24 Oktober 2024
21 Oktober 2024
18 Oktober 2024
18 Oktober 2024
17 Oktober 2024
17 Oktober 2024
16 Oktober 2024