Supermicro SuperServer SYS-120H-TNR Bruksanvisning

Supermicro Server SuperServer SYS-120H-TNR

Läs nedan 📖 manual på svenska för Supermicro SuperServer SYS-120H-TNR (1 sidor) i kategorin Server. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/1
LBL-2392-B-QRG
Board Layout
SuperServer 120H-TNR Quick Reference Guide
Rev 1.0
Caution and Product Resources
IMPORTANT: See installation instructions and
safety warning before connecting system to
power supply.
http://www.supermicro.com/about/policies/
safety_information.cfm
SAFETY INFORMATION:
Always be sure all power supplies for this system have
the same power output. If mixed power supplies are
installed, the systemwill not operate.
CAUTION:
To reduce risk of electric shock/damage to
equipment, disconnect power from server by
disconnecting all power cords from electrical
outlets. If any CPU socket empty, install
protective plastic CPU cap.
WARNING:
CAUTION:
This unit has redundant power sources.
Please disconnect all the power cords before servicing.
For more information go to:
http://www.supermicro.com/support
PRODUCT RESOURCES:
6 5
5 6
CPU1 CPU2
1
2
3
1
2
3
CPU1 CPU2
4
4
12 NVMe 8 NVMe 4 NVMe
21
2 5
56
3
3
6
4
4
1
CPU1 CPU2
2
2
2
21 1
1
1 1
1
LBL-2392-T-QRG Rev 1.0
12 SAS/SATA 8 SAS/SATA 4 SAS/SATA
http://www.supermicro.com
Front View
Description DescriptionNo.
1
2
3
No.
4
5
6
USB 3.0 Port
Front Control Panel
Service/Asset Tag with System Serial
Number and BMC Unique Password
Drive Bay 3Drive Bay Drive Bay Drive Bay Drive Bay Drive Bay 1 5 7 9 11
8 Drive Configuration
12 Drive Configuration
Front IO Configuration
1 2
Drive Bay 0 Drive Bay Drive Bay Drive Bay 6 8 10Drive Bay 2
4 5 6
3
Drive Bay 4
1
Cable Part Number
Drive Bay 0-1
2
Drive Bay 2-3
3
Drive Bay 4-5
4
Drive Bay 6-7
5
Drive Bay 8-9
6
Drive Bay 10-11
CBL-SAST-1213LP-85
CBL-SAST-1213LP-85
Not Used
CBL-SAST-1212LP-85
CBL-SAST-1212LP-85
Not Used
CBL-SAST-1293LP-85
CBL-SAST-1233LP-85
Not Used
CBL-SAST-1238LP-85
CBL-SAST-1214LP-85
Not Used
CBL-SAST-1214LP-85
Not Used
CBL-SAST-1214LP-85
CBL-SAST-1211LP-85
Not Used
CBL-SAST-1211LP-85
Drive Configuration
12 NVMe
8 NVMe
4 NVMe
1
Cable Part Number
Drive Bay 0-7
2
Drive Bay 8-11
CBL-SAST-1273LP-100
CBL-SAST-1273LP-100
Not Used
CBL-SAST-1262LP-100
Not Used
CBL-SAST-1262LP-100
Drive Configuration
12 SAS/SATA
8 SAS/SATA
4 SAS/SATA
Dedicated BMC LAN/USB/VGA Ports
Slot A2, AIOM/OCP 3.0 Networking Slot (CPU2)
Slot A1, AIOM/OCP 3.0 Networking Slot (CPU1)
3. Put processor heatsink module into MB.1. Put processor into bracket –
attention to the lineup Pin and
key on both processor and carrier. B
Processor Carrier Assembly
2. Put processor carrier module into HS.
T30 Torx
Driver
Use a torque
of 12lbf-in
AB, C, D: Peek Nut
1, 2, 3, 4: Rotating Wire
a, b, c, d: Threaded Fastener
3 Rotating
Wire
C
Rotating 1
Wire
Peek Nut
A
d
a
b
4 Rotating Wire
Threaded
Fastener
Heatsink
CPU tSocke
1
2A
B
Latch
a
Latch
CPU Key
(on the processor)
CPU Key
(on the carrier)
CPU Key (on the
processor)
CPU Key (on
the carrier) b
a
B
D
b
c
d
Processor Carrier Assembly (with CPU
mounted on the Processor Clip)
Pin1
A
D
2
c
Peek Nut
(Unlatched) (latched)
Rotating Wire
C
CPU Installation
Storage AOC Drive Bay Cable Routing
System Information
Each system comes with a unique
default password for the ADMIN user.
This can be found on a sticker on the
motherboard and a sticker underneath
the service tag on chassis.
If necessary, the password can be
reset by the Supermicro IPMICFG tool.
For more information, please visit
https://www.supermicro.com/en/solutions/
management-software/bmc-resources
S/N Label
Pull-out tag with BMC
unique password and
Serial Number Label
underneath.
PULL
BMC: XXXXXXXXXXXX
PWD: AMBWODMRG T
S/N: S123456XXX0123
BMC: XXXXXXXXXXXX
PWD: AMBWODMRGT
S/N: S123456XXX0123
NVMe Drive Bay Cable Routing
Memory Support
* Unbalanced, not recommended.
Note: Numbers of DIMM not listed are not supported
CPUs/DIMMs Memory Population Sequence
2 CPUs & 2 DIMMs
2 CPUs & 4 DIMMs
2 CPUs & 6 DIMMs*
2 CPUs & 8 DIMMs
2 CPUs & 10 DIMMs*
2 CPUs & 12 DIMMs
2 CPUs & 14 DIMMs*
2 CPUs & 16 DIMMs
2 CPUs & 18 DIMMs*
2 CPUs & 20 DIMMs*
2 CPUs & 22 DIMMs*
2 CPUs & 24 DIMMs
2 CPUs & 28 DIMMs*
2 CPUs & 32 DIMMs
CPU1: P1-DIMMA1
CPU2: P2-DIMMA1
CPU1: P1-DIMMA1/P1-DIMME1
CPU2: P2-DIMMA1/P2-DIMME1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1
CPU2: P2-DIMMA1/P2-DIMME1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1/P2-DIMMD1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1/P2-DIMMD1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2/P1-DIMMB2/P1-DIMMF2/P1-DIMMD2/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2/P1-DIMMB2/P1-DIMMF2/P1-DIMMD2/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1/P2-DIMMD1/P2-DIMMH1
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2/P1-DIMMB2/P1-DIMMF2/P1-DIMMD2/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1/P2-DIMMA2/P2-DIMME2/
P2-DIMMC2/P2-DIMMG2/P2-DIMMB2/P2-DIMMF2
CPU1: P1-DIMMA1/P1-DIMME1/P1-DIMMC1/P1-DIMMG1/P1-DIMMB1/P1-DIMMF1/P1-DIMMD1/P1-DIMMH1/
P1-DIMMA2/P1-DIMME2/P1-DIMMC2/P1-DIMMG2/P1-DIMMB2/P1-DIMMF2/P1-DIMMD2/P1-DIMMH2
CPU2: P2-DIMMA1/P2-DIMME1/P2-DIMMC1/P2-DIMMG1/P2-DIMMB1/P2-DIMMF1/P2-DIMMD1/P2-DIMMH1/
P2-DIMMA2/P2-DIMME2/P2-DIMMC2/P2-DIMMG2/P2-DIMMB2/P2-DIMMF2/P2-DIMMD2/P2-DIMMH2
Rear View
DescriptionNo.
1
2
3
4
5
6
7
8
Redundant Power Supplies
Dedicated BMC LAN Port*
Slot 1, PCI-E 4.0 p1-x16 Slot (CPU2)
Slot 2, PCI-E 4.0 p1-x16 Slot (CPU1)
Slot 3, PCI-E 4.0 p1-x16 Slot (CPU2)
Slot A1, AIOM/OCP 3.0 Networking
Slot (CPU1)
VGA port
2x USB 3.0 Ports*
DescriptionNo.
9
Power Supply LED Solid Green
Power Supply LED Blinking Green
Power Supply LED Solid Green
Power Supply LED Blinking Green
A valid power source is connected to the
PSU and the PSU is operational
(Scenario 1) Power source to the PSU is
disconnected or invalid but a second
PSU is operational.
(Scenario 2) PSU failure and the PSU is
not operational.
PSU is in standby state
(12VSB standby power only).
A PSU warning event occurred and the
PSU is still operational.
21 3
9 8 7 6
4 5
* Relocated to the front of the chassis in
Front IO configuration
Default Setting
Open (Normal)
Jumper
JBT1
Connector
BT1
FAN1 ~ FAN8
JAIOM1
JF3_JIPMB1
JFP1
JFP2
JGPW1~5
JIO1
JL1
JNCSI1
JNVI2C1
JNVVPP1
JPCIE1, JPCIE4
JPCIE2A1, JPCIE2B1,
JPCIE3A1,JPCIE3B1,
JPCIE5A1, JPCIE5B1
JPRG1
JPWR1, JPWR4
JRSI2C1
JS1
JTPM1
JUID1
JUSB3
JVRM1
M.2-H1/M.2-H2
P1_NVME0/P1_
NVME1/P2_
NVME0/P2_NVME1
PSU1~2
VROC (JRK1)
Description
CMOS clear
Description
Onboard CMOS battery
6-pin system cooling fan headers
The Supermicro® Advanced I/O Module (AIOM) slot
6-pin BMC external I²C header (for an BMC card)
Front control panel header
Front VGA header
8-pin power connector
Low-profile slimSAS 8x I/O connector
Chassis intrusion header
NC-SI (Network Controller Sideband Interface) connector
NVMe SMBus (I²C) headers used for PCIe hot-plug
SMBus clock and data connections
CPU VPP bus header for backplane NVMe riser card device
CPU PCIe 4.0 p1-x16 slots
CPU PCIe 4.0 p1-x8 slots
Complex Programmable Logical Device (CPLD) header
6-pin power connector
SMBus header for riser card
I-SATA 0~7 connector
Trusted Platform Module/Port 80 Connector
Multi-purpose UID switch and reset switch
USB 3.0 header (supports two USB 3.0 ports)
VRM SMB clock to BMC
M.2 PCIe 3.0 p1-x2 or SATA 3.0 hybrid slots (Supports
M-Key 2280and 22110) supported by PCH
Power supply unit connectors
Intel VROC RAID key header for NVMe SSD
NVMe PCIe 4.0 p1-x4 ports (Note: When installing an
NVMe device on a motherboard, please be sure to
connect JNVME0 first for your system to work properly.)
A37
X12DHM
REV:1.02A
DESIGNED IN USA
BIOS LICENSE
BAR CODE
BMC CODE
MH1
MH9
JUSB3
JUID1
JL1
JRSI2C1 JNVI2C1 JNVVPP1
JF3_JIPMB1
P1_NVME1
JS1
JPCIE2B1
P2_NVME1
P2_NVME0
JIO1
P1_NVME0
JPCIE5A1JPCIE5B1
JPCIE2A1
JPCIE3A1JPCIE3B1
PSU1PSU2
M.2-H2 M.2-H1
BT1
JFP2
LED1
LED2
LEDM1
JFP1
JRK1
JPFR1
JPCIE4
JAIOM1
JPRG1
JNCSI1
MH15
JGPW4
JGPW3
JGPW1
JGPW2 JGPW5
JVRM1
FAN9
JPWR4
JPWR1
JAIOM2SB1
PCH
BMC
JBT1
JPCIE1
MH17
FAN10
MH10
MH5
MH11
MH2 MH3 MH4
MH13
MH12
LE DBM C
U ID- LE D
LE DPWR
P1_PE1 7-0P1_PE1 15-8
P1_PE0 0-15
P2_PE2 0-7P2_PE2 8-15
P2_PE1 15-0
P2_PE0 8-15
P2_PE0 0-7
P1_PE3 8-15
P1_PE3 0-7
P2_PE3 8-15
P2_PE3 0-7
CPU 1 PCI- E 4.0 X8
CPU 1 PCI- E 4.0 X8
CPU 2 PCI- E 4.0 X8
CPU 2 PCI- E 4.0 X8
CPU 1 PCI- E 4.0 X8
P1_PE2 1CPU 1 PCI 4.0 X16
CPU 1 PCI- E 4.0 X8
U SB 2/3 (3.0)
CPU 1 PCI- E 4.0 X16
I-SAT A 0
CPU 2 PCI- E 4.0 X8CPU 2 PCI- E 4.0 X8
CPU 2 PCI- E 4.0 X16
CPU 2 PCI- E 4.0 X8CPU 2 PCI- E 4.0 X8
FAN8 FAN7
P1-DI M M F1P1-DI M M F2
P1-DI M M E1
P1-DI M M H 1
P1-DI M M E2
P1-DI M M H 2P1-DI M M G1
P1-DI M M G2
P1-DI M M C2
P1-DI M M D2P 1-DI M M C1
P1-DI M M A1
P1-DI M M D1
P1-DI M M A2
P1-DI M M B2
P1-DI M M B1
FAN6
FAN5
FAN4
P2-DI M M E2
P2-DI M M E1
JTPM1: TPM/PO RT80
FAN3
P2-DI M M F2
P2-DI M M F1
P2-DI M M H 2P2-DI M M H 1
CPU2
P2-DI M M G1
P2-DI M M G2
P2-DI M M D1
P2-DI M M A2
P2-DI M M D2
P2-DI M M C1
P2-DI M M C2
JRK1
P2-DI M M B1
P2-DI M M B2
P2-DI M M A1
FAN2 FAN1
CPU1
MH16
JTPM1
JNSCI1
JGPW4
JPCIE1
JPCIE2A1
JFP2
JNVI2C1
JNVVPP1
JRSIC1
P1_NVME1
LED1
LED2
JL3_JIPMB1
JFP1
FAN8
FAN7
FAN6
FAN5
FAN4
FAN3
FAN2
FAN1
P1-DIMMB1
P1_NVME0
P2_NVME1
P1-DIMMG2
P1-DIMMG1
P1-DIMMH2
P1-DIMMH1
P1-DIMME2
P1-DIMME1
P1-DIMMF2
P1-DIMMF1
P1-DIMMC2
P1-DIMMB2
P1-DIMMA1
P1-DIMMA2
P1-DIMMD1
P1-DIMMD2
P1-DIMMC1
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMME2
P2-DIMMH1
P2-DIMMH2
P2-DIMMG1
P2-DIMMG2
P2-DIMMC2
P2-DIMMC1
P2-DIMMD2
P2-DIMMD1
P2-DIMMA2
P2-DIMMA1
P2-DIMMB2
P2-DIMMB1
P2_NVME0
LEDM1
JUID1
JL1
JBT1
JTPM1
BT1
JPRG1
JPFR1
PSU2
JRK1
JVRM1
JAIOM2SB1
M.2-H1
JPCIE5A1
JPCIE5B1
JGPW5
PSU1
JGPW2
JGPW1
JGPW3
JCOMDBG1_
JWD1
JPWR1
JPWR4
JPCIE3A1
JAIOM1
M.2-H2
JPCIE4
JIO1
JPCIE2B1
JUSB3
JS1
JPCIE3B1

Produktspecifikationer

Varumärke: Supermicro
Kategori: Server
Modell: SuperServer SYS-120H-TNR

Behöver du hjälp?

Om du behöver hjälp med Supermicro SuperServer SYS-120H-TNR ställ en fråga nedan och andra användare kommer att svara dig




Server Supermicro Manualer

Server Manualer

Nyaste Server Manualer