Sven VR-L600 Bruksanvisning

Läs nedan 📖 manual på svenska för Sven VR-L600 (5 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/5
www.sven.fi
USER MANUAL
Automatic Voltage Regulator
VR-L600
VR-L100
VR-L1500
ENG
2
Automatic Voltage Regulator
Congratulations on your purchase of Sven Automatic Voltage Regulator!
Please read this Operation Manual before using the unit and retain this Operation Manual inasafe
place for future reference.
COPYRIGHT
© SVEN PTE. LTD. Version 2.0 (02.06.2022).
This Manual and information contained in it are copyrighted. All rights reserved.
TRADEMARKS
All trademarks are the property of their legal holders.
NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted eorts to make this Manual more exact, some discrepancies may occur.
Theinformation in this Manual is given on «as is» terms. The author and the publisher do notbear
any liability to a person or an organization for loss or damage which has arisen from the infor-
mation contained in this Manual.
CONTENTS
ENG 2 ...............................................................................................................................................
1. UNPACKING 2 ............................................................................................................................
2. PACKAGE CONTENTS 2 ...............................................................................................................
3. SAFETY PRECAUTIONS 3 ............................................................................................................
4. TECHNICAL DESCRIPTION 3 ......................................................................................................
5. INSTALLATION AND OPERATION GUIDE 3 ...............................................................................
6. TROUBLESHOOTING 4 ...............................................................................................................
7. TECHNICAL SPECIFICATIONS 5 ..................................................................................................
RUS 6 ................................................................................................................................................
1. UNPACKING
• Unpack the device carefully. Make sure there are no accessories left in the box. Check up
thedevice for damage; if the product was damaged during transportation, address the rm
which carried out the delivery; if the product functions incorrectly, address the dealer at once.
• Shipping and transportation equipment is permitted only in the original container.
• Does not require special conditions for realization.
• Dispose of in accordance with regulations for the disposal of household and computer equipment.
2. PACKAGE CONTENTS
• Automatic Voltage Regulator1 pc
• Operation Мanual — 1 pc
• Warranty card1 pc
Technical support is on www.sven..
ENG
4
Automatic Voltage Regulator
• Before installing the AVR, please make sure that total power of all consumers is lower than
AVR power. Besides, take into account the starting load and power factor of consumers, it is
necessary to apply power margin factor of 1.2–1.5; it should be 1.5–2 for such equipment as air
conditioners, fridges, etc.
• Connect the necessary equipment to the power outlet (s) of the stabilizer.
• Connect the regulator to the power network of 230 V.
• Turn on the stabilizer. When the built-in LED lights up the key, and LED light up: for a short
period to test, “Regulating” and “Delaying/Protection”, constantly, “Working”.
• When the self-test is complete LED “Delaying/Protection” will go out and voltage connection
to the output receptacles will happen. If the LED “Delaying/Protection” at the end of the test did
not go out, it is prohibited to operate the regulator to eliminate the problem.
• “Regulating” LED will light when the regulator to increase or decrease in the input voltage.
• In case of overload or short circuit the thermal fuse is ready installed on the rear wall is trig-
gered. Turn on the stabilizer after removing the cause of the overload by pressing the power
button.
• When voltage input is more than 285 V or below 184 V regulator will disconnect the load. “De-
laying/Protection” LED will light up.
• “Delaying/Protection” indicator will light up in case of overheating auto-transformer, protec-
tion will work. The load deenergises. After cooling down auto-transformer load power is re-
stored automatically.
6. TROUBLESHOOTING
Problem Cause Solution
The stabilizer does not turn
on voltage.
1. Switch is o.
2. There is no voltage
inthemains socket.
3. Excessive load is connected.
Triggering of protection fuse.
1. Turn on the switch.
2. Make sure there is input
voltage.
3. Disconnect a part of load.
Turn on the protective fuse.
Stabilizer turned on wherein
thelight does not go out
“Delaying/Protection”
andthere is no output
voltage.
1. Test curcuit crash.
2. Overheating
oftheautotransformer.
1. Switch the AVR o
andonagain. If the problem
is not solved, address
aservice center.
2. Wait until the product cools
down.
Voltage regulator keeps
clicking with constant
blinking of“Regulating” LED.
Input voltage is very unstable. It is normal. The AVR
isregulating the output
voltage.
Stabilizer disabled load.
“Delaying/Protection”
andRegulating”
indicatorsare on.
The input voltage is too
low/high.
When the input voltage
reaches 184–285 V, the AVR
will resume its operation.
If none of the above methods can solve the problem, please seek professional advice at your near-
est service center. Never attempt to repair the product yourself.