Velleman DCM330 Bruksanvisning
Velleman
Multimeter
DCM330
Läs nedan 📖 manual på svenska för Velleman DCM330 (29 sidor) i kategorin Multimeter. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/29
DCM330
DIGITAL CLAMP MULTIMETER
DIGITALE STROOMTANG
PINCE AMPÈREMÉTRIQUE NUMÉRIQUE
PINZA AMPERIMÉTRICA DIGITAL
DIGITALE STROMZANGE
MULTIMETRO DIGITALE CON PINZA AMPEROMETRICA
USER MANUAL
GEBRUIKERSHANDLEIDING
NOTICE D’EMPLOI
MANUAL DEL USUARIO
BEDIENUNGSANLEITUNG
MANUALE UTENTE
DCM330_v2 VELLEMAN
2
DCM330 – DIGITAL CLAMP MULTIMETER
1. Introduction
To all residents of the European Union
Important environmental information about this product
This symbol on the device or the package indicates that disposal of the
device after its lifecycle could harm the environment. Do not dispose of the
unit (or batteries) as unsorted municipal waste; it should be taken to a
specialized company for recycling. This device should be returned to your
distributor or to a local recycling service. Respect the local environmental rules.
If in doubt, contact your local waste disposal authorities.
Thank you for choosing Velleman! Please read the manual thoroughly before bringing this
device into service. If the device was damaged in transit, do not install or use it and contact
your dealer.
2. Safety Instructions
• Damage caused by disregard of certain guidelines in this manual is not covered by
the warranty and the dealer will not accept responsibility for any ensuing defects or
problems.
• Switch off the meter when not in use.
• Do not exceed the maximum allowable input range of any function.
• Do not apply voltage to the meter when the resistance function is enabled.
• Set the function switch to the appropriate position before measuring.
• Do not switch to current/resistance modes when measuring a voltage.
• Do not measure current on a circuit whose voltage exceeds 240V.
• Always disconnect the test leads from the circuit under test when changing ranges
with the selector switch.
• Note that damage caused by user modifications to the device is not covered by the
warranty.
• Keep the device away from children and unauthorised users.
3. General Guidelines
• Improper use of this meter can cause damage, shock or injury. Read and understand
this manual before operating this meter.
• Always remove the test leads before replacing the battery.
• Inspect the condition of the test leads and the meter for any damage before operating.
Repair any damage or replace before use.
• Use great care when making measurements of voltages higher than 25VAC RMS or
35VDC. These voltages are considered hazardous.
• Remove the battery if the meter is to be stored for long periods.
• Always discharge capacitors and remove power from the device under test before
performing diode, resistance or continuity tests.
• Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical outlets. Other means should be
used to ensure that the terminals are not live.
Refer to the manual for further information.
Double insulation.
Hazardous voltages may be present under normal use.
DCM330_v2 VELLEMAN
3
• If the equipment is used in a manner not specified in this manual, the protection
provided by the equipment may be impaired.
Input Limits
Function Maximum Input
A
AC 400
A
VDC, VAC 600V DC/AC
Resistance, diode, continuity 250V DC/AC
4. Description
1. clamp meter
2. clamp opening lever
3. rotary selector switch
4. LCD
5. MAX button
6. data hold button
7. mode selection button
8. range selection button
9. backlight button
10. COM input jack
11. V/Ω jack
12. battery cover
AC DC
A
C/DC current measurement
minus sign
1.8.8.8 measurement reading
AUTO auto range mode (except for A ranges)
MAX MAX hold mode
diode test
audible continuity
HOLD data hold mode
BAT low battery icon
°C °F m
V A K M
Ω
measurement units
5. Technical Specifications
Clamp Size opening 23mm (14/16”)
Diode Test Current 0.3mA typical; open circuit voltage 1.5VDC
Continuity Check threshold < 120Ω; test current < 1mA
Low Battery Indication “ ” is displayed
Overrange Indication “ ” is displayed
Measurement Rate 2 per second, nominal
Input Impedance 7.8M Ω (V DC and AC)
Produktspecifikationer
Varumärke: | Velleman |
Kategori: | Multimeter |
Modell: | DCM330 |
Behöver du hjälp?
Om du behöver hjälp med Velleman DCM330 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Velleman Manualer
5 Oktober 2024
5 Oktober 2024
5 Oktober 2024
22 September 2024
16 September 2024
27 Augusti 2024
20 Augusti 2024
10 Augusti 2024
4 Augusti 2024
1 Augusti 2024
Multimeter Manualer
- Multimeter Abus
- Multimeter Alecto
- Multimeter Appa
- Multimeter Amprobe
- Multimeter Amiko
- Multimeter Silverline
- Multimeter Ferm
- Multimeter Milwaukee
- Multimeter Elro
- Multimeter EMOS
- Multimeter Extech
- Multimeter Tacklife
- Multimeter Metrix
- Multimeter Benning
- Multimeter Voltcraft
- Multimeter Somogyi
- Multimeter Steren
- Multimeter Kyoritsu
- Multimeter Flir
- Multimeter Maxwell
- Multimeter Digitus
- Multimeter Testboy
- Multimeter Hager
- Multimeter TFA
- Multimeter Clas Ohlson
- Multimeter Powerfix
- Multimeter Owon
- Multimeter Fluke
- Multimeter Basetech
- Multimeter Etekcity
- Multimeter Greenlee
- Multimeter Högert
- Multimeter REV
- Multimeter Keithley
- Multimeter Monacor
- Multimeter Metrel
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Brandson
- Multimeter GW Instek
- Multimeter Skandia
- Multimeter Elma
- Multimeter Uni-T
- Multimeter PeakTech
- Multimeter Sonel
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Gossen Metrawatt
- Multimeter Rigol
- Multimeter PCE Instruments
- Multimeter CEM
- Multimeter Joy-it
- Multimeter Klein Tools
- Multimeter Aim TTi
- Multimeter Wiha
- Multimeter Sanwa
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nyaste Multimeter Manualer
23 Oktober 2024
21 Oktober 2024
18 Oktober 2024
18 Oktober 2024
17 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024